DOWNLOAD Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Service Manual ↓ Size: 13.85 MB | Pages: 100 in PDF or view online for FREE

Model
CS-E18CKE CU-E18CKE CS-E21CKE CU-E21CKE
Pages
100
Size
13.85 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-e18cke-cu-e18cke-cs-e21cke-cu-e21cke.pdf
Date

Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Service Manual ▷ View online

 1 
Features 
2
 2 
Functions 
3
 3 
Product Specifications 
6
 4 
Dimensions 
10
 5 
Refrigeration Cycle Diagram 
12
 6 
Block Diagram 
13
 7 
Wiring Diagram 
14
 8 
Operation Details 
15
 8.1. 
BASIC FUNCTION 
15
 8.2. 
Protection Control Features 
32
 9 
Operating Instructions 
44
 10 Installation And Servicing Air Conditioner Using R410A 
52
 10.1. OUTLINE 
52
 10.2. TOOL FOR INSTALLING / SERVICING REFRIGERANT
PIPING 
53
 10.3. REFRIGERANT PIPING WORK 
57
CS-E18CKE CU-E18CKE
CS-E21CKE CU-E21CKE
 10.4. INSTALLATION, TRANSFERRING, SERVICING 
59
 11 Installation Instructions 
63
 11.1. Safety Precautions 
63
 11.2. INDOOR UNIT 
66
 11.3. OUTDOOR UNIT 
69
 12 Servicing Information 
72
 12.1. Troubleshooting 
72
 12.2. Breakdown Self Diagnosis Function 
74
 12.3. Remote Control 
76
 12.4. Indoor Electronic Controllers Removal Procedures 
77
 12.5. Cross Flow Fan and Indoor Fan Motor Removal
Procedures 
78
 12.6. Outdoor Electronic Controller Removal Procedure 
80
 13 Technical Data 
81
 14 Exploded View 
84
Room Air Conditioner
CONTENTS
 Page 
Page
Order No. MAC0308013C2
 15 Replacement Parts List 
85
 16 Exploded View 
86
 17 Replacement Parts List 
87
 18 Electronic Circuit Diagram 
88
 18.1. REMOTE CONTROL 
98
  • Product
  − Microcomputer-controlled
compressor
operating
frequency
  − Vertical and Horizontal Airflow Directions
  − Five modes of operation selection
  − Powerful Mode operation
  − Delay ON Timer and OFF Timer
  − Remote Control with illuminable buttons
  − Power Monitor Display LED
  − Catechin Air Purifying Filter
  − Triple Deodorizing Filter
  − Ionizer Mode Operation
  − Quiet Mode Operation
 18.2. PRINT PATTERNINDOOR UNIT PRINTED CIRCUIT
BOARD 
99
 18.3. PRINT PATTERNOUTDOOR UNIT PRINTED CIRCUIT
BOARD VIEW 
100
  • Serviceability
  − Washable Front Panel
  − Breakdown Self Diagnosis function
  • Environmental Protection
  − Non-ozone depletion substances refrigerant (R410A)
  • Quality Improvement
  − Gas leakage detection
  − Deice operation
  − Auto restart control
1 Features
2
2 Functions
Remote Control
Operation OFF / ON
OFF/ON
I
Room Temperature Setting
TEMP
Operation Mode Selection
a
Automatic Operation
HEAT
Heating Operation
COOL
Cooling Operation
DRY
Soft Dry Operation
FAN
Fan Operation
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Quiet Mode Operation
QUIET
Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
Timer Setting
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
CLOCK
Powerful Mode Operation
POWERFUL
• Increase or decrease set temperature.
(16°C to 30°C)
Vertical Automatic Airflow
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Horizontal Automatic Airflow
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Indoor Fan Speed Selection
FAN SPEED
Low
Medium-
Medium
Medium+
High
AUTO
Automatic Fan Speed
FAN
Check Point
Reset Point
RESET
SET
CANCEL
CHECK
MODE
AIR SWING
• Breakdown self diagnosis function.
• Clear memory data.
Ion Mode Operation
Illuminable
buttons
TIMER
OFF
ON
3
Indoor Unit
Automatic Operation Switch
• Press for < 5s to run Automatic Operation.
(Used when the remote control cannot be used.)
• Press continuously for 5s and < 8s to run
Forced Cooling Operation.
• Press continuously for 8s and < 11s to
run Forced Heating Operation.
• Press continuously for 11s and < 16s to
change different remote controlling
setting (4 type of transmission code).
• Press continuously for 16s or < 21s  to
switch OFF / ON Remote Control
Receiving Sound or H14 Abnormality
Detection Mode.
Operation Indication Lamps (LED)
Quiet Mode
Five Operation Modes
• Automatic, Heating, Cooling, Soft Dry
and Fan Operation.
Delay ON Timer and OFF Timer
Powerful Mode
• For quick cooling or heating.
POWER
(Green) ...... Lights up during
MONITOR
compressor operation.
 (Green) ............ Lights up in Ionizer
Mode Operation.
Blinks in Ionizer
error.
POWER
(Green) ...... Lights up in operation,
blinks in Automatic
Operation Mode
judging, deice, On
Timer sampling and
Hot Start operation.
POWERFUL
 (Orange) ... Lights up when
Powerful Mode is
selected.
QUIET
(Orange) .... Lights up in Quiet
Mode Operation.
TIMER
(Orange) .... Lights up in Timer
Setting.
Blinks in Self
Diagnosis Control.
Automatic and 5 Manual Indoor
Fan Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Automatic Restart Control
• Operation is restarted after power failure
at previous setting mode.
Microcomputer-controlled Room
Temperature Control
• To provide extra quiet operation.
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
4
Page of 100
Display

Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Service Manual ▷ Download

  • DOWNLOAD Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Service Manual ↓ Size: 13.85 MB | Pages: 100 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Air Conditioner. Information contained in Panasonic CS-E18CKE / CU-E18CKE / CS-E21CKE / CU-E21CKE Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.