LG GR-267 Service Manual ▷ View online
MICOM FUNCTION AND CIRCUITS
- 53 -
5. PWB circuit drawing- The PWB circuit drawing may change without notice.
MICOM FUNCTION AND CIRCUITS
- 52 -
(HOME BAR-SENSOR)
(FREEZER-SENSOR)
(DEFROST-SENSOR)
MACHINE ROOM-FAN
MOTOR
DEFROST–HEATER
R-DOOR SWITCH
F-DOOR SWITCH
Refrigerator Compartment
Temperature Compensation
Freezer Compartment
Temperature Compensation
R20 10K
(VEGETABLE DUCT)
56
57
Freezer
Temp
Control
Refrigerator
Temp
Control
Power
Freezer
Crushed/Water/Cube
2-6. Forced starting, forced defrost buzzer sound
1. If test button in main PWB is pressed, it will sound “beep”.
2. If forced starting is selected, warning cycle will be repeated three times. Each cycle has on for 0.2 second and off for 1.8
seconds.
3. If forced defrost is selected, warning cycle will be repeated three times. Each cycle has on for 0.2 second, off for 0.2
second, on for 0.2 second and off for 1.4 seconds.
2-7. Defrost Function
1. Defrost starts when compressor operation time reaches between seven hours and seven hours and twenty minutes.
2. Defrost starts when compressor operation time reaches between four hours and four hours and twenty minutes when
power is first on or after a power cut.
3. Defrost shall stop when the defrost sensor temperature is more than 10
°
C. If the temperature of defrost sensor does not
reach to 10
°
C after two hours, faulty defrost will be displayed.
4. If defrost sensor is faults (wire cut or short-circuit), defrost is not working.
2-8. Electric Equipment Progressive Operation
Compressor, defrost heater, cooling fan (high speed), cooling fan (standard), electromagnetic single motor damper, etc. start
in the following sequence in order to protect noise and parts damage when power is first applied and when test is complete.
in the following sequence in order to protect noise and parts damage when power is first applied and when test is complete.
MICOM FUNCTION AND CIRCUITS
- 32 -
Function
Load Starting Sequence
Remarks
When
electricity
is
first
first
applied
TEST
MODE
When the
temperature of
defrost sensor is
above 10
temperature of
defrost sensor is
above 10
°
C
(when purchased
or moved to
another house)
another house)
If there is error in
function, initial
starting does not
work.
function, initial
starting does not
work.
■
Load starting
sequence when
freezer and
refrigerator doors
are closed.
sequence when
freezer and
refrigerator doors
are closed.
If switch is one more
pressed or the
temperature of
defrost sensor is
above +5
pressed or the
temperature of
defrost sensor is
above +5
°
C in test
mode 2, it returns to
test mode and start
initial driving.
(compressor will start
after seven minutes)
test mode and start
initial driving.
(compressor will start
after seven minutes)
When the
temperature of
defrost sensor is
below 10
temperature of
defrost sensor is
below 10
°
C
(during power cut
and service)
Test Mode 1
(Forced Starting)
(Forced Starting)
Test Mode 2
(Forced Defrost)
(Forced Defrost)
POWER
ON
COMP
ON
FAN
(High Speed)
ON
MOTOR
DAMPER
ON
HOME
BAR
HEATER
ON
POWER
ON
DEFROST
HEATER
ON
HOME
BAR
HEATER
ON
HOME
BAR
HEATER
ON
VEGETABLE
HEATER
DAMPER
HEATER
ON
COMP
ON
FAN
ON
MOTOR
DAMPER
ON
VEGETABLE
HEATER
DAMPER
HEATER
OFF
TEST
S/W
(Press
Once)
COMP
ON
FAN
(High Speed)
ON
MOTOR
DAMPER
ON
TEST
S/W
(Press
Twice)
Twice)
COMP
OFF
FAN
OFF
MOTOR
DAMPER
ON
0.5
sec
0.3
sec
0.3
sec
0.3
sec
0.5
sec
10
sec
0.3
sec
5
sec
DEFROST
HEATER
OFF
5
sec
0.3
sec
20
sec
0.3
sec
0.3
sec
0.3
sec
0.3
sec
0.3
sec
0.3
sec
0.3
sec
0.3
sec
OTHER
LOAD
OFF
DEFROST
HEATER
ON
2-9. Trouble Diagnosis Function
1. Trouble diagnosis function provides easy service when refrigerator is out of order during use.
2. When the refrigerator is out of order, the function does not carry on even function control button is pressed but
recognition sound (bell sounds) shall be heard.
3. If troubles are solved, it returns to normal operation. (reset)
4. Trouble code is shown in the freezer temperature indicator LED in the refrigerator control display and all LEDs except
trouble code are off.
MICOM FUNCTION AND CIRCUITS
- 33 -
F4
F3
F2
F1
F3
F2
F1
F
R
FRZ
TEMP
REF
TEMP
POWER
FRZ
SELECT
FRZ
TEMP
A
B
D
E
C
Trouble Code
Index
Trouble Code Index
Operation Status During Trouble
No.
Trouble Items
Troubles
Freezer
Defrost
Electronic single
F1 F2 F3 F4
Compressor
Fan
Heater
Damper
1
Abnormal freezer (F)
Freezer sensor is cut or short-circuited
15 min on/ Standard
●
●
●
●
sensor
15 min off
RPM
2
Abnormal refrigerator
Upper shelf refrigerator sensor is cut or
●
●
Standard
●
●
Note 2)
sensor 1 (R1) (upper
short-circuited.
RPM
shelf in the refrigerator)
3
Abnormal refrigerator
Note 1)
Lower shelf refrigerator sensor is cut or
●
●
Standard
●
●
●
●
sensor 2 (R2) (lower
short-circuited.
RPM
shelf in the refrigerator)
4
Abnormal defrost
Defrost sensor is cut or short-circuited
●
●
Standard No defrost
●
●
sensor
RPM
5
Faulty defrost
Defrost heater and temperature fuse are
●
●
Standard
●
●
●
●
cut and disconnected. (indicates after at
RPM
least four hours when troubles occur)
6
Abnormal electronic
Faulty damper motor. Lead wire of
●
●
Standard
●
●
single motor damper
damper lead switch is cut or short-circuited.
RPM
Interference of foreign materials in damper
baffle or EPS
baffle or EPS
7
Abnormal room
Note 1)
Room temperature sensor is cut or
●
●
●
●
●
●
●
●
temperature
short-circuited.
sensor.
8
Abnormal home bar
Note 1)
Home bar sensor is cut or short-circuited.
●
●
●
●
●
●
●
●
sensor
9
Abnormal icemaker
Note 1)
Icemaker sensor is cut or short-circuited.
●
●
●
●
●
●
●
●
sensor
10
Abnormal icemaker
Note 1)
Faulty motor or hall IC in icemaker unit.
●
●
Standard
●
●
●
●
unit.
Lead wire is cut or short-circuited.
RPM
Faulty motor driving circuits
:On
:Off
Check
operation
every hour
and reset
when it is
normal.
operation
every hour
and reset
when it is
normal.
Note 1) The abnormality of room temperature sensor, refrigerator sensor 2, Home Bar Sensor, Icemaker Unit, and Icemaker
Sensor is not indicated in trouble code but it is indicated when checking LED (when pressing both freezer
temperature control button and power freeze button for more than one second at the same time).
temperature control button and power freeze button for more than one second at the same time).
Room Temperature Detection Sensor
Normal : A LED On
Abnormal : A LED Off
Refrigerator Sensor 2 (lower shelf)
Normal : B LED On
Abnormal : B LED Off
Home Bar Sensor
Normal : C LED On
Abnormal : C LED Off
Ice maker Unit
Normal : D LED On
Abnormal : D LED Off
Icemaker Sensor
Normal : E LED On
Abnormal : E LED Off
Note 2) If upper shelf refrigerator sensor is faulty, it is opened for 10 minutes and closed for 10 minutes.
2-10. Test Function
1. Test function is to check functions of PWB and products and to find faulty parts in the refrigerator.
2. Test switch is on the main PWB in the refrigerator. Test mode completes and returns to the normal conditions after two
hours in maximum.
3. During the test mode, function control button is not detected but button recognition sounds (bell sounds) are heard.
4. Please unplug power cord and then plug into the wall outlet to get normal conditions after test mode is completed.
5. If abnormal sensor is detected during test mode, test mode is canceled and trouble code is indicated.
6. Test mode does not work even test switch is pressed when it indicates trouble code.
MICOM FUNCTION AND CIRCUITS
- 34 -
Mode
Handling
Contents
Remarks
Test 1
Press test switch once.
1. Compressor continuously operates.
2. Freezer fan (high speed RPM) continuously
operates.
3. Defrost Heater is off.
4. All display LEDs are on.
5. Electronic single motor damper is in open
conditions.(baffle is open.)
Test 2
Press test switch once at
1. Compressor is off.
It returns to normal
test mode 1 conditions.
2. Freezer fan is off.
conditions when the
3. Defrost heater is on.
temperature of defrost
4. All display LEDs are off.
sensor is above 10
°
C.
(Freezer room A and Refrigerator room B
are only on.)
5. Electronic single motor damper is all closed.
(baffle is closed.)
Normal
Press test switch once
Returns to the initial conditions.
Compressor starts after
Conditions
at test mode 2 conditions.
seven minutes delay.
Click on the first or last page to see other GR-267 service manuals if exist.