DOWNLOAD Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ↓ Size: 4.37 MB | Pages: 105 in PDF or view online for FREE

Model
CS-E10JD3EA U-E10HBEA CS-E15JD3EA CU-E15HBEA CS-E18JD3EA CU-E18HBEA
Pages
105
Size
4.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-e10jd3ea-u-e10hbea-cs-e15jd3ea-cu-e15hbea-cs-e1.pdf
Date

Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ▷ View online

Order No. PHAAM0901093C8
Air Conditioner
Indoor Unit        Outdoor Unit
CS-E10JD3EA
CU-E10HBEA
CS-E15JD3EA
CU-E15HBEA
CS-E18JD3EA
CU-E18HBEA
Please file and use this manual together with the service manual for Model No. CU-3E23CBPG
CU-4E27CBPG, Order No. RAC0209005C2 and CU-3E18JBE  CU-4E23JBE, Order No. PHAAM0901088C2.
2
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions -----------------------------------------------3
2 Specifications 
------------------------------------------------------5
2.1. CS-E10JD3EA CU-E10HBEA --------------------------5
2.2. CS-E15JD3EA CU-E15HBEA --------------------------8
2.3. CS-E18JD3EA CU-E18HBEA ------------------------ 11
3 Features ------------------------------------------------------------ 14
4 Location of Controls and Components 
------------------ 15
4.1. Indoor Unit ------------------------------------------------- 15
4.2. Outdoor Unit ----------------------------------------------- 15
4.3. Remote Control ------------------------------------------- 15
5 Dimensions ------------------------------------------------------- 16
5.1. Indoor Unit & Remote Control ------------------------ 16
5.2. Outdoor Unit ----------------------------------------------- 18
6 Refrigeration Cycle Diagram -------------------------------- 20
7 Block Diagram 
--------------------------------------------------- 21
7.1. CS-E15JD3EA  CU-E15HBEA  CS-
E18JD3EA  CU-E18HBEA----------------------------- 21
7.2. CS-E10JD3EA  CU-E10HBEA ----------------------- 22
8 Wiring Connection Diagram --------------------------------- 23
8.1. Indoor Unit ------------------------------------------------- 23
8.2. Outdoor Unit ----------------------------------------------- 24
9 Electronic Circuit Diagram----------------------------------- 26
9.1. Indoor Unit ------------------------------------------------- 26
9.2. Outdoor Unit ----------------------------------------------- 27
10 Printed Circuit Board ------------------------------------------ 29
10.1. Indoor Unit ------------------------------------------------- 29
10.2. Outdoor Unit ----------------------------------------------- 30
11 Installation Instruction ---------------------------------------- 33
11.1. Indoor Unit ------------------------------------------------- 34
11.2. Outdoor Unit ----------------------------------------------- 40
12 Operation and Control----------------------------------------- 45
12.1. Basic Function -------------------------------------------- 45
12.2. Quiet operation (Cooling Mode/Cooling area
of Soft Dry Mode) ---------------------------------------- 47
12.3. Powerful Mode Operation ------------------------------ 48
12.4. Timer Control---------------------------------------------- 49
12.5. Auto Restart Control------------------------------------- 49
12.6. Indication Panel------------------------------------------- 49
13 Protection Control ---------------------------------------------- 50
13.1. Protection Control For All Operations --------------- 50
13.2. Protection Control For Cooling & Soft Dry
Operation--------------------------------------------------- 51
13.3. Protection Control For Heating Operation --------- 53
14 Servicing Mode -------------------------------------------------- 54
14.1.  TEST RUN OPERATION (FOR PUMP
DOWN/SERVICING PURPOSE)--------------------- 54
15 Troubleshooting Guide---------------------------------------- 56
15.1. Refrigeration Cycle System --------------------------- 56
15.2. Relationship Between The Condition Of The
Air Conditioner And Pressure And Electric
Current ------------------------------------------------------ 57
15.3. Breakdown Self Diagnosis Function ---------------- 58
15.4. Error Codes Table---------------------------------------- 59
15.5. Self-diagnosis Method ---------------------------------- 60
16 Disassembly and Assembly Instructions --------------- 83
16.1. Disassembly of Parts------------------------------------ 83
17 Technical Data---------------------------------------------------- 86
17.1. Operation Characteristics ------------------------------ 86
17.2. Sensible Capacity Chart ------------------------------- 98
18 Exploded View and Replacement Parts List----------- 99
18.1. CS-E10JD3EA  CS-E15JD3EA  CS-
E18JD3EA------------------------------------------------- 99
18.2. CU-E10HBEA-------------------------------------------- 101
18.3. CU-E15HBEA  CU-E18HBEA ----------------------- 103
CAUTION 
WARNING 
WARNING 
1. Safety Precautions 
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
•  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the
power plug and main circuit for the model installed. 
•  The caution items stated here must be followed because these important contents are related to safety. The
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction
will cause harm or damage, and the seriousness is classified by the following indications. 
This indication shows the possibility of causing death or serious injury 
This indication shows the possibility of causing injury or damage to properties. 
•  The items to be followed are classified by the symbols: 
Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 
1.   Do not modify the machine, part, material during repairing service. 
2.  If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 
3.   Do not wrench the fasten terminal. Pull it out or insert it straightly. 
4.   Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water leakage, 
electrical shock or fire. 
5.   Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire. 
6.   Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire 
or electrical shock. 
7.   Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done,
  the set will drop and cause injury. 
8.   For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet
  must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
9.   This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it 
  may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 
10. Do not use joint cable for indoor / outdoor connection cable. Use the specified indoor / outdoor connection cable, refer to installation instruction
      CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoor connection. Clamp the cable so that no external force
      will be acted on the terminal. If connecting or fixing is not perfect, it will cause heat up or fire at the connection.
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause 
  heat-up or fire at the connection point of terminal, fire or electrical shock. 
12. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigeration cycle (piping). 
      (Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may  
  climb up to outdoor unit and cross over the handrail and causing accident.
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and  
  telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown. 
15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. 
16. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with
      other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.
17. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break
      and cause refrigerant gas leakage.
18. In case of using existing (R22) pipes during installation of R410 models, must carry out pump down properly to collect back the  
  refrigerant and oil before installation new unit.
  Thickness of copper pipes used with R410A must be more than 0.6mm. Never use copper pipes thinner than 0.6mm. 
 It is desirable that the amount of residual oil is less than 40 mg/10m. 
19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping
      and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.)
This symbol denotes item that is PROHIBITED from doing. 
CAUTION 
20. During pump down operation, stop the compressor before remove the refrigerant piping. (Removal of refrigeration piping while compressor is
      operating and valves are opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.).
21. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant  
  contacts with fire. 
22. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 
23. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
24. Must not use other parts except original parts describe in catalog and manual. 
1.   Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the  
  unit, it may cause fire. 
2.   Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage  
  the furniture. 
3.   Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare  
  may break and cause refrigerant gas leakage. 
4.   Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 
5.   Select an installation location which is easy for maintenance. 
6.   Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use 
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
  Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 
7.   Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
  methods. 
  Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, 
  permanent connection of this room air conditioner to the power supply is prohibited. 
  i.  Power supply connection to the receptacle using a power plug.  
  Use an approved 15/16A (1.0 ~ 1.75HP) or 16A (2.0HP) or 20A (2.5HP) power plug with earth pin for the connection to the socket. 
  ii. Power supply connection to a circuit breaker for the permanent connection. 
  Use an approved 16A (1.0 ~ 2.0HP) or 20A (2.5HP) circuit breaker for the permanent connection. It must be a double pole switch with a  
  minimum 3.0 mm contact gap. 
8.   Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take  
  care of the liquid refrigerant, it may cause frostbite. 
9.  Installation or servicing work: It may need two people to carry out the installation or servicing work. 
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 
11. Do not sit or step on the unit, you may fall down accidentally. 
12. Do not touch the sharp aluminium fin, sharp parts may cause injury. 
Page of 105
Display

Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ▷ Download

  • DOWNLOAD Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual ↓ Size: 4.37 MB | Pages: 105 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA in PDF for free, which will help you to disassemble, recover, fix and repair Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Air Conditioner. Information contained in Panasonic CS-E10JD3EA / U-E10HBEA / CS-E15JD3EA / CU-E15HBEA / CS-E18JD3EA / CU-E18HBEA Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.