Vertical Airflow Direction Auto-Control
     • 
• 
• 
• When set an Airflow Direction Auto-Control with Air Swing
button at the remote control, the louver swings up and down
as shown in the diagram.
     • 
• 
• 
• The louver does not swing when the Indoor Fan Motor
stops during operation at the upper limit.
     • 
• 
• 
• When stopped with remote control, the discharge vent is
reset, and stopped at the closing position.
8.7. Vertical Airflow Direction Control
1. There is no swinging while indoor fan motor is stopped during Cooling and Soft Dry operation.
8.8. Delay ON Timer Control
     • 
• 
• 
• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
     • 
• 
• 
• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
     • 
• 
• 
• For Automatic mode, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.9. Remote Control Signal Receiving Sound
     • 
• 
• 
• Long beep sound will be heard when:-
     − 
− 
− 
− Stopping the Air Conditioner using ON/OFF switch.
     • 
• 
• 
• Short beep sound will be heard for others.
     • 
• 
• 
• To switch off the beep sound:-
Press the “Automatic Operation Button” continuously for 10 seconds or more (“beep” “beep” will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the “Automatic Operation Button” has been pressed the Automatic operation will be activated.
If you do not require this operation, you may change it by using the remote control.
25
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Cooling in operation according to Remote Control setting.
Time Delay Safety Control (3 minutes)
7 minutes Time Save Control
Starting Current Control
Anti-Freezing Control
     • 
• 
• 
• If the temperature of the indoor heat exchanger falls
continuously below 2°C for 4 minutes or more, the
compressor turns off to protect the indoor heat exchanger
from freezing. The fan speed setting remains the same.
     • 
• 
• 
• Compressor will restart again when the indoor heat
exchanger temperature rises to 10°C (Recovery).
3 minutes waiting of Time Delay Safety Control is valid for
Cooling Operation.
Compressor Reverse Rotation Protection Control
9 Operation Details (CS-SC9CKH & CS-SC12CKH)
9.1. Cooling Mode Operation
     • 
• 
• 
• When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
     • 
• 
• 
• When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
     • 
• 
• 
• The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor
ON temperature and OFF temperature.
     • 
• 
• 
• When the compressor outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will operate 1.6
second later.
     • 
• 
• 
• If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
indoor heat exchanger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid)
! T = Intake air temperature - Indoor heat exchanger temperature
This is to protect reverse rotation of the compressor when there is an instantaneous power failure.
26
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Cooling Operation Time Diagram
9.2. Random Auto Restart Control
     • 
• 
• 
• If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when the
power is resumed.
It will start with previous operation mode and airflow direction.
     • 
• 
• 
• Restart time is decided randomly using 4 parameter:-
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
     • 
• 
• 
• This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
27
CS-PC9CKH CU-PC9CKH / CS-SC9CKH CU-PC9CKH / CS-PC12CKH CU-PC12CKH / CS-SC12CKH CU-PC12CKH
Vertical Airflow Direction Auto-Control
     • 
• 
• 
• When set an Airflow Direction Auto-Control with Air Swing
button at the remote control, the louver swings up and down
as shown in the diagram.
     • 
• 
• 
• The louver does not swing when the Indoor Fan Motor
stops during operation at the upper limit.
     • 
• 
• 
• When stopped with remote control, the discharge vent is
reset, and stopped at the closing position.
9.3. Indoor Fan Speed Control
     • 
• 
• 
• Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote
control.
9.4. Vertical Airflow Direction Control
1. There is no swinging while indoor fan motor is stopped during Cooling operation.