7-2-2 OSCILLATION CIRCUIT
This circuit is to generate the base clock for calculating time and the synchro clock for transmitting data from and to the
inside logic elements of the IC1(MICOM).  Be sure to use the authentic parts since the calculating time by the IC1 may be
changed or it will not work if the OSC1 SPEC is changed.
7-2-3 RESET CIRCUIT
The RESET circuit is for allowing all the functions to start at the initial conditions by initializing various parts including the
RAM inside the MICOM (IC1) when the power is initially supplied or the power supply to the MICOM is restored after a
momentary power failure.  For the initial 10ms of power supply, ‘LOW’ voltage is applied to the MICOM RESET terminal.
During a normal operation, 5V is applied to the RESET terminal. (If a trouble occurs in the RESET IC, the MICOM will not
work.)
- 20 -
7-2-4 LOAD DRIVE CIRCUIT
1. Load Drive Condition Check
- 21 -
Load Type
Defrosting Heater
Refrigerator Fan
Measurement Location(IC5)
No.13
No.10
No.12
ON
1V or below
Condition
OFF
12V
Comp,
Freezer Fan Motor
7-2-5 TEMPERATURE SENSOR CIRCUIT
The upper CIRCUIT reads REFRIGERATOR temperature and DEF-SENSOR temperature for defrosting into MICOM.
OPENING or SHORT state of each TEMPERATURE SENSOR are as follows.
7-2-6 DOOR OPEN DETECTING CIRCUITS
- 22 -
SENSOR
CHECK POINT
NORMAL(-30 °C ~ 50 °C)
SHORT-CIRCUITED
OPEN
Refrigerator Sensor
POINT
Voltage
0.5 V ~ 4.5 V
0 V
5 V
Defrosting Sensor
POINT
Voltage
A
B
MEASURING POINTS
Freezer / Refrigerator Door
CLOSED
OPEN
IC1 (Pin No. 8)
5 V
0 V
- 23 -
7-2-7 TEMPERATURE COMPENSATION & OVERCOOLING/UNDERCOOLING COMPENSATION CIRCUIT
1. Refrigerator Temperature Compensation
Table of Temperature Compensation by adjusting the resistance (Difference with the current temperature)
E.g.) If the refrigerator compensation resistance (RCR1) is changed from 10K (the current resistance) to 18K 
(the adjustment resistance), the temperature of the refrigerator rises +1 °C.
Refrigerator
Resistance
Temperature Remark
(RCR1)
Compensation
180 K
+2.5 °C
Compensation by
56 K
+2.0 °C
raising the 
33 K
+1.5°C
temperature
18 K
+1.0 °C
12 K
+0.5 °C
10 K
0 °C
Standard Temperature
8.2 K
-0.5°C
Compensation by
5.6 K
-1.0°C
lowering the
3.3 K
-1.5 °C
temperature
2 K
-2.0 °C
470 
-2.5 °C