89 
16.4.15  H36 (Outdoor Gas Pipe Sensor Abnormality) 
Malfunction Decision Conditions 
š  During startup and operation of cooling and heating, the temperatures detected by the outdoor gas pipe 
temperature sensor are used to determine sensor errors. 
 
Malfunction Caused 
š Faulty 
connector 
connection. 
š Faulty 
sensor. 
š Faulty 
PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
90 
16.4.16  H37 (Outdoor Liquid Pipe Temperature Sensor Abnormality) 
Malfunction Decision Conditions 
š  During startup and operation of cooling and heating, the temperatures detected by the outdoor liquid pipe 
temperature sensor are used to determine sensor errors. 
 
Malfunction Caused 
š Faulty 
connector 
connection. 
š Faulty 
sensor. 
š Faulty 
PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
91 
16.4.17  H97 (Outdoor Fan Motor – DC Motor Mechanism Locked) 
Malfunction Decision Conditions 
š  The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor. 
 
Malfunction Caused 
š  Operation stops due to short circuit inside the fan motor winding. 
š  Operation stops due to breaking of wire inside the fan motor. 
š  Operation stops due to breaking of fan motor lead wires. 
š  Operation stops due to Hall IC malfunction. 
š  Operation error due to faulty outdoor unit PCB. 
 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
92 
16.4.18  H98 (Indoor High Pressure Protection) 
Error Code will not display (no Timer LED blinking) but store in EEPROM 
 
Malfunction Decision Conditions 
š  During heating operation, the temperature detected by the indoor pipe temperature sensor is above 60°C. 
 
Malfunction Caused 
š  Air short circuit at indoor unit 
š  Clogged indoor unit air filter 
š  Dust accumulation on the indoor unit heat exchanger 
š  2/3 way valve closed 
š  Faulty indoor unit fan motor 
š Excessive 
refrigerant 
š  Clogged expansion valve or strainer 
š  Faulty indoor pipe temperature sensor 
š  Faulty indoor unit PCB 
 
Troubleshooting 
 
 
 