12.2.3  Indoor Unit Installation 
12.2.3.1 
For the right rear piping 
 
 
12.2.3.2 
For the right and right bottom piping 
 
 
 
Pull out the Indoor Piping 
Install the Indoor Unit 
Secure the Indoor Unit 
Insert the connecting cable 
Pull out the Indoor Piping 
Install the Indoor Unit 
Insert the connecting cable 
Secure the indoor unit 
 
30 
12.2.3.3 
For the embedded piping 
  
 
(This can be used for left rear piping & left bottom piping also.) 
 
 
Replace the drain hose 
Bend the embedded piping 
Install the Indoor Unit 
Cut and flare the 
embedded piping 
Pull the connecting cable 
into indoor unit 
Connect the piping 
Insulate and finish the 
piping 
Secure the Indoor Unit 
• 
Use a spring bender or equivalent to bend the 
piping so that the piping is not crushed. 
• 
When determining the dimensions of the piping, 
slide the unit all the way to the left on the 
installation plate. 
• 
Refer to the section “Cutting and flaring the 
piping”. 
• 
The inside and outside connecting cable can be 
connected without removing the front grille. 
• 
Please refer to “Connecting the piping” column in 
the outdoor unit section (Below steps are done 
after connecting the outdoor piping and gas-
leakage confirmation 
• 
Please refer to “Piping and finishing” column in the 
outdoor section and “Insulation of piping 
connections” column as mentioned in 
Indoor/Outdoor unit installation. 
31 
12.2.4  Connect the Cable to the Indoor Unit 
1.  The inside and outside connecting cable can be connected without removing the front grille. 
2.  Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 
(C9GK, C12GK) x 1.5mm
2
 flexible cord, type designation 245 IEC 57 or heavier cord. 
o
 
Ensure the color of wires of outdoor unit and the terminal numbers are the same to the indoor’s 
respectively. 
o
 
Earth lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety 
in case of the slipping out of the cord from the anchorage. 
 
 
 
 
 
 
o
 
Secure the cable onto the board with the holder (clamper). 
 
 
 
 
 
 
 
 
 
 
12.3 Outdoor Unit 
12.3.1  Install the Outdoor Unit 
•  After selecting the best location, start installation according to indoor/outdoor unit installation diagram. 
1.  Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10mm). 
2.  When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand 
firmly with bolt or nails. 
 
 
 
 
 
 
 
 
 
 
12.3.2  Connecting the Piping 
12.3.2.1 Connecting 
the 
piping to indoor unit 
Please make flare after inserting flare nut (locate at joint portion, of tube assembly) onto the copper pipe. (In case of 
using long piping) 
 
Connect the piping 
•  Align the center of piping and sufficiently tighten the flare nut with fingers. 
•  Further tighten the flare nut with torque wrench in specified torque as stated in the table. 
 
 
Piping size (Torque) 
Model 
Gas Liquid 
E7GK, E9GK, E12GK 
3/8” (42 Nm) 
1/4 (18 Nm) 
E15GK, E18GK 
1/2” (55 Nm) 
1/4 (18 Nm) 
Terminals on the indoor unit
1
2
3
Color of wires
Terminals on the outdoor unit
1
2
3
1
2
3
570
5.
81
02
3
105
Spanner
or wrench
Torque
wrench
 
32 
1. To cut
Bar
0 - 0.5 mm
Copper pipe
Handle
Bar
Yoke
Core
Red arrow mark
Clamp handle
3. To flare
Pipe
Reamer
Point down
2. To remove burrs
Improper flaring
Uneven
thickness
Inclined Surface
damaged
Cracked
When properly flared, the internal surface
of the flare will evenly shine and be of
even thickness. Since the flare part
comes into contact with the connections,
carefully check the flare finish.
Lo
OPEN
Vacuum pump adaptor
Vacuum
 pump
GAS SIDE
Liquid side
Indoor unit
GAS SIDE
Liquid side
Indoor unit
Hi
CLOSE
THREE-WAY VALVE
THREE-WAY VALVE
THREE-WAY VALVE
THREE-WAY VALVE
Outdoor unit
12.3.2.2 
Connecting the piping to outdoor unit 
Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the 
flare nut (locate at valve) onto the copper pipe. Align center of piping to valves and then tighten with torque wrench 
to the specified torque as stated in the table. 
 
12.3.2.3 
Cutting and flaring the piping 
1.  Please cut using pipe cutter and then remove the burrs. 
2.  Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping 
end down to avoid the metal powder entering the pipe. 
3.  Please make flare after inserting the flare nut onto the copper pipes. 
 
 
12.3.3  Evacuation of the Equipment 
WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT 
AND PIPES in the following procedure.  
 
1.  Connect a charging hose with a push pin to 
the Low side of a charging set and the 
service port of the 3-way valve. 
o
 
Be sure to connect the end of the 
charging hose with the push pin to the 
service port. 
2.  Connect the center hose of the charging 
hose of the charging set to a vacuum pump. 
3.  Turn on the power witch of the vacuum pump 
and make sure that the needle in the gauge 
moves from 0cmHg (0MPa) to -76cmHg (-
0.1MPa). Then evacuate the air 
approximately ten minutes. 
4.  Close the Low side valve of the charging set 
and turn off the vacuum pump. Make sure 
that the needle in the gauge does not move 
after approximately five minutes. 
Note: BE SURE TO FOLLOW THIS 
PROCEDURE IN ORDER TO AVOID 
REFRIGERANT GAS LEAKAGE. 
5.  Disconnect the charging hose from the 
vacuum pump and from the service port of 
the 3-way valve. 
6.  Tighten the service port caps of the 3-way 
valve at torque of 18N.m. with a torque 
wrench. 
7.  Remove the valve caps of both of the 2-way 
valve and 3-way valve. Position both of the 
valves to “OPEN” using a hexagonal wrench 
(4mm). 
8.  Mount valve caps onto the 2-way valve and 
the 3-way valve. 
o
 
Be sure to check for gas leakage. 