LG GR-S512QVC Service Manual ▷ View online
7-2-8 KEY BUTTON INPUT & DISPLAY LIGHT ON CIRCUIT
➧
The circuit shown above is to determine whether a function control key on the operation display is pushed and to turn on
the corresponding function indication LED. The drive type is the scan type.
the corresponding function indication LED. The drive type is the scan type.
- 24 -
- 25 -
7-3 RESISTANCE SPECIFICATION OF SENSOR
• The resistance of SENSOR has ±5% common difference.
• Measure the resistance of SENSOR after leaving it over 3 minutes in measuring temperature.
• Measure the resistance of SENSOR after leaving it over 3 minutes in measuring temperature.
This postponing is necessary because of perceiving speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE SENSOR
RESISTANCE OF REFRIGERATOR
(DEFROST) SENSOR
- 20 ˚C
77 K
Ω
- 15 ˚C
60 K
Ω
- 10 ˚C
47.3 K
Ω
- 5 ˚C
38.4 K
Ω
0 ˚C
30 K
Ω
+ 5 ˚C
24.1 K
Ω
+ 10 ˚C
19.5 K
Ω
+ 15 ˚C
15.9 K
Ω
+ 20 ˚C
13 K
Ω
+ 25 ˚C
11 K
Ω
+ 30 ˚C
8.9 K
Ω
+ 40 ˚C
6.2 K
Ω
+ 50 ˚C
4.3 K
Ω
- 26 -
7-4 TROUBLE SHOOTING
• Replace PCB when no trouble after checking the contents of trouble.
CLASSIFICATION
STATE OF TROUBLE
POINT BE CHECKED
CHECKING METHOD
CONTENT
REMEDY
POWER SOURCE
1. All the DISPLAY
1. FREEZER/
FREEZER/REFRIGERATOR
POWER SOURCE is poor
Certify Fuse.
is poor
LED
OFF
REFRIGERATOR
DOOR OPEN
Certify outlet Voltage.
2. DISPLAY LED
2. LAMP is dim.
CHECK with the naked.
Applied voltage mistake
Use boosting TRANS.
represents abnormal
3. The connection of
Certify connection of
CONNECTOR connection
Reconnect CONNECTOR.
operation.
CONNECTOR of MAIN PWB.
CONNECTOR.
is poor.
TRANS FUSE open.
Replace TRANS.
COOLING is poor
NO COOLING
1. COMPRESSOR operates?
Check the MAIN PCB.
COMPRESSOR lock or
Replace COMPRESSOR.
blocked.
OLP, PTC is poor.
Replace OLP, PTC.
COMPRESSOR RELAY is
Replace MAIN PWB RY1
poor
THE CONNECTING WIRE
Certify the black wire of MAIN
is poor.
PWB CONNECTOR (CON1)
2. Whether refrigerant leaks or
Measure the amount of frost
Refrigerant leakage.
Remedy the leaking part
leaks or not.
sticking on EVA and the
and reaching Refrigerant.
surface temperature of
condenser pipe.
FREEZER
1. Whether FAN
MOTOR
Check the MAIN PCB.
FAN MOTOR is poor
Replace FAN MOTOR.
TEMPERATURE is poor
operates or not.
DOOR LINE contact.
Replace DOOR LINER.
CONETTING WIRE is poor.
Certify MOTOR and the
connection of the black wire
of MAIN PWB CONNECTOR.
(CON1)
2. DEFROSTING normal?
Certify the amount of frost
DEFROSTING is poor.
See the DEFROSTING
sticking on EVA.
trouble.
3. SENSOR normal?
Check resistance the
SENSOR RESISTANCE is
Replace SENSOR
SENSOR in the
poor.
Refrigerator
- 27 -
CLASSIFICATION
STATE OF TROUBLE
POINT BE CHECKED
CHECKING METHOD
CONTENT
REMEDY
COOLING is poor.
REFRIGERATOR
1. FREEZER TEMPERATURE
See "FREEZER
Certify the attaching state
TEMPERATURE is
is normal?
TEMPERATURE is poor".
of DOOR.
poor.
2. Cool air of FAN MOTOR is
Certify the amount of cool air
FAN MOTOR is poor.
Replace FAN MOTOR.
is sufficient?
and its speed touching check
Passage of cool air blocking.
Remove impurities.
supplied into
REFRIGERATOR
EVA frozen.
See "DEFROSTING is poor".
DEFROSTING is
NO DEFROSTING.
1. HEATER emit heat?
Check the MAIN PCB.
HEATER disconnection.
Replace HEATER.
poor.
TEMPERATURE FUSE
Replace TEMPERATURE
disconnection.
FUSE.
Connection is poor.
Certify EVA connection and
wire of MAIN PWB
CONNECTOR (CON1)
DEF-SENSOR is poor.
Replace DEF-SENSOR.
HEATER RELAY is poor.
Replace RY4 of MAIN PWB.
2. DRAIN PIPE blocking?
Certify DRAIN PIPE.
DRAIN PIPE blocking.
Remove ice and impurities.
Certify HEATER PLATE
resistance.
3. Remain ice at
Certify the attaching
Attaching is poor.
Reassemble DEF-SENSOR.
DEFROSTING?
of DEF-SENSOR.
Certify the attaching
DOOR sticking is poor.
Reassemble DOOR.
state(gap) of FREEZER/
Replace GASKET.
REFRIGERATOR DOOR.