5. Bend the tubing as shown in the figure and
bind the pipings, the connecting cables and the
drain hose altogether.
• Make a small loop for easy connection later.
6. Wrap the tubing, the drain hose and the 
connecting cable.
7. Indoor unit installation
• Hook the indoor unit onto the upper portion of
installation plate.(Engage the two hooks of the
rear top of the indoor unit with the upper edge of
the installation plate.)
Ensure the hooks are properly seated on teh
installation plate by moving it in left and right.
CAUTION : Take care to arrange the pipings, drain
hose and cables as the feature for
inserting it into the indoor unit and
mount the indoor unit on the installa-
tion plate.
—16—
Drain hose
Connecting
cable
Connecting 
cable
Gas side
piping
Liquid side
piping
Drain hose
Loop
Tape
Press the lower left and right side of the unit against
the Installation Plate until the hooks engages with
their slots (sound click). 
3. Insert the connecting cables, the drain pipe and
connecting pipings through the piping hole on
the wall.
4. Connect connecting pipings and indoor tubing,
and the drain hose and the drain pipe and place
the drain pipe into the chassis.
• Don’t connect the cable to the indoor unit.
• Make a small loop for easy conection later.
• Glue up the connection portion of drain hose and
drain pipe.
5. Bend the drain hose as shown in the figure and
bind the drain hose, the pipings and the
connecting cables altogeter.
—17—
For left rear pipings
Torque wrench
Spanner
Indoor unit tubing
Flare nut   Pipings
Drain hose
Adhesive
Drain pipe
Connecting cable
Connecting piping
Drain pipe
Indoor
Outdoor
,
,
Pipe Size     
Torque      
Liquid Side (1/4")
1.8kg·m  
Gas Side (3/8")  
4.2kg·m 
Loop
6. Wrap the insulation material around the
connecting portion. 
7. Wrap the tubing, the drain hose and the
connecting cable with tape.
8. Indoor unit installation. 
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indoor unit with the upper edge of
the installation plate,) 
Insure the hooks are properly seated on the
installation plate by moving it in left and right. 
—18—
Plastic Bands
• Wrap the insulation material around the
connecting portion.
Insulation material
Taping
Indoor/Outdoor
connecting cable
Connecting
cable
Gas side piping
Liquid side piping
Drain hose
Drain hose
Connecting
cable
Press the lower left and right side of the unit against
the Installation Plate until the hooks engages with
their slots (sound click). 
CAUTION :Take care to arrange the pipings,
drain hose and cables as the fea-
ture for inserting it into the
indoor unit and mount the indor
unit on the installation plate.
—19—
1) Connecting the pipings to the Outdoor
unit
1. Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks. 
• When tightening the flare nut with torque
wrench, ensure the direction for tightening fol-
lows the arrow on the wrench. 
2) Connection of the cable 
1. Remove the cover control from the unit by loosen-
ing the screw.
Connect the wires to the terminals on the control
board individually as the following. 
Cooling only type 
2. Secure the cable onto the control board with the
holder (clamper). 
3. Refix the cover control to the original position with
the screw. 
Liquid side piping
(Smaller Dia.)
Gas side piping
(Bigger Dia.) 
Torque wrench
Outdoor unit 
Connecting 
cable
Terminal block
(Pillar terminal)
Cover control
Outdoor unit
Over
5mm
Holder for 
connecting 
cable
3. Connecting Pipings and the cable to Outdoor unit 
Pipe Size     
Torque      
Liquid Side (1/4")
1.8kg·m  
Gas Side (3/8")  
4.2kg·m 
BROWN
1(L)           2(N)     
BLUE
GREEN/YELLOW
Terminals on the outdoor unit
Terminals on the indoor unit
Color of Wires