DOWNLOAD Panasonic CS-E7NKDW / CS-E9NKDW / CS-E12NKDW / CS-E15NKDW / CS-E18NKDW / CU-E7NKD / CU-E9NKD / CU-E12NKD / CU-E15NKD / CU-E18NKD Service Manual ↓ Size: 24.08 MB | Pages: 127 in PDF or view online for FREE

Model
CS-E7NKDW CS-E9NKDW CS-E12NKDW CS-E15NKDW CS-E18NKDW CU-E7NKD CU-E9NKD CU-E12NKD CU-E15NKD CU-E18NKD
Pages
127
Size
24.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e7nkdw-cs-e9nkdw-cs-e12nkdw-cs-e15nkdw-cs-e18nk.pdf
Date

Panasonic CS-E7NKDW / CS-E9NKDW / CS-E12NKDW / CS-E15NKDW / CS-E18NKDW / CU-E7NKD / CU-E9NKD / CU-E12NKD / CU-E15NKD / CU-E18NKD Service Manual ▷ View online

93 
16.4.19    H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) 
Error Code will not display (no Timer LED blinking) but store in EEPROM 
 
Malfunction Decision Conditions 
š  Freeze prevention control takes place (when indoor pipe temperature is lower than 2°C) 
 
Malfunction Caused 
š  Air short circuit at indoor unit 
š  Clogged indoor unit air filter 
š  Dust accumulation on the indoor unit heat exchanger 
š  2/3 way valve closed 
š  Faulty indoor unit fan motor 
š  Refrigerant shortage (refrigerant leakage) 
š  Clogged expansion valve or strainer 
š  Faulty indoor pipe temperature sensor 
š  Faulty indoor unit PCB 
 
Troubleshooting 
 
 
 
 
 
 
 
94 
16.4.20    F11 (4-way valve Abnormality) 
Malfunction Decision Conditions 
š  When heating operation, when indoor pipe temperature is below 10°C 
š  When cooling operation, when indoor pipe temperature is above 45°C 
 
Malfunction Caused 
š  Connector in poor contact 
š Faulty 
sensor 
š  Faulty outdoor unit PCB 
š  4-way valve defective 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
95 
16.4.21  F17 (Indoor Standby Units Freezing Abnormality) 
Malfunction Decision Conditions 
š  When the different between indoor intake air temperature and indoor pipe temperature is above 10°C or indoor 
pipe temperature is below -1.0°C 
 
Remark: 
When the indoor standby unit is freezing, the outdoor unit transfers F17 error code to the corresponding indoor 
unit and H39 to other indoor unit(s). 
 
Malfunction Caused 
š  Wrong wiring connection 
š Faulty 
sensor 
š  Faulty expansion valve 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
96 
16.4.22    F90 (Power Factor Correction Protection) 
Malfunction Decision Conditions 
š  During startup and operation of cooling and heating, when Power Factor Correction (PFC) protection circuitry at 
the outdoor unit main PCB senses abnormal high DC voltage level. 
 
Malfunction Caused 
š  DC voltage peak due to power supply surge. 
š  DC voltage peak due to compressor windings not uniform. 
š  Faulty outdoor PCB. 
 
Troubleshooting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127