JBL SB 200 (serv.man3) EMC - CB Certificate ▷ View online
Page 13 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
-
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
No such resistors.
N/A
Resistors
separately approved ...............................:
N/A
14.2
Capacitors and RC units
See appended table of CL.14.
Pass
Capacitors separately approved :
See appended table of CL.14.
Pass
14.2.1
Y capacitors tested to IEC 60384-14:2005 .............:
CY501, CY502, CY506: Y1.
Pass
14.2.2
X capacitors tested to IEC 60384-14:2005 .............:
CX501: X2.
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 .......................:
connected to the mains: tests for X2 .......................:
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ..................:
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ..................:
No such capacitors.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................:
metal ........................................................................:
N/A
14.3
Inductors and windings
See appended table of CL.14.
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
See CL.20.1.4.
Pass
Page 14 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
manufacturer's name and type ...............................:
T5311-1,
Manufacturer Trademark:
Manufacturer Trademark:
Type: BCK-EC28-W-5633
-Alt. use-
Manufacturer Trademark:
-Alt. use-
Manufacturer Trademark:
Type: BCK- AJ140
-Alt. use-
Manufacturer Trademark:
-Alt. use-
Manufacturer Trademark:
Type: BCK-03EC28.
Pass
Transformers and inductors separately approved .:
No.
N/A
14.3.2
General
T5311-1: Isolating transformer.
Pass
Insulation material complies with clause 20.1.4
See appended table of CL.14.
Pass
14.3.3
Constructional requirements
See appended table of CL.14.
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See appended table of CL.13.
Pass
14.3.3.2
Transformers meet the constructional requirements See appended table of CL.13.
Pass
14.3.4
Separation between windings
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
See appended table of CL.13.
Pass
Coil formers and partition walls > 0,4 mm
See appended table of CL.8.8
and 8.9.
and 8.9.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
Pass
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See CL.14.3.3.2 and
appended table of CL.8.8 and
8.9.
appended table of CL.8.8 and
8.9.
Pass
Coil formers and partition walls > 0,4 mm
See CL.14.3.4.1.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
Page 15 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.4
High voltage components
Not provided.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
See appended table of CL.14,
Primary Fuse: F501.
Primary Fuse: F501.
Pass
Protective devices used within their ratings
See appended table of CL.13.
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
See appended table of CL.13.
Pass
14.5.1.1
a) Thermal cut-outs separately approved
Not provided.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Not provided.
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
Not provided.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
See appended table of CL.14.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ...:
F501: T3.15AL250V.
Pass
14.5.2.3
Not possible to connect fuses in parallel ................:
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
Not possible to replace the
fuse without a tool.
fuse without a tool.
Pass
14.5.3
PTC thermistors comply with IEC 60730-1:2007
Not provided.
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
See appended table of CL.14.
Pass
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Certified power switch
provided, complies with the
requirements and
characteristics.
(See appended table 14)
provided, complies with the
requirements and
characteristics.
(See appended table 14)
Pass
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Page 16 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
Not provided.
N/A
Safety interlocks to 2.8 of IEC 60950-1
N/A
14.8
Voltage setting devices and the like
Not provided.
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
Not
provided.
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N/A
14.10
Batteries
Provided within Remote
Control.
Control.
Pass
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
Pass
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
See appended table of CL.14.
Pass
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A