11. Installation 
Information 
11.1 Check Points 
 
11.2  The Shapes of the 3-Way Valve Caps of the Outdoor Unit Have Changed. 
 
•  Accompanying the changes in the shapes of the 3-way valve caps, the tightening method has also been 
changed. 
•  Firmly tighten the 3-way valve caps by hand and then tighten them up by another 30 degrees or so (one-twelfth 
of a full turn) using a spanner or adjustable spanner. 
 
 
 
Panasoni c
Panasoni c
Allowable
elevation:
10m max
.
The allowable
elevation between
each of the indoor
units and between
the indoor and
outdoor units.
1.5mm
2
 flexible cord x 4 core
(poluchloroprene sheathed)
(Not included in the unit)
Outdoor unit power supply:
Single-phase 230V, 50Hz
20A switch
(circuit breaker)
(Not included in the unit)
1.5 mm2 or more x 3 core
(Not included in the unit)
Drain work
Drain elbow
(Inner diameter: 16mm) provided
Outdoor wiring work
Unit B
Unit A
Applicable connecting tube kit:
CZ-3F type
Total maximum pipe length: 30 m
Air purging: Air purging by vacuum pump.
Unit A   Maximum pipe length: 20 m
Unit B   Maximum pipe length: 20 m
Indoor/outdoor unit 
connection cables
(Not included in the unit)
Grounding work
Caution:
Do not use all your strength to tighten up
the caps. Doing so may break the caps.
After having firmly tightened the caps by hand,
tighten them up further using a
spanner or adjustable spanner.
 
26 
11.3 Piping Length 
Piping size 
Gas Liquid 
Common Length 
(m) 
Min. Total Length 
(m) 
Max. Total Length 
(m) 
Max. Elevation (m) 
Additional gas 
charge amount 
(g/m) 
3/8” 
1/4" 
20 
6 (3m / indoor unit)
30 x 1 
10 
20 x 2 
Note: 
1. 
It is possible to extend the piping length of one unit up to 20 meters. However, the total piping length must not exceed 30 meters. 
2. 
If the piping length exceeds 20 meters, refrigerant of 20g per meter must be added. 
 
 
Panasonic
Panasonic
Panasonic
Panasonic
Panasonic
Panasonic
Panasonic
Panasonic
• Maximum Piping Length
• Maximum Piping Length
• Maximum Piping Length
• Maximum Piping Length
• Additional Gas Charge
  (30m - 20m) x 20g = 200g
• Additional Gas Charge
  (30m - 20m) x 20g = 200g
• Additional Gas Charge
  (30m - 20m) x 20g = 200g
Indoor Unit A
Indoor Unit A
Indoor Unit A
Indoor Unit A
Indoor Unit B
Indoor Unit B
Indoor Unit B
Indoor Unit B
Outdoor
Unit
Outdoor
Unit
Outdoor
Unit
Outdoor
Unit
10m
10m
3m
3m
10m
15m
15m
15m
15m
10m
10m
20m
27 
10
 cm
or 
mo
re
10 cm
or more
100
 cm
or m
ore
30 cm
or m
ore
cm
 o
r
m
or
e
5 cm
or more
Piping direction
Right
Right
  Rear
Right bottom Left
Rear
Left bottom
Left
(Front side)
Attention not to bend
up drain hose
Insulation of piping connections
• Carry out insulation after
   checking for gas leaks and
   secure with vinyl tape.
Attaching the remote control holder to
the wall
Remote control holder
fixing screws 6
Remote
control 3
Remote
control
holder 5
•  This illustration is for explanation purposes only.
   The indoor unit will actually face a different way.
(*) Vinly tape
AUTO
HEAT
COOL
DRY
FAN
SPEED
AIR
SWING
e
-Ion
PA TROL
OFF/ON
TEMP
MODE
FAN SPEED
AIR
SWING
QUIET
TIMER
POWERFUL
ON
SET
OFF
CANCEL
1
2
3
AC
SET CHECKCLOCK RESET
RC
Panasoni
c
INVERTER
(Left and right
are identical)
Installation plate 1
Sleeve (*)
Bushing-Sleeve (*)
Putty (Gum Type Sealer) (*)
Bend the pipe as closely on the wall as possible,
but be careful that it doesn’t break
Vinyl tape (Wide) (*)
• Apply after carrying out a drainage test.
• To carry out the drainage test, remove the air
  filters and pour water into the heat exchanger.
Saddle (*)
Connecting cable
4 x 1.5 mm
2
or more.
Type designation 245 IEC 57 (H05RN-F)
Additional drain hose (*)
1/4” Liquid side piping (*)
3/8” Gas side piping (*)
Installation parts you
should purchase (*)
15A
Breaker
50Hz
230V
Power supply cable:
3 x 1.5mm
2
 or more.
Type designation 245 ICE
57 (H05RN-F)
12. Installation 
Instruction 
12.1  Select the Best Location 
12.1.1 Indoor 
Unit 
•  There should not be any heat source or steam near the unit. 
•  There should not be any obstacles blocking the air circulation. 
•  A place where air circulation in the room is good. 
•  A place where drainage can be easily done. 
•  A place where noise prevention is taken into consideration. 
•  Do not install the unit near the door way. 
•  Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. 
•  Recommended installation height for indoor unit shall be at least 2.3m. 
 
12.1.2 Outdoor 
Unit 
•  If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the 
condenser is not obstructed. 
•  There should not be any animal or plant which could be affected by hot air discharged. 
•  Keep the spaces indicated by arrows from wall, ceiling, fence or other obstrucles. 
•  Do not place any obstrucles which may cause a short circuit of the discharged air. 
•  If piping length is over the rated length, additional refrigerant should be added as shown in the table below: 
 
Piping size 
Model 
Gas Liquid 
Rated Length (m) Max Elevation (m) Min Piping Length 
(m) 
Max Total Piping 
Length (m) 
Additional 
Refrigerant (g/m) 
CU-2E15GBE 
3/8” 
1/4” 
15 
10 
3m / Indoor Unit 
30 
20 
Note: 
1.  It is possible to extend the piping length of one unit to 20 meters. However, the total piping length must not 
exceed 30 meters. 
2.  If the piping length exceeds 20 meters, refrigerant of 20g per meter must be added. 
12.1.3  Indoor/Outdoor Unit Installation Diagram 
 
 
28 
Bushing for tube
ass'y
15 mm
Outdoor
Indoor
Wall
Sleeve for
tube ass'y
ø70 through hole
Putty or caulking compound
Approx. 5 - 7 mm
12.2 Indoor Unit 
12.2.1  How to Fix Installation Plate 
The mounting wall is strong and solid enough to prevent if from the vibration. 
 
The centre of installation plate should be at 
more than 450 mm at right and left of the wall. 
 
The distance from installation plate edge to 
ceiling should more than 67mm. 
 
From installation plate left edge to unit’s left side 
is 74mm. 
 
From installation plate right edge to unit’s right 
side is 94mm. 
 
 
: For left side piping, piping connection for liquid should be about 15mm from this line. 
B  
: For left side piping, piping connection for gas should be about 45mm from this line. 
 
: For left side piping, piping connection cable should be about 800mm from this line. 
 
1.  Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider 
using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with the 
thread and using a level gauge. 
2.  Drill the piping plate hole with ø70mm hole-core drill. 
o
 
Line according to the left and right side edge of the installation plate. The meeting point of the extended 
line is the centre of the hole. Another method is by putting measuring tape at position as shown in the 
diagram above. The hole centre is obtained by measuring the distance namely 150mm and 125mm for 
left and right hole respectively. 
o
 
Drill the piping plate hole at either the right or left and the hole should be slightly slanted to the outdoor 
side. 
 
12.2.2  To Drill a Hole in the Wall and Install a Sleeve of Piping 
1.  Insert the piping sleeve to the hole. 
2.  Fix the busing to the sleeve. 
3.  Cut the sleeve until it extrudes about 15mm from the wall  
 
 
 
4.  Finish by sealing the sleeve with putty or caulking compound at the 
final stage.  
 
Caution 
When the wall is hollow, please be sure to use the sleeve for tube 
ass’y to prevent dangers caused by mice biting the connecting 
cable. 