DOWNLOAD Panasonic CS-C7GKD / CU-C7GKD / CS-C9GKD / CU-C9GKD / CS-C12GKD / CU-C12GKD Service Manual ↓ Size: 5.69 MB | Pages: 64 in PDF or view online for FREE

Model
CS-C7GKD CU-C7GKD CS-C9GKD CU-C9GKD CS-C12GKD CU-C12GKD
Pages
64
Size
5.69 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-c7gkd-cu-c7gkd-cs-c9gkd-cu-c9gkd-cs-c12gkd-cu-c.pdf
Date

Panasonic CS-C7GKD / CU-C7GKD / CS-C9GKD / CU-C9GKD / CS-C12GKD / CU-C12GKD Service Manual ▷ View online

9
Note:
• Specification are subjected to change without prior notice for further improvement.
 Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
Single
V 220
230
Hz
50
50
Input power
kW
1.11
1.13
Starting Current
A
27
27
Running Current
Cooling
A
5.3
5.2
Power Factor
Cooling
%
95
92
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
3 (1.5mm)
Length
m (ft)
2 (6)
Thermostat
Protection Device
Inner Protector
10
3 Features
• High Efficiency
• Compact Design
• Wider range of horizontal discharge air
• Air Filter with function to reduce dust and smoke
• Automatic air swing and manual adjusted by Remote
Control for vertical airflow
• Long Installation Piping
CS/CU-C7GK, CS/CU-C9GK, long piping up to 10 meter
CS/CU-C12GK, long piping up to 15 meter
• e-ion Air Purifying System with Patrol Sensor
- Discharged Active e-ions capture dust particles and
bring it back with a boomerang-like mechanism
• Quality Improvement
Random auto restart after power failure for safety restart
operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect Compressor
- Noise prevention during soft dry operation
Blue Coated Condenser for high resistance to corrosion
• Operation Improvement
Quiet mode to provide quiet operation
- Powerful mode to reach the desired room temperature
quickly
- 24-hour timer setting
• Serviceability Improvement
Removable and washable front panel
11
4 Location of Controls and Components
4.1.
Product Overview
4.1.1.
Indoor Unit
4.1.2.
Outdoor Unit
4.1.3.
Remote Control
12
5 Dimensions
5.1.
Indoor Unit & Remote Control
5.1.1.
CS-C7GK CS-C9GK CS-C12GK
Page of 64
Display

Click on the first or last page to see other CS-C7GKD / CU-C7GKD / CS-C9GKD / CU-C9GKD / CS-C12GKD / CU-C12GKD service manuals if exist.