JBL SB 200 (serv.man3) EMC - CB Certificate ▷ View online
Page 21 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
There is no part exceeding
4kV.
4kV.
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
See appended table of CL.14
All PCB: V-1 minimum.
All PCB: V-1 minimum.
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
See appended table of CL.14
All PCB: V-1 minimum.
All PCB: V-1 minimum.
Pass
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
See appended table of CL.14,
T5311-1, LIF501, primary
connector.
T5311-1, LIF501, primary
connector.
Pass
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1 Potential
ignition
sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
There is no part exceeding
4kV.
4kV.
N/A
20.2.2
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
-
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
-
Page 22 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
-
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 23 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
7.1
TABLE: temperature rise measurements:
Pass
Power consumption in the OFF/Stand-by mode of
the functional switch (W) .........................................:
the functional switch (W) .........................................:
0.50
Cond.
Un (V)
Hz
In (A)
Pn (W)
Pout (W)
R/L Speak
R/L Subwoofer
Operating Condition /
Status
Status
1 90 50 0.267
12.58
2.48/2.48,
0.95/0.95
2 90 60 0.267
12.58
2.48/2.48,
0.95/0.95
3 100 50 0.251
12.45
2.48/2.48,
0.95/0.95
4 100 60 0.251
12.45
2.48/2.48,
0.95/0.95
5 240 50 0.115
12.66
2.48/2.48,
0.95/0.95
6 240 60 0.115
12.66
2.48/2.48,
0.95/0.95
7 264 50 0.110
12.77
2.48/2.48,
0.95/0.95
8 264 60 0.110
12.77
2.48/2.48,
0.95/0.95
Input 1 kHz + 8 kHz
sine wave signal from
AUX port.
sine wave signal from
AUX port.
Loudspeaker impedance (Ω) ..................................:
4Ω for each.
—
Several
loudspeaker systems .................................:
Right Speak, Left Speak, Right
Subwoofer, Left Subwoofer.
—
Marking of loudspeaker terminals ...........................:
-- —
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition
No. 1
No. 7
moderate
tropical
01. AC Inlet
6.0
5.9
35
25
02. Switch Body
10.3
10.3
50
40
03. Primary Wiring near CN501
9.0
9.0
60
50
04. Primary Connector Body, CN501
12.2
13.0
35
25
05. RV501 Body
13.6
12.4
50
40
06. Line Filter LIF501 Coil
17.8
21.4
85
75
07. BD1 LC
16.7
11.4
85
75
08. CE502 Body
12.6
12.1
70
60
09. U531 Body
19.5
23.9
85
75
10. Heat Sink Body Attached on U531
12.2
10.3
85
75
11. T5311-1 Core
20.9
22.7
--
--
12. T5311-1 Coil
22.6
24.7
65
55
13. D538 LC
20.4
21.7
85
75
Page 24 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14. CE533 Body
15.0
16.5
70
60
15. PCB near U713
25.2
25.2
85
75
16. PCB near U715
22.4
22.4
85
75
17. Heat Sink Body Attached on U713 & U715
23.5
23.5
85
75
18. Front Plastic Enclosure, Inside near
T5311-1
T5311-1
5.5 5.6
44*
34*
19. Button (Outside near T5311-1)
4.4
4.4
50
40
20. Top Plastic Enclosure, Inside near T5311-
1
1
9.8 11.4
44*
34*
21. Top Plastic Enclosure, Outside near
T5311-1
T5311-1
4.2
4.6
60
50
22. Rear Plastic Enclosure, Inside near
T5311-1
T5311-1
8.7
9.0
44*
34*
23. Rear Plastic Enclosure, Outside near
T5311-1
T5311-1
6.3
6.4
60
50
*: Determined by the method specified in Note f to Table 3 of IEC 60065.
Winding temperature rise measurements
Winding temperature rise measurements
Ambient temperature T1 (
o
C) ...................... : --
--
—
Ambient temperature T2 (
o
C) ...................... :
25.2 25.6
—
Temperature rise dT of winding:
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit max (K) Insulation class
All windings were measured by thermo-
couple.
couple.
-- -- -- --
--
8.8 and
8.9
8.9
TABLE: distance through insulation measurements
Pass
Part
Up
(peak V)
U r.m.s.
(V)
test
voltage
(peak V)
required
di (mm)
Di (mm)/
layers
Transformer, bobbin, as reinforced insulation
444
maximum
223
maximum
4240 0.4 0.90
Transformer, insulation tape, as reinforced
insulation
insulation
444
maximum
223
maximum
4240
(2 layer)
2 layers
0.05 x 3
layers
Note:
Transformer bobbin - Chang Chun Plastics Co., Ltd, type T375J, T375HF.
Transformer insulation tape - Jingjiang Yahua Pressure Sensitive Glue Co. Ltd., type CT or type WF
/Jingjiang Fuwei Adhesive Product Co., Ltd. Type FW.
Transformer bobbin - Chang Chun Plastics Co., Ltd, type T375J, T375HF.
Transformer insulation tape - Jingjiang Yahua Pressure Sensitive Glue Co. Ltd., type CT or type WF
/Jingjiang Fuwei Adhesive Product Co., Ltd. Type FW.
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>
2.6
2
Click on the first or last page to see other SB 200 (serv.man3) service manuals if exist.