—10—
5. Forced operation
• If you lose wireless remote controller, you can operate the unit with forced operation switch.
• The standand conditions are as following. 
Cooling Model
Operation Mode
Cooling
Indoor FAN Speed
High
Setting temp.
22°C
4. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compres-
sor OFF temperature is the setting temperature minus 0.5°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to
the Cooling operation.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
INDOOR FAN
LOW
Selecting
fan speed
ON
ON
ON
OFF
OFF
Operation
Cooling
Dry Operation
COMPRESSOR
SETTING TEMP.+1
°
C
(COMP. ON)
SETTING TEMP.-0.5
°
C
(COMP. OFF)
10 minutes
2 minutes
58 seconds
2 minutes
58 seconds
maximum
10 minutes
maximum
4 minutes
5. Cooling Mode OFF-Timer Operation
• When selecting the Cooling(
), the operation diagram is as following.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
INDOOR FAN SPEED
Setecting
fan speed
Setecting
fan speed
Setecting
fan speed
Low
Low
ON
OFF
ON
More than
3 minutes
More than
3 minutes
ON
OFF
COMPRESSOR
SETTING TEMP.+0.5
°
C
(Compressor ON)
SETTING TEMP.-0.5
°
C
(Compressor OFF)
—11—
Display Function
• Lights up during cooling operation.
• Lights up during soft dry operation.
• Lights up during timer operation.
Cooling Indicator
Soft Dry Indicator
Timer Indicator 
—12—
1) Selection of the best location 
1.  Indoor unit. 
• There should not be any heat source or steam
near the unit. 
• There should not be any obstacles to prevent the
air circulation.
• A place where air circulation in the room will be
good. 
• A place where drainage can be easily obtained.
• A Place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fance, or other obstacles. 
2.  Outdoor unit.
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat
radiation from the condenser is not restricted. 
• There should not be any animals or plants which
could be affected by hot air discharged. 
• Ensure the spaces indicated by arrows from the
wall, ceiling, fance, or other obstacles. 
More than 5cm
More than 5cm
More than 2.3m
More than 5cm
More than 10cm
More than 10cm
More than 60cm
More than 70cm
1. Installation of indoor, Outdoor unit 
Install the indoor unit on the wall where the height
from the floor is more than 2.3 meters.
CAUTION
—21—
2) Connect the cable to the indoor unit
1. Connect the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection. 
• Ensure that the color of wires of outdoor unit and
the terminal No. are the same to the indoor’s
respectively. 
1) Cooling only type
2. Attach the Grille onto the cabinet. 
• Grasp lower the left and the right side of the grille
and engage two tabs on the top inside edge of
the grille with two slots on the cabinet’s top front
edge. 
• Press the grille toward to the cabinet until it will
be back into place.
ƒT
The power cord connected to the indoor unit
should be complied with 1.0mm
2
conductors.
(Type H05VV-F, TÜV or VDE Approval)
ƒT
The connecting cable connected to the indoor and
outdoor unit should be complied with 1.0mm
2
conductors.
(Type H07RN-F, TÜV or VDE Approval)
Connecting cable
BROWN
1(L)           2(N)     
BLUE
GREEN/YELLOW
Terminals on the outdoor unit
Terminals on the indoor unit
Color of Wires
1(L)           2(N)     