Panasonic CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD Service Manual ▷ View online
Unit
CS-A24DKD
CU-A24DKD
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 × 15
2 × 28
FPI
21
18
Size (W × H × L)
mm
810 × 315 × 25.4
827.7
862.2
862.2
× 711.2 × 44.0
Refrigerant Control Device
—
Capillary Tube
Refrigeration Oil
(cm
3
)
—
SUNISO 4GDID or ATMOS
M60 or ATMOS 56M
Refrigerant (R-22)
g (oz)
—
2,050 (72.4)
Thermostat
—
—
Protection Device
—
Inner Protector
Capillary Tube
Length
mm
—
Cooling; 730, Heating; 340
Flow Rate
l/min
—
Cooling; 12.5, Heating; 21.0
Inner Diameter
mm
—
Cooling; 1.6, Heating; 2.0
Air Filter
Material
Style
Style
P.P.
Honeycomb
—
Capacity Control
Capillary Tube
Compressor Capacitor
µF, VAC
—
45 µF, 400/440VAC
Fan Motor Capacitor
µF, VAC
—
3.5 µF, 440VAC
Note:
• Specifications are subject to change without notice for further improvement.
• Specifications are subject to change without notice for further improvement.
9
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
4 Dimensions
4.1. Indoor Unit & Remote Control
4.1.1. CS-A18DKD CS-A24DKD
10
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
4.2. Outdoor Unit
4.2.1. CU-A18DKD CU-A24DKD
11
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
5 Refrigeration Cycle Diagram
12
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Click on the first or last page to see other CS-A18DKD / CU-A18DKD / CS-A24DKD / CU-A24DKD service manuals if exist.