—6—
Dimensions
(1) Indoor Unit 
(2) Outdoor Unit
Tubing hole cover
Air Inlet
Cooled Air Outlet
Tubing hole cover
Tubing hole cover
Liquid side
2-way valve
Gas side
3-way valve
—7—
Refrigeration Cycle Diagram
Pipe size(Diameter: Ø)
Max.
Max.
MODEL
Piping length
Elevation
Gas
Liquid
(m)
(m)
LS-H0560CL
3/8"
1/4"
7
5
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
ACCUMU
LATOR
GAS SIDE
3-WAY VALVE
LIQUID SIDE
2-WAY VALVE
CAPILLARY TUBE
COOLING
HEATING
REVERSING
VALVE
Wiring Diagram
(1) Indoor Unit
(2) Outdoor Unit
—8—
INDOOR WIRING DIAGRAM
TO OUTDOOR UNIT
PILLAR
TERMINAL
MAIN PCB 
ASM
1(L)   2(N)
DISPLAY PCB ASM
CN-DISP
RY-COMP
MOTOR
MOTOR
SH-CAPA
BL
BR
OR
BK
SSR
GN/YL
BL
BR
GN/YL
BL
CN-POWER
BR
YL
GN/YL
CN-FAN
CN-E/RI
CN-UP/DOWN
BR
STEP
MOTOR
LE/RI
STEP
MOTOR
UP/DOWN
CN-TH
FUSE T2A
THERMISTOR
F
C
H
BL
R
S
C
COMP.
FAN
MOTOR
BL
CAPACITOR
RD
TO INDOOR UNIT
OUTDOOR WIRING DIAGRAM
RD
BR
OLP
BR
YL
PILLAR
TERMINAL
BL
1(L)   2(N)
1
GN/YL
BL
BR
GN/YL
BL
BR
Operation Details
(1) The function of main control
1. Time Delay Safety Control
• 3min.; The compressor operation is delayed for 3 minutes to balance the pressure of cycle.
(Protection of compressor)
• 5sec.; The indoor fan is delayed for 5 seconds, when operating initially, to prevent noises occurred by the vertical
louver and wind.
2. Airflow Direction Control
• This function is to swing the vertical louver up and down automatically and to set it at a fixed position.
• The procedure is as the following.
1st ; Press the ON/OFF Button to operate the unit.
2nd ; Press the Airflow Direction Control Button to swing the vertical louver up and down automatically.
3nd ; Repress the Airflow Direction Control Button to set the vertical louver at a fixed position.
3. Cooling Mode Operation
• When selecting the Cooling(
) Mode Operation, the unit will operate according to the setting by the
remote controller and the operation diagram is shown below.
CLOSED
8
7
6
5
4
3
2
1
OPEN
Setting point: 
108°
INTAKE AIR TEMP.
SETTING TEMP. +0.5
°
C
(Compressor ON)
SETTING TEMP. -0.5
°
C
(Compressor OFF)
More than
3 minutes
More than
3 minutes
INDOOR FAN SPEED
COMPRESSOR
Selecting
fan speed
Selecting
fan speed
Selecting
fan speed
Low
ON
OFF
ON
ON
OFF
Low
—9—
Page of 48