DOWNLOAD Panasonic CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE Service Manual ↓ Size: 5.8 MB | Pages: 84 in PDF or view online for FREE

Model
CS-CE9JKE CU-CE9JKE CS-CE12JKE CU-CE12JKE
Pages
84
Size
5.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-ce9jke-cu-ce9jke-cs-ce12jke-cu-ce12jke.pdf
Date

Panasonic CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE Service Manual ▷ View online

61
15.4.17. F93 (Compressor Rotation Failure)
Malfunction Decision Conditions
A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit.
Malfunction Caused
• Compressor terminal disconnect
• Outdoor PCB malfunction
Troubleshooting
62
15.4.18. F95 (Cooling High Pressure Abnormality)
Malfunction Decision Conditions
During operation of cooling, when outdoor unit heat exchanger high temperature data (61
°C) is detected by the outdoor pipe
temperature sensor.
Malfunction Caused
• Outdoor pipe temperature rise due to short circuit of hot discharge air flow.
• Outdoor pipe temperature rise due to defective of outdoor fan motor.
• Outdoor pipe temperature rise due to defective outdoor pipe temperature sensor.
• Outdoor pipe temperature rise due to defective outdoor unit PCB.
Troubleshooting
63
15.4.19. F96 (IPM Overheating)
Malfunction Decision Conditions
During operating of cooling and heating, when IPM temperature data (100
°C) is detected by the IPM temperature sensor.
Multi Models Only
• Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.
• Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90
°C) is detected by the
heat sink temperature sensor.
Malfunction Caused
• IPM overheats due to short circuit of hot discharge air flow.
• IPM overheats due to defective of outdoor fan motor.
• IPM overheats due to defective of internal circuitry of IPM.
• IPM overheats due to defective IPM temperature sensor.
Multi Models Only
- Compressor OL connector poor contact.
- Compressor OL faulty.
Troubleshooting
64
15.4.20. F97 (Compressor Overheating)
Malfunction Decision Conditions
During operation of cooling and heating, when compressor tank temperature data (112
°C) is detected by the compressor tank
temperature sensor.
Malfunction Caused
• Refrigerant shortage (refrigerant leakage).
• 2/3 way valve closed.
• Detection error due to faulty compressor tank temperature sensor.
Troubleshooting
Page of 84
Display