DOWNLOAD JBL SB 200 (serv.man3) Service Manual ↓ Size: 1.85 MB | Pages: 78 in PDF or view online for FREE

Model
SB 200 (serv.man3)
Pages
78
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-200-sm3.pdf
Date

JBL SB 200 (serv.man3) EMC - CB Certificate ▷ View online

Page 29 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal input), are 
subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna signal input), 
are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9 unless the floating secondary 
circuit is separated from the primary circuits by an earthed metal screen (e.g. in the power transformer), or the floating secondary 
circuit is connected to earth via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits to earth, see 
Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as required, then 
the value for clearance is used as the minimum creepage distance. 
"Min" = minimum required. 
"Actual = Actual dimensions measured. 
 
Page 30 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14 
TABLE: list of critical components and materials 
Pass 
 
Object / part 
No. 
Manufacturer/ 
trademark 
Type / model 
Technical data 
Standard 
Mark(s) of 
conformity
1)
Switching 
Transformer  
/ T5311-1 
Huizhou 
Jingquanli 
Electronics Co., 
Ltd. 
BCK-EC28-W-
5633 
Open, concentric 
winding  
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375J 
Phenolic, V-0, 
Minimum 0.9mm 
UL94 UL 
Insulation tape  Jingjiang Yahua 
Pressure 
Sensitive Glue 
Co., Ltd. 
CT 
130
°C 
UL510 UL 
-Alt. use- 
Switching 
Transformer  
/ T5311-1 
Huizhou 
Sunshine 
Electronics Co., 
Ltd. 
BCK-AJ140 
Open, concentric 
winding 
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375HF 
Phenolic, V-0, 
Minimum 0.9mm 
UL94 UL 
Insulation tape  Jingjiang Yahua 
Pressure 
Sensitive Glue 
Co., Ltd. 
CT-280 
130
°C 
UL510 UL 
-Alt. use- 
Switching  
Transformer  
/ T5311-1 
Shenzhen 
Haixinxing 
Electronics Co., 
Ltd. 
BCK-03EC28 
Open, concentric 
winding  
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375HF 
Phenolic, V-0, 
Minimum 0.9mm 
UL94 UL 
Insulation tape  Jingjiang Yahua 
Pressure 
Sensitive Glue 
Co., Ltd. 
CT 
130
°C 
UL510 UL 
-Alt. use-  Jingjiang Fuwei 
Adhesive 
Product Co., Ltd. 
FW 
130
°C 
UL510 UL 
Line filter 
/ LIF501  
Huizhou 
Jingquanli 
Electronics Co., 
Ltd. 
JLF-1957-UU10.5 Minimum 
14.3mH IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375J Phenolic, 
V-0 
UL94 
UL 
-Alt. use- 
Page 31 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Object / part 
No. 
Manufacturer/ 
trademark 
Type / model 
Technical data 
Standard 
Mark(s) of 
conformity
1)
Line filter 
/ LIF501 
Shenzhen 
Haixinxing 
Electronics Co., 
Ltd. 
UU10.5 Minimum 
14.3mH 
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375HF Phenolic, 
V-0 
UL94 
UL 
-Alt. use- 
Line filter 
/ LIF501 
Huizhou 
Sunshine 
Electronics Co., 
Ltd. 
UU10.5 Minimum 
14.3mH 
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375HF Phenolic, 
V-0 
UL94 
UL 
AC inlet 
Zhejiang LECI 
Electronics Co., 
Ltd 
DB-8 
250Vac, 2.5A. 
Standard sheet C8 
IEC60320-1, 
EN60320-1, 
GB17465.1 
VDE, 
-Alt. use-  Zhe Jiang Bei Er 
Jia 
ST-A03-002 
250Vac, 2.5A. 
Standard sheet C8 
IEC60320-1, 
EN60320-1, 
VDE 
-Alt. use-  Tecx-Unions 
Technology 
SO-222 
250Vac, 2.5A. 
Standard sheet C8 
IEC60320-1, 
EN60320-1 
VDE 
Primary Fuse-
link 
/ F501 
Shenzhen 
Lanson 
Electronics 
Co., Ltd. 
SMT T3.15A, 
250V 
IEC60127-1, 
IEC60127-3 
VDE  
-Alt. use-  Hollyland Co. 
Ltd. 
5ET T3.15A, 
250V 
IEC60127-1, 
IEC60127-3 
VDE  
Across the line  
Capacitor 
/ CX501 
Xiamen 
Faratronic Co., 
Ltd. 
MKP62 
275Vac, 0.33µF, 
X2 
IEC60384-14, 
EN132400 
VDE 
-Alt. use-  Europtronic 
(Taiwan) Ind. 
Corp. 
MPX 
275Vac, 0.33µF, 
X2 
IEC60384-14, 
EN60384-14 
VDE 
-Alt. use-  Shenzhen 
Jinghao 
Capacitor Co, 
Ltd. 
CBB62B 
280Vac, 0.33µF, 
X2 
IEC60384-14, 
EN60384-14 
VDE 
Line to chassis 
Capacitor 
/ CY501, CY502 
Yinan Don’s 
Electronic 
Component Co., 
Ltd. 
CT81 
Y1, 250V, 470pF 
IEC60384-14, 
EN60384-14 
VDE  
-Alt. use-  TDK-EPC 
Corporation, 
Capacitors 
Group Circuit 
Devices 
Business Group 
CD 
Y1, 250V, 470pF 
IEC60384-14, 
EN60384-14 
VDE  
Page 32 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Object / part 
No. 
Manufacturer/ 
trademark 
Type / model 
Technical data 
Standard 
Mark(s) of 
conformity
1)
-Alt. use-  TDK Corporation 
Module & 
Devices Division 
CD 
Y1, 250V, 470pF 
IEC60384-14, 
EN60384-14 
VDE  
Line to 
Secondary 
Capacitor 
/ CY506 
Yinan Don’s 
Electronic 
Component Co., 
Ltd. 
CT81 
Y1, 250V, 1000pF IEC60384-14, 
EN60384-14 
VDE  
-Alt. use-  TDK-EPC 
Corporation, 
Capacitors 
Group Circuit 
Devices 
Business Group 
CD 
Y1, 250V, 1000pF IEC60384-14, 
EN60384-14 
VDE  
-Alt. use-  TDK Corporation 
Module & 
Devices Division 
CD 
Y1, 250V, 1000pF IEC60384-14, 
EN60384-14 
VDE  
Opto-Coupler 
/ U532 
Sharp 
Corporation 
PC123 
Int/ext creepage: 
>5.0/>8.0mm dti: 
0.7mm 
EN60065 
EN60950-1 
NEMKO 
-Alt. use-  Bright Led 
Electronics Corp. 
BPC-817M 
Int/ext creepage: 
7.6/7.6mm 
dti: 0.4mm 
EN60065 
EN60950-1 
NEMKO 
-Alt. use-  Renesas 
Electronics 
Corporation  
PS2561AL1-1, 
PS2561DL1-1 
Int/ext creepage: 
>4.0/>7.0mm 
dti: 0.4mm 
EN60065 
EN60950-1 
SEMKO 
-Alt. use-  Lite-on 
Technology 
Corporation 
LTV-817 
Int/ext creepage: 
7.8/7.8mm 
dti: 0.6mm 
IEC61051-1 
IEC61051-2 
IEC61051-2-2
FIMKO 
Varistor 
/ RV501 
Thinking 
Electronic 
Industrial Co., 
Ltd. 
TVR14561 Minimum 
395V 
IEC61051-1 
IEC61051-2 
IEC61051-2-2
VDE 
-Alt. use-  Centra Science 
Corp. 
CNR-14D561K Minimum 
395V IEC61051-1 
IEC61051-2 
IEC61051-2-2
VDE 
-Alt. use-  Brightking Inc 
561KD14 
Minimum 395V 
IEC61051-1 
IEC61051-2 
IEC61051-2-2
VDE  
Primary 
Connector 
/ CN501 
Kingfa SCI & 
Tech Co., Ltd. 
PA66-ROW V-0 
UL1977 UL 
-Alt. use-  Shanghai 
Yueshen 
Electronic Co., 
Ltd. 
YSF5 Minimum 
V-1 
UL1977 
UL 
-Alt. use-  Zhe Jiang Deli 
Connectors Co., 
Ltd. 
VH-3A Minimum 
V-1 
UL1977 
UL 
Page of 78
Display

Click on the first or last page to see other SB 200 (serv.man3) service manuals if exist.