CAUTION 
•  If gauge needle does not move from 0cmHg (0MPa) to -76cmHg (-0.1MPa), in step 3 above take the following 
measure: 
•  If the leak stops when the piping connections are tightened further, continue working from step 3. 
•  If the leak does not stop when the connections are retightened, repair the location of leak. 
•  Do not release refrigerant during piping work for installation and reinstallation. Take care of the liquid 
refrigerant, it may cause frostbite. 
 
12.3.4  Connect the cable to the Outdoor Unit 
1.  Remove the control board cover from the unit by loosening the screw. 
2.  Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 
(C9GK, C12GK) x 1.5mm2 flexible cord, type designation 245 IEC 57 or heavier cord. 
 
 
 
 
 
 
 
3.  Secure the cable onto the control board with the holder (clamper). 
4.  Attach the control board cover back to the original position with the screw. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12.3.5 Pipe 
Insulation 
1.  Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation 
Diagram. Please warp the insulated piping end to prevent water from going inside the piping. 
2.  If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by 
using POLY-E-FOAM with thickness 6mm or above. 
 
Terminals on the indoor unit
1
2
3
Color of wires
Terminals on the outdoor unit
1
2
3
Control board
Control board cover
Power
supply
cord
Indoor
unit A
Indoor
unit B
15A
Breaker
Control board
Power supply cord
 
34 
13. Operation 
Control 
13.1  Simultaneous Operation Control 
•  Operation modes which can be selected using the remote control unit: 
o
  Automatic, Cooling, Dry, Heating and e-ion operation mode. 
•  Types of operation modes which can be performed simultaneously 
o
  Cooling operation and Cooling, Dry or e-ion operation 
o
  Heating operation and Heating operation 
•  Types of operation modes which cannot be performed simultaneously 
o
  During cooling operation, heating operation is impossible at another indoor unit in another room. 
o
  The priority is given to cooling operation if the cooling mode is selected first. In another room where heating 
mode is selected afterward, the POWER LED blinks to indicate the heating operation is in standby condition, 
where the fan is stopped hence no discharged air. 
o
  During heating operation, cooling operation is impossible at another indoor unit in another room. 
o
  The priority is given to heating operation if the heating mode is selected first. In another room where cooling 
mode is selected afterward, the POWER LED blinks to indicate the cooling operation is in standby condition, 
where the fan is stopped hence no discharged air. 
•  Operation mode priority control 
o
  The operation mode designated first by the indoor unit has priority. 
o
  If the priority indoor unit stops operation or initiates the fan operation, the priority is transferred to other 
indoor units. 
 
“Waiting” denotes the standby status in which the POWER LED blinks (ON for 2.5 seconds and OFF for 0.5 seconds) 
and the fan is stopped. 
Non Priority Unit (2
nd
 ON) 
ROOM A 
 
   ROOM B 
Cooling Dry Heating e-ion 
Cooling 
 
 
Waiting 
 
 
Dry 
 
 
Waiting 
 
 
Heating 
Waiting 
 
Waiting 
 
 
Stop 
 
Pr
ior
ity Unit (
1
st
 ON) 
e-ion 
 
 
 
Stop 
 
In the e-ion mode, priority is transferred to a non-priority unit. 
Note 
•  C: Cooling operation mode 
•  D: Dry operation mode 
•  H: Heating operation mode 
•  F: e-ion operation mode 
 
35 
Compressor 
 OFF 
2.5°C
-1.5°
Compressor ON 
0.5° 
Intake air temperature 
– Internal setting temp.
13.2 Basic function 
Inverter control, which with a microcomputer in determining the most suitable operating mode as time passes, 
automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating model, 
the microcomputer maintains the set temperature by measuring temperature of the environment and performing 
temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the 
microcomputer at indoor unit that judging the condition according to internal setting and intake air temperature. 
 
13.2.1 Internal 
setting 
temperature 
Once the operation starts, remote control temperature will be taken as base vale for temperature shifting processes. 
These shifting processes are depending on the air conditioner settings and the operation environment. The final 
shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical 
power is supplied to the unit. 
Remote control setting temperature 16°C ~30°C 
↓ 
Auto operation mode shifting 
 ↓ 
Indoor air temperature shifting 
 ↓ 
Outdoor air temperature shifting 
 ↓ 
Powerful mode shifting 
 ↓ 
Setting temperature limit checking  
(Min: 16°C; Max: 33°C) 
 ↓ 
Internal setting temperature 
13.2.2 Cooling 
operation 
13.2.2.1 Thermostat 
control 
•  Compressor is OFF when intake air temperature – Internal setting temperature <-1.5°C. 
•  Compressor is ON after waiting for 3 minutes, if the intake air temperature – Internal setting temperature > 
compressor OFF point. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
36 
-2.5°C
-1.5° 
Compressor ON 
2.0° 
Compressor 
 OFF 
Intake air temperature 
– Internal setting temp.
13.2.3  Soft dry operation 
13.2.3.1 Thermostat 
control 
•  Compressor is OFF when intake air temperature – Internal setting temperature <-1.5°C. 
•  Compressor is ON after waiting for 3 minutes, if the intake air temperature – Internal setting temperature > 
compressor OFF point. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
13.2.4 Heating 
operation 
13.2.4.1 Thermostat 
control 
•  Compressor is OFF when intake air temperature – Internal setting temperature >+2.0°C. 
•  Compressor is ON after waiting for 3 minutes, if the intake air temperature – Internal setting temperature < 
compressor OFF point. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Compressor 
 OFF 
2.5°C
-1.5° 
Compressor ON 
0.5° 
Intake air temperature 
– Internal setting temp.
Page of 77