Panasonic CS-PC9CKH / CU-PC9CKH / CS-SC9CKH / CU-PC9CKH / CS-PC12CKH / CU-PC12CKH / CS-SC12CKH / CU-PC12CKH Service Manual ▷ View online

Time Delay Safety Control
Starting Current Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
     • 
• 
• 
• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
     • 
• 
• 
• During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
     • 
• 
• 
• The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
off, it stops for 6 minutes.
     • 
• 
• 
• Once the compressor stops, it will not start for 3 minutes during Cooling operation.
     • 
• 
• 
• Same as Starting Current Control for Cooling Mode operation.
     • 
• 
• 
• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
     • 
• 
• 
• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
     • 
• 
• 
• Fan speed off and on at Lo- speed.
21
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Soft Dry Operation Time Diagram
22
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Air Circulation Mode Operation Time Diagram
Standard for Determining Operation Mode
8.3. Air Circulation Mode Operation
     • 
• 
• 
• Fan Operation only. Indoor fan speed selection by remote control and setting refer to Indoor Fan speed control.
8.4. Automatic Mode Operation
     • 
• 
• 
• Indoor fan operates at SLo fan speed for 20 seconds.
     • 
• 
• 
• After judging indoor air temperature, the operation mode is determined and operation continued at the mode determined.
     • 
• 
• 
• After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation includes
Cooling mode operation.
     • 
• 
• 
• Room temperature adjustment.
The following are added to the setting temperature specified as above.
     • 
• 
• 
• The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX1 at indoor
electronic controller.
8.5. Random Auto Restart Control
     • 
• 
• 
• If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when the
power is resumed.
It will start with previous operation mode and airflow direction.
     • 
• 
• 
• Restart time is decided randomly using 4 parameter:-
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
     • 
• 
• 
• This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
23
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
8.6. Indoor Fan Speed Control
     • 
• 
• 
• Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
     • 
• 
• 
• Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote
control.