Panasonic CS-C7GKD / CU-C7GKD / CS-C9GKD / CU-C9GKD / CS-C12GKD / CU-C12GKD Service Manual ▷ View online
13
5.2.
Outdoor Unit
5.2.1.
CU-C7GK CU-C9GK
5.2.2.
CU-C12GK
14
6 Refrigeration Cycle Diagram
15
7 Block Diagram
16
8 Wiring Connection Diagram
8.1.
CS-C7GK CU-C7GK / CS-C9GK CU-C9GK / CS-C12GK CU-C12GK
Resistance of Indoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25
°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20
°C of ambient temperature.
Note: Resistance at 20
°C of ambient temperature.
MODEL
CS-C7GK
CS-C9GK
CS-C9GK
CS-C12GK
CONNECTION
CWA921181J
BLUE-YELLOW
390.0
Ω
YELLOW-RED
394.0
Ω
MODEL
CU-C7GK
CU-C9GK
CU-C12GK
CONNECTION
CWA951378J
CWA951503
CWA951217J
BLUE-YELLOW
287
Ω
353
Ω
281
Ω
YELLOW-RED
238
Ω
258
Ω
251
Ω
MODEL
CU-C7GK
CU-C9GK
CONNECTION
2RS122D5BC02
2PS156D3DA02
C - R
5.193
Ω
4.228
Ω
C - S
5.557
Ω
3.841
Ω
MODEL
CU-C12GK
CONNECTION
2KS206D5AF04
C - R
2.234
Ω
C - S
2.630
Ω
Click on the first or last page to see other CS-C7GKD / CU-C7GKD / CS-C9GKD / CU-C9GKD / CS-C12GKD / CU-C12GKD service manuals if exist.