DIAGNOSTIC TEST
10
Test 6 Thermister check
Trouble Symptom : Poor drying performance(over-drying or no drying). Abnormal
thermistor operation.
Measurement condition : Power cord is unplugged.
Dryer
Temperature
Temperature
• Check harness & connection
Dryer
Temperature
Temperature
Resistance
TH-Heater
250~180kΩ
180~113kΩ
TH-Drum
19~111kΩ
11~8kΩ
8~5kΩ
TH-Drum
19~111kΩ
11~8kΩ
8~5kΩ
Resistance
Remark
TH1
113~75kΩ
75~50kΩ
50kΩ
TH2
5~4kΩ
4~2.5kΩ
2.5kΩ
10
20~30
30~40
Dryer
Temperature
Temperature
40~50
50~60
60
With White9,White 6 disconnected from
Controller, check
1) High temperature thermistor ( Wire
Controller, check
1) High temperature thermistor ( Wire
color : White) White 6 pin
white ~White
6 pin
red resistance ranges table data
according to surrounding temperature.
2) Low temperature thermistor ( Wire
color : Blue) White 9 pin
Blue ~White 9
pin
white resistance ranges table data
according to surrounding temperature.
• Check and replace
thermistor.
1) Check disconnected
Housing or severed
Wire.
2) Check the resistance
of thermistor.
3) Replace controller
and then recheck,
if anything else
occurs.
if anything else
occurs.
29
DIAGNOSTIC TEST
10
6AIJ %
With White 9 disconnected from
controller, White 9 pin ③ - White 9
pin ⑨
Resistance is unlimited?
③ : Green wire
⑨ : Orange wire
With metal tape attached to
sensor tips, White10pin ⑧ -
White10pin ⑩
resistance is less than 10Ω ?
After making damp clothes touch
sensor tips, the range are within
the below table in LQC test mode.
30
DIAGNOSTIC TEST
10
Test 8
Check if they are working while being connected to power supply.
Is the product leveled?
(Check shaking / tilt )
(Check shaking / tilt )
Is it installed to Built In / Under
environment?
environment?
Is thermistor normal?
Is comp operation properly?
1) Power On
2) Display dataview mode
3) Comp on after 1min from start.
4) After comp on, check
corresponding the temp.
-. Comp T : Is it rising?
-. Eva in : Is it rising after falling?
1) Power On
2) Display dataview mode
3) Comp on after 1min from start.
4) After comp on, check
corresponding the temp.
-. Comp T : Is it rising?
-. Eva in : Is it rising after falling?
1. Is OLP normal?
2. Is Comp resistance normal?
3. Is capacitor resistance normal?
(refer to page 16)
4. Is LEV resistance normal?
5. Check trace of oil leakage around
Comp.
2. Is Comp resistance normal?
3. Is capacitor resistance normal?
(refer to page 16)
4. Is LEV resistance normal?
5. Check trace of oil leakage around
Comp.
2.For Comp defect
-. Replace Comp
(Refer to R code - C145 , Page 45)
3. For LEV defect
-. Replace LEV.
-. Replace Comp
(Refer to R code - C145 , Page 45)
3. For LEV defect
-. Replace LEV.
Is thermistor resistance normal?
(Refer to resistance and
measurement method,
page 15~17)
(Refer to resistance and
measurement method,
page 15~17)
Replace thermistor.
Improve dryer installation environment.
( Refer to installation environment,
Page 10~12 )
( Refer to installation environment,
Page 10~12 )
Leg leveling
(Refer to how to adjust leveling,
Page 10 )
(Refer to how to adjust leveling,
Page 10 )
Check Evaporator clogging status
( Refer to humidity sensor inspection
method, Page 30 )
method, Page 30 )
Does the defect occur after PCB
replacement ?
replacement ?
Clean filter.
Clean Evaporator clogging.
(Refer to exploded view , Page 45)
Clean Evaporator clogging.
(Refer to exploded view , Page 45)
NO
The course
Show details
1
2
3
4
5
6
7
8
9
10
11
12
Refresh
Skin Care
Jeans
Bulky Item
Easy Care
Mixed Fabric
Cotten
Sports Wear
Quick Dry
Delicate
Wool
Rack Dry
Humidity values
Low Temp
Comp Temp
T_heater (High Thermistor)
Eva in Temp
Sump Water Level
Drain Pump RPM
LEV Pulse
Main PGM Tool
Main Version
※Check the status of the actions Sensor
- Drum Light + Buzzer 3 when entering Pressing enter,
Once again press the same key fot three seconds
to escape.
- Turn the Jog Dial in data view state data can be
checked as shown below.
- Not to enter the Child lock status.
- Apply the model : Only Touch LED model.
- Drum Light + Buzzer 3 when entering Pressing enter,
Once again press the same key fot three seconds
to escape.
- Turn the Jog Dial in data view state data can be
checked as shown below.
- Not to enter the Child lock status.
- Apply the model : Only Touch LED model.
31
DIAGNOSTIC TEST
10
Test 9
* Standard Time: Eco Mode
→ Over 225min, Speed: Over 180min
* Drying Condition: Cotton-Cupboard, 9kg Cotton Clothes, Spin rpm: Over 1,000rpm
Measurement condition : Check if they are working while being connected to power supply.
Is the product leveled? (Check shaking / tilt )
3) Is it installed to Built in / Under environment?
Improve dryer installation
environment.
(Refer to installation environment,
Page 10~12)
1.Check resistance
2.Check harness & connection.
2.Check harness & connection.
1. Is OLP normal?
2. Is Comp resistance normal?
3. Is capacitor resistance normal?
(refer to page 16)
4. Is LEV resistance normal?
5. Check trace of oil leakage around Comp.
2. Is Comp resistance normal?
3. Is capacitor resistance normal?
(refer to page 16)
4. Is LEV resistance normal?
5. Check trace of oil leakage around Comp.
( Refer to humidity sensor inspection
method, Page 30 )
method, Page 30 )
Does the defect occur after PCB
replacement ?
replacement ?
2.For Comp defect
-. Replace Comp
(Refer to R code - C145 , Page 45)
3. For LEV defect
-. Replace LEV.
-. Replace Comp
(Refer to R code - C145 , Page 45)
3. For LEV defect
-. Replace LEV.
4) After Comp on, check corresponding
thermistor temp.
thermistor temp.
Release thermostat trip or replace thermostat.
Replace heater or repair connection.
Leg leveling
(Refer to how to leveling, Page 10)
NO
The course
Show details
1
2
3
4
5
6
7
8
9
10
11
12
Refresh
Skin Care
Jeans
Bulky Item
Easy Care
Mixed Fabric
Cotten
Sports Wear
Quick Dry
Delicate
Wool
Rack Dry
Humidity values
Low Temp
Comp Temp
T_heater (High Thermistor)
Eva in Temp
Sump Water Level
Drain Pump RPM
LEV Pulse
Main PGM Tool
Main Version
※Check the status of the actions Sensor
- Drum Light + Buzzer 3 when entering Pressing enter,
Once again press the same key fot three seconds
to escape.
- Turn the Jog Dial in data view state data can be
checked as shown below.
- Not to enter the Child lock status.
- Apply the model : Only Touch LED model.
- Drum Light + Buzzer 3 when entering Pressing enter,
Once again press the same key fot three seconds
to escape.
- Turn the Jog Dial in data view state data can be
checked as shown below.
- Not to enter the Child lock status.
- Apply the model : Only Touch LED model.
32