DOWNLOAD Panasonic CS-PC9CKH / CU-PC9CKH / CS-SC9CKH / CU-PC9CKH / CS-PC12CKH / CU-PC12CKH / CS-SC12CKH / CU-PC12CKH Service Manual ↓ Size: 10.71 MB | Pages: 76 in PDF or view online for FREE

Model
CS-PC9CKH CU-PC9CKH CS-SC9CKH CU-PC9CKH CS-PC12CKH CU-PC12CKH CS-SC12CKH CU-PC12CKH
Pages
76
Size
10.71 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-pc9ckh-cu-pc9ckh-cs-sc9ckh-cu-pc9ckh-cs-pc12ckh.pdf
Date

Panasonic CS-PC9CKH / CU-PC9CKH / CS-SC9CKH / CU-PC9CKH / CS-PC12CKH / CU-PC12CKH / CS-SC12CKH / CU-PC12CKH Service Manual ▷ View online

10 Operating Instructions
Outdoor Unit
PRODUCT OVERVIEW
Your device can...
1
High
- Operate in High Fan Speed
Med
- Operate in Medium Fan Speed
Low
- Operate in Low Fan Speed
OFF
- Stop all operations
Operation Switch
- Red Colour Indicator will be shifted to the
respective position when operation mode changed.
Upward - High Temp. (less cool)
Downward - Low Temp. (more cool)
Cooling Temperature setting :-
16˚C ~ 30˚C
Indoor Unit
1.1
«AIR SWING»
1.3
1.2
«POWER ON»
Air intake
Air outlet
Piping, connecting cable
Cooling
Dehumidifying
 Air Circulation
Filters under front panel, see page 32
Direction louver
Wired Remote Control
CS-SC9CKH, CS-SC12CKH
Power OFF/ON
Cooling temperature setting control
Air Swing selection button
ON
- Swing automatically
OFF
- Stop the operation of the Air Swing
CS-SC9CKH, CS-SC12CKH
Indicator
29
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
31
31
30
see page
31
30
To start / stop
Operation automatically
Set TEMPERATURE
30
Press to START                     >>
Press again to STOP     
      >>
Open front panel
Switch OFF/ON of the device
If Remote Control malfunctions /is misplaced....
see page
1
2
3
Under front panel
AUTO-Mode only
Wireless Remote Control
Vertical direction
Horizontal direction Adjust manually
Fan Speed (air volume)
!
Select Fan Speed
«TIMER
»
«POW
ER ON
»
Select
CONFIRM SETTING
Function
Example
Press to Select Delay hour
Press once, ON/OFF Delay hour operation will activate
after reaching the setting number of hours (1-12)
TIMER Operation
Operasi PEMASA
Direction / volume
Select automatic / manual
Swing automatically
Indicator & Auto operation button
Fluorescent lights may interfere with signal transmission
Memory reset!
Air Flow
Delay OFF Timer
Stop after 5 hours
Press
1X
Delay ON Timer
Start after 2 hours
Press
Press once again to cancel
CANCEL SETTING
Start before «ON» time
Delay OFF & ON Timer Stop after 3 hours then start
after 4 hours
Press
COOL / DRY : 15 min.
NOTES
• Press ON/OFF button will cancel the setting
• Press SET/CANCEL button to activate again the
previous setting
Delay ON & OFF Timer Start after 10 hours then stop
after 7 hours
Press
2X
3X
4X
CS-PC9CKH, CS-PC12CKH
Select MODE
TIMER functions
Select air flow direction
1.4
Press button
30
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Additional comfort
Hi  
= +2˚C
Lo  
-2˚C
      
= standard
Lo-...-Hi
Select...
Select...
Select...
Select...
OPERATION
TROUBLE-
SHOOTING
Find on page
PREPARATIONS
SAFETY
PRECAUTIONS
HELPFUL
INFORMATION
35
32
33
34
Switch on
START
Set temperature
Automatic Internal Function
Press button
Switch off
STOP
According to the room temperature the system automatically chooses
Choose the right temperature to be comfortably cool!
Very gentle cooling and dehumidifying operation
Automatic
Dehumidifying
min. 16˚C
max. 30˚C
Recommended : Room temperature
AUTO
COOL
DRY
Fan operation to circulate air in the room
Air circulation
FAN
Recommended:
min. 16˚C
max. 30˚C
~26...28˚C
-(1~2)˚C
Cooling
Room temperature
Set temperature
low speed
CS-PC9CKH, CS-PC12CKH
*
* automatic during dehumidifying (DRY)
31
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
1
2
1
2
Indoor Unit
Filters
Wipe gently
Filter cleaning see below
CARE & CLEANING
every 2 weeks
DIRTY FILTERS cause: unpurified air, low cooling capacity, foul odours, higher energy consumption!
!
Soaps Neutral household detergents
Air filters
Vacuum
Damaged –> replace!
?
Wash
Dry
Remove
Scouring powder
Benzene / Thinner
«FRONT»
 pH7 )
Front Panel
Reinstall
Remove
Wash gently...
: CWD001047
HELPFUL INFORMATION
Automatic Operation
If remote control malfunctions / is misplaced
Better
performance!
Save cost
*
Built-in surge protection, BUT UNPLUG in case of very strong
lightning!
Thunder / Lightning
Random restart automatically
Power Failure
When power resume...
Restored
3 - 4 Min.
TIMER
MODE
AIRFLOW direction
Deleted -> set again!
CS-PC9CKH, CS-PC12CKH
see page 30
see page 31
Use....
                     TIMER!
CS-PC9CKH, CS-PC12CKH
Close
*
*
Vacuum
Dry
COOL + (1˚C)
CS-PC9CKH, CS-PC12CKH
TEMP
*
Part No.
Reinstal
32
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Page of 76
Display