LG F1236RDSG Service Manual ▷ View online

16
ERROR
SYMPTOM CAUSE
• The connector in the LEAD WIRE ASSEMBLY is not connected to
the connnector of STATOR ASSEMBLY
Reconnect or repair the connector
• The hall sensor is out of order/defective.
Replace the STATOR ASSEMBLY
• The Dry Heater is out of order
Replace the Dry Heater
• The Connector of the Dry Heater is not connected properly to the
connector in the Main PWB ASSEMBLY
Reconnect or repair the connector
• The Dry fan motor is out of order
Replace the fan Motor.
MOTOR
ERROR
DRY
HEATOR
ERROR
• The washer experienced a power failure.
11
POWER
FAILURE
• EEPROM is out of order.
Displayed only when the START/PAUSE button is first
pressed in the QC Test Mode.
10
9
8
EEPROM
ERROR
17
8-1.DIAGNOSIS AND ANSWER FOR ABNORMAL OPERATION
8. ERROR DIAGNOSIS AND CHECK LIST
SYMPTOM
GUIDE FOR SERVICE CALL
NO POWER 
Water inlet trouble
Is the power plug connected firmly to 
110 V a.c Outlet?
Power failure? or Breaker opened?
Visit to check 
Is "       " displayed?
Is the tap opened?
Is the tap frozen?
Is the water supply shut-off?
Is filter in the inlet valve clogged with
foreign material?
Visit to check 
Clean the filter of
inlet valve
18
19
SYMPTOM                                                        GUIDE FOR SERVICE CALL
Suds overflow from the
appliance.
(In this condition, wash and 
spin do not operate 
normally)
No effect of softener
Is low-sudsing detergent for the drum
washing machine used?
Is the proper amount of detergent used 
as recommended?
Recommend to reduce the using amount 
of detergent.
Is softener put in the correct compartment of
the  drawer?
Is the drawer closed during wash?
Is the softener cap clogged?
Explain how to use softener
< Clean the compartment for softener >
Visit to check 
LOW-SUDSING
This appliance has the automatic suds sensing function which
operates under much suds condition for good rinse and
preventing overflow.
When much suds are sensed, suds removing function such as
drain, water input and pause will operate without rotating the
drum.
Page of 44