Page 21 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
There is no part exceeding 
4kV. 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure 
See appended table of CL.14 
All PCB: V-1 minimum. 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
See appended table of CL.14 
All PCB: V-1 minimum. 
Pass 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
See appended table of CL.14, 
T5311-1, LIF501, primary 
connector. 
Pass 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 Potential 
ignition 
sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
There is no part exceeding 
4kV. 
N/A 
20.2.2 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 N/A 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
A.5 Marking 
and 
instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
Page 22 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Complies with IEC 62151 clause 1  
 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 N/A 
 
Complies with IEC 62151 clause 6 
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
 N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
 N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 N/A 
 
Page 23 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
7.1 
TABLE: temperature rise measurements:  
Pass 
 
Power consumption in the OFF/Stand-by mode of 
the functional switch (W) .........................................: 
0.50 
 
 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Pout (W) 
R/L Speak 
R/L Subwoofer 
Operating Condition / 
Status 
1 90  50  0.267 
12.58 
2.48/2.48, 
0.95/0.95 
2 90  60  0.267 
12.58 
2.48/2.48, 
0.95/0.95 
3 100  50  0.251 
12.45 
2.48/2.48, 
0.95/0.95 
4 100  60  0.251 
12.45 
2.48/2.48, 
0.95/0.95 
5 240  50  0.115 
12.66 
2.48/2.48, 
0.95/0.95 
6 240  60  0.115 
12.66 
2.48/2.48, 
0.95/0.95 
7 264  50  0.110 
12.77 
2.48/2.48, 
0.95/0.95 
8 264  60  0.110 
12.77 
2.48/2.48, 
0.95/0.95 
Input 1 kHz + 8 kHz 
sine wave signal from 
AUX port. 
 
 
Loudspeaker impedance (Ω) ..................................: 
4Ω for each. 
— 
 Several 
loudspeaker systems .................................: 
Right Speak, Left Speak, Right 
Subwoofer, Left Subwoofer.
— 
 
Marking of loudspeaker terminals ...........................: 
-- — 
 
Temperature Rise dT of Part 
dT (K) 
Limit max dT (K) 
Test Condition  
No. 1 
No. 7 
moderate
tropical
01. AC Inlet 
6.0 
5.9 
35 
25 
02. Switch Body 
10.3 
10.3 
50 
40 
03. Primary Wiring near CN501 
9.0 
9.0 
60 
50 
04. Primary Connector Body, CN501 
12.2 
13.0 
35 
25 
05. RV501 Body 
13.6 
12.4 
50 
40 
06. Line Filter LIF501 Coil 
17.8 
21.4 
85 
75 
07. BD1 LC 
16.7 
11.4 
85 
75 
08. CE502 Body 
12.6 
12.1 
70 
60 
09. U531 Body 
19.5 
23.9 
85 
75 
10. Heat Sink Body Attached on U531 
12.2 
10.3 
85 
75 
11. T5311-1 Core 
20.9 
22.7 
-- 
-- 
12. T5311-1 Coil 
22.6 
24.7 
65 
55 
13. D538 LC 
20.4 
21.7 
85 
75 
Page 24 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14. CE533 Body 
15.0 
16.5 
70 
60 
15. PCB near U713 
25.2 
25.2 
85 
75 
16. PCB near U715 
22.4 
22.4 
85 
75 
17. Heat Sink Body Attached on U713 & U715
23.5 
23.5 
85 
75 
18. Front Plastic Enclosure, Inside near 
T5311-1 
5.5 5.6 
44* 
34* 
19. Button (Outside near T5311-1) 
4.4 
4.4 
50 
40 
20. Top Plastic Enclosure, Inside near T5311-
9.8 11.4 
44* 
34* 
21. Top Plastic Enclosure, Outside near 
T5311-1 
4.2  
4.6  
60 
50 
22. Rear Plastic Enclosure, Inside near 
T5311-1 
8.7  
9.0  
44* 
34* 
23. Rear Plastic Enclosure, Outside near 
T5311-1 
6.3  
6.4  
60 
50 
*: Determined by the method specified in Note f to Table 3 of IEC 60065. 
Winding temperature rise measurements 
Ambient temperature T1 (
o
C) ...................... : -- 
-- 
— 
Ambient temperature T2 (
o
C) ...................... : 
25.2 25.6 
— 
 
Temperature rise dT of winding: 
dT = (R
– R
1
) x (234.5 + t1) – (t2 – t1) 
             R
1
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit max (K)  Insulation class
All windings were measured by thermo-
couple. 
-- -- --  -- 
-- 
 
8.8 and 
8.9 
TABLE: distance through insulation measurements 
Pass 
 
Part 
Up 
(peak V)
U r.m.s. 
(V) 
test 
voltage 
(peak V) 
required 
di  (mm)
Di (mm)/
layers 
Transformer, bobbin, as reinforced insulation 
444 
maximum
223 
maximum
4240 0.4 0.90 
Transformer, insulation tape, as reinforced 
insulation 
444 
maximum
223 
maximum
4240 
(2 layer) 
2 layers
0.05 x 3 
layers
Note:  
Transformer bobbin - Chang Chun Plastics Co., Ltd, type T375J, T375HF. 
Transformer insulation tape - Jingjiang Yahua Pressure Sensitive Glue Co. Ltd., type CT or type WF 
/Jingjiang Fuwei Adhesive Product Co., Ltd. Type FW. 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
2.6 
Page of 78