16.4.27    F97 (Compressor Overheating) 
Malfunction Decision Conditions 
š  During operation of cooling and heating, when compressor tank temperature data (112°C) is detected by the 
compressor tank temperature sensor. 
 
Malfunction Caused 
š  Faulty compressor tank temperature sensor 
š  2/3 way valve closed 
š  Refrigerant shortage (refrigerant leakage) 
š  Faulty outdoor unit PCB 
š Faulty 
compressor 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
102 
16.4.28    F98 (Input Over Current Detection) 
Malfunction Decision Conditions 
š  During operation of cooling and heating, when an input over-current (X value in Total Running Current Control) is 
detected by checking the input current value being detected by current transformer (CT) with the compressor 
running. 
 
Malfunction Caused 
š Excessive 
refrigerant. 
š  Faulty outdoor unit PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
103 
16.4.29    F99 (Output Over Current Detection) 
Malfunction Decision Conditions 
š  During operation of cooling and heating, when an output over-current (DC peak current value at IPM Prevention 
Control) is detected by checking the current that flows in the inverter DC peak sensing circuitry. 
 
Malfunction Caused 
š  Faulty outdoor unit PCB 
š Faulty 
compressor 
 
Troubleshooting 
 
 
 
š  Checking the power transistor 
š  Never touch any live parts for at least 10 minutes after turning off the circuit breaker. 
š  If unavoidable necessary to touch a live part, make sure the power transistor’s supply voltage is below 50V using 
the tester. 
š  For the UVW, make measurement at the Faston terminal on the board of the relay connector. 
 
Tester’s negative terminal 
Power transistor (+) 
UVW 
Power transistor (-) 
UVW 
Tester’s positive terminal 
UVW 
Power transistor (+) 
UVW 
Power transistor (-) 
Normal resistance 
Several kΩ to several MΩ 
Abnormal resistance 
0 or ∞ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
104 
WARNING 
17.  Disassembly and Assembly Instructions 
 
 
 
High voltages are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding 
with repair work. Failure to heed this caution may result in electric shocks. 
17.1  CS-E7NK  CS-E9NK  CS-E12NK  CS-E15NK 
17.1.1  Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal 
Procedures 
17.1.1.1  To remove front grille 
 
 
Figure 1 
 
17.1.1.2  To remove electronic controller 
 
 
Figure 2 
Page of 127
Display

Click on the first or last page to see other CS-E7NKDW / CS-E9NKDW / CS-E12NKDW / CS-E15NKDW / CS-E18NKDW / CU-E7NKD / CU-E9NKD / CU-E12NKD / CU-E15NKD / CU-E18NKD service manuals if exist.