Page 13 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 N/A 
 
14 Components 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such resistors. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
No such resistors. 
N/A 
 Resistors 
separately approved ...............................: 
 
N/A 
14.2 
Capacitors and RC units  
See appended table of CL.14.
Pass 
 
Capacitors separately approved  : 
See appended table of CL.14.
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14:2005 .............:
CY501, CY502, CY506: Y1. 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14:2005 .............:
CX501: X2. 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 .......................:
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better ..................:
No such capacitors. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................: 
 N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ........................................................................: 
 N/A 
14.3 
Inductors and windings  
See appended table of CL.14.
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
See CL.20.1.4. 
Pass 
Page 14 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
T5311-1, 
 
Manufacturer Trademark: 
  
Type: BCK-EC28-W-5633 
-Alt. use- 
Manufacturer Trademark:  
 
Type: BCK- AJ140 
-Alt. use- 
Manufacturer Trademark: 
 
Type: BCK-03EC28. 
Pass 
 
Transformers and inductors separately approved .: 
No. 
N/A 
14.3.2 
General  
T5311-1: Isolating transformer.
Pass 
 
Insulation material complies with clause 20.1.4  
See appended table of CL.14.
Pass 
14.3.3 
Constructional requirements  
See appended table of CL.14. 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
See appended table of CL.13.
Pass 
14.3.3.2 
Transformers meet the constructional requirements  See appended table of CL.13.
Pass 
14.3.4 
Separation between windings 
 
Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)..............................: 
See appended table of CL.13.
Pass 
 
Coil formers and partition walls > 0,4 mm  
See appended table of CL.8.8 
and 8.9. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
 N/A 
14.3.4.3 
Separating transformers with at least basic insulation  
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 Pass 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
See CL.14.3.3.2 and 
appended table of CL.8.8 and 
8.9. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
See CL.14.3.4.1. 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 N/A 
Page 15 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.4 
High voltage components  
Not provided. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 N/A 
14.5 
Protective devices  
See appended table of CL.14, 
Primary Fuse: F501. 
Pass 
 
Protective devices used within their ratings  
See appended table of CL.13.
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
See appended table of CL.13.
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved  
Not provided. 
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
Not provided. 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
Not provided. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
See appended table of CL.14.
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...: 
F501: T3.15AL250V. 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ................: 
 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
Not possible to replace the 
fuse without a tool. 
Pass 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
Not provided. 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
 N/A 
14.6 
Switches  
See appended table of CL.14.
Pass 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Certified power switch 
provided, complies with the 
requirements and 
characteristics.  
(See appended table 14) 
Pass 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
Page 16 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Switch controlling < 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
Not provided. 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
Not provided. 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 N/A 
14.9 Motors 
Not 
provided. 
N/A 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 N/A 
14.10 
Batteries 
Provided within Remote 
Control. 
Pass 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 Pass 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
See appended table of CL.14.
Pass 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
Page of 78