LG GR-S512QVC Service Manual ▷ View online
7-5 MAIN PWB ASSEMBLY AND PARTS LIST
7-5-1 MAIN PWB ASSEMBLY
- 28 -
- 11 -
6-2 PTC AND OLP
6
5
3
4
YES
NO
Normal operation of
Compressor is
impossible or poor.
Compressor is
impossible or poor.
Separate the PTC from
Compressor and
measure the resistance
between No. 5 and 6
(only RSIR Type) or No.
4 and 5 of PTC with a
Tester or Whistone
Bridge. (Figure 22)
Compressor and
measure the resistance
between No. 5 and 6
(only RSIR Type) or No.
4 and 5 of PTC with a
Tester or Whistone
Bridge. (Figure 22)
Separate the OLP
from Compressor and
check resistance
value between two
terminals of OLP with
a Tester. (Figure 23)
from Compressor and
check resistance
value between two
terminals of OLP with
a Tester. (Figure 23)
Observation value is
220V/50Hz : 22
220V/50Hz : 22
Ω
±30%
115V/60Hz : 6.8
Ω
±30%
240V/50Hz : 33
Ω
±30%
127, 220V/60Hz :
22
Ω
±30%
The resistance value is
0 or several
hundreds
0 or several
hundreds
Ω
.
The value is
∞
.
Check another
electric components.
electric components.
Replace OLP.
Check another
electric components.
electric components.
Replace
PTC.
PTC.
Figure 23
Figure 22
7-5-2 REPLACEMENT PARTS LIST
- 29 -
7-5-3 PWB ASSEMBLY, DISPLAY AND PARTS LIST
- 30 -
Click on the first or last page to see other GR-S512QVC service manuals if exist.