8.1.3. Indoor Fan Motor Operation
There are 31 fan speed numbers assigned for different fan speed operation at designed conditions, as shown in below table. The
fan speed can be set manually using remote control (5 speeds for cooling mode: Lo, Me-, Me, Me+, Hi; 5 speeds for heating: Lo,
Me-, Me, Me+, Shi) or let it automatically changes depending on the operation and its environment.
Fan
Speed
No.
CS-E9CKP
CS-E12CKP
Remark
Voltage
(V)
Cooling
Dry
Heating
Voltage
(v)
Cooling
Dry
Heating
0
OFF
OFF
OFF
OFF
OFF
OFF
- Hot start control.
- Deice control.
1
2
3.03
3.03
3
3.05
SLo
3.05
SLo
- Soft Dry operation mode.
- ON timer pre-operation (D).
4
3.13
3.13
- Auto operation mode judgment (C/D).
- ON timer preparation sampling (C/D).
5
3.15
3.23
- Auto operation mode judgment (H).
- ON timer preparation sampling (H).
6
3.16
Lo
3.29
Lo
- ON timer pre-operation at Auto fan (C).
7
3.23
Lo
3.34
- ON timer pre-operation at Auto fan for E9CKP
(H).
8
3.24
3.40
9
3.31
Me-
3.44
Me-
10
3.36
3.53
11
3.39
Me-
3.60
Me
- Powerful Mode at Lo fan for E12CKP (C).
12
3.44
3.63
13
3.47
Me
3.66
Lo
- Powerful Mode at Lo fan for E9CKP (C).
- ON timer pre-operation at Auto fan for E12CKP
(H).
14
3.55
Me
3.68
- Powerful Mode at Lo fan for E9CKP (H).
15
3.57
3.71
16
3.60
3.75
Me-
17
3.63
Me+
3.77
Me+
- Powerful Mode at Me- fan (C).
18
3.66
3.83
19
3.68
3.85
20
3.71
3.86
Me
- Powerful Mode at Lo fan for E12CKP (H).
21
3.73
Me+
3.91
- Powerful Mode at Me- fan for E9CKP (H).
22
3.77
3.94
23
3.79
3.98
Me+
- Powerful Mode at Me- fan for E12CKP (H).
24
3.80
4.00
25
3.82
Hi
4.00
Hi
- Powerful mode at Me, Me+ or Hi fan (C).
26
3.85
4.01
27
3.89
4.05
SHi
28
3.90
SHi
4.08
29
3.91
4.11
30
3.93
SHi
4.16
SHi
- Powerful mode at Me, Me+ or Hi fan (H).
31
4.07
4.30
21
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
8.1.4. Cooling Mode Automatic Indoor Fan Speed
The automatic fan speed for cooling operation is as shown in below patterns (a
→ b → c → → h) with each pattern 10 seconds.
The fan speed for each level (X or Y or Z) is as below table.
Model No.
E9CKP
E12CKP
Level
X
Y
Z
X
Y
Z
Normal Operation Fan Speed No.
11
9
7
10
9
7
Powerful Mode Fan Speed No.
13
11
9
12
10
9
(a) During cooling operation, if all the following conditions occur, indoor fan speed will be shifted to Shi internally.
(i) Indoor intake air temperature
24°C.
(ii) Instructed frequency = 39 Hz (E9CKP) or 52 Hz (E12CKP).
(iii) Remote controller setting temperature = 16°C.
(iv) Remote controller setting fan speed = Hi.
(v) Outdoor air temperature
30°C.
(vi) Operation starts
30 minutes.
8.1.5. Heating Mode Indoor Fan Motor Operation (Anti Cold draft Control)
Indoor fan speed varies in accordance to indoor heat exchanger temperature, based on type of air volume and direction, as shown
below.
 1. Manual Fan Speed
22
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
 2. Auto Fan Speed
Note:
 a. UP:
  • If move from Lo or Lo-, the fan speed will be shifted to Maximum.
  • If move from Maximum, the fan speed no change.
  • Other than that, the fan speed will be increased one Fan Speed No.
 b. DOWN:
  •  The fan speed will be decreased one Fan Speed No.
 c. 
Fix:
  • No change in fan speed.
 d. Maximum:
  • Fan speed will be increased to maximum auto fan speed.
 e. Temperature in ( ) is for Powerful Mode operation.
8.1.6. Outdoor Fan Motor Operation
Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation.
23
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
8.1.7. Airflow Direction
 1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes).
 2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature
and intake air temperature) and manual (angles of direction can be adjusted using remote controller).
Vertical Airflow
Operation Mode
Airflow Direction
Vane Angle (°)
1
2
3
4
5
Heating
Auto, with Heat Exchanger
A
17
Temperature
B
58
C
7
Manual
7
17
33
49
67
Cooling, Soft Dry and Fan, Ion
Auto
7 ~ 37
Manual
7
17
25
33
41
Mode Judgment in Auto
Auto
7
Manual
7
17
25
33
41
 1. Automatic vertical airflow direction can be set using remote controller; the vane swings up and down within the angles as
stated above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as
Figure 1 below. When the air conditioner is stopped using remote controller, the vane will shift to close position.
 2. Manual vertical airflow direction can be set using remote controller; the angles of the vane are as stated above and the
positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote controller, the vane will shift
to close position.
Horizontal Airflow
 1. Automatic horizontal airflow direction can be set using remote controller; the vane swings left and right within the angles as
stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as
Figure 1 below.
Operation Mode
Vane Angle (°)
Heating, with heat exchanger temperature
A
55 ~ 125
B
90
Cooling, Soft Dry and Fan, Ion
55 ~ 125
24
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
Page of 94
Display