Panasonic CS-E9CKP / CU-E9CKP5 / CS-E12CKP / CU-E12CKP5 Service Manual ▷ View online
1
Features
2
2
Functions
3
3
Product Specifications
6
4
Dimensions
10
5
Refrigeration Cycle Diagram
12
6
Block Diagram
13
7
Wiring Diagram
14
8
Operation Details
16
9
Operating Instructions
41
CS-E9CKP CU-E9CKP5
CS-E12CKP CU-E12CKP5
CS-E12CKP CU-E12CKP5
10 Installation And Servicing Air Conditioner Using R410A
46
11 Installation Instructions
57
12 Servicing Information
66
13 Technical Data
75
14 Exploded View
78
15 Replacement Parts List
79
16 Exploded View
80
17 Replacement Parts List
81
18 Electronic Circuit Diagram
82
Room Air Conditioner
CONTENTS
Page
Page
Order No: MAC0210055C8
• Product
− Microcomputer-controlled
compressor
operating
frequency
− Vertical and Horizontal Airflow Directions
− Five modes of operation selection
− Power Mode operation
− Delay ON Timer and OFF Timer
− Standby operation
− Remote Controller with illuminable buttons
− Power Monitor Display LED
− Catechin Air Purifying Filter
− Triple Deodorizing Filter
− Ionizer Mode Operation
− Quiet Mode Operation
− Five modes of operation selection
− Power Mode operation
− Delay ON Timer and OFF Timer
− Standby operation
− Remote Controller with illuminable buttons
− Power Monitor Display LED
− Catechin Air Purifying Filter
− Triple Deodorizing Filter
− Ionizer Mode Operation
− Quiet Mode Operation
• Serviceability
− Washable Front Panel
− Breakdown Self Diagnosis function
− Breakdown Self Diagnosis function
• Environmental Protection
− Non-ozone depletion substances refrigerant (R410A)
• Quality Improvement
− Gas leakage detection
− Deice operation
− Auto restart control
− Deice operation
− Auto restart control
1 Features
2
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
2 Functions
Remote Control
Operation OFF / ON
OFF/ON
I
Room Temperature Setting
TEMP
Operation Mode Selection
•
a
Automatic Operation
•
HEAT
Heating Operation
•
COOL
Cooling Operation
•
DRY
Soft Dry Operation
•
FAN
Fan Operation
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Quiet Mode Operation OFF / ON
QUIET
Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
Timer Operation Selection
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
CLOCK
Powerful Mode Operation
POWERFUL
• Temperature Setting (16°C to 30°C)
Illuminable
buttons
•
Vertical Automatic Airflow
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
•
Horizontal Automatic Airflow
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Indoor Fan Speed Selection
FAN SPEED
•
Low
•
Medium-
•
Medium
•
Medium+
•
High
•
AUTO
Automatic Fan Speed
FAN
Check Point
Reset Point
RESET
ON
TIMER
OFF
∧
∨
SET
CANCEL
CHECK
MODE
AIR SWING
• Breakdown self diagnosis function.
• Clear memory data.
Ion Mode Operation OFF / ON
3
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
Indoor Unit
Automatic Operation Switch
• Press for < 5s to run Automatic Operation.
(Used when the remote control cannot be used.)
• Press continuously for 5s and < 8s to run
Forced Cooling Operation.
• Press continuously for 8s and < 11s to
run Forced Heating Operation.
• Press continuously for 11s and < 16s to
change different remote controlling
setting (A
setting (A
↔B Mode).
• Press continuously for 16s or < 21s to
switch OFF / ON Remote Control
Receiving Sound or H14 Abnormality
Detection Mode.
Receiving Sound or H14 Abnormality
Detection Mode.
Operation Indication Lamps (LED)
Quiet Mode
Five Operation Modes
• Automatic, Heating, Cooling, Soft Dry
and Fan Operation.
Delay ON Timer and OFF Timer
Powerful Mode
• For quick cooling or heating.
•
POWER
(Green) ...... Lights up during
MONITOR
compressor operation.
•
(Green) ............ Lights up in Ionizer
Mode Operation.
•
POWER
(Green) ...... Lights up in
operation, blinks in
Automatic Operation
Mode judging and Hot
Start operation.
Automatic Operation
Mode judging and Hot
Start operation.
•
TIMER
(Orange) .... Lights up in Timer
Setting.
Blinks in Self
Diagnosis Control.
Blinks in Self
Diagnosis Control.
•
QUIET
(Orange) .... Lights up in Quiet
Mode Operation.
•
POWERFUL
(Orange) ... Lights up when
Powerful Mode is
selected.
selected.
Automatic and 5 Manual Indoor
Fan Speeds
Fan Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Airflow Directions
Automatic Restart Control
• Operation is restarted after power failure
at previous setting mode.
Microcomputer-controlled Room
Temperature Control
Temperature Control
• To provide extra quiet operation.
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
4
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5