DOWNLOAD JBL SB 200 (serv.man3) Service Manual ↓ Size: 1.85 MB | Pages: 78 in PDF or view online for FREE

Model
SB 200 (serv.man3)
Pages
78
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-200-sm3.pdf
Date

JBL SB 200 (serv.man3) EMC - CB Certificate ▷ View online

 
 
 
 
 
 
 
Test Report issued under the responsibility of:  
 
TEST REPORT 
IEC 60065 
Audio, video and similar electronic apparatus - Safety requirements 
 
 
 
Report Number. ..............................: 
350-120155AX 
Date of issue ...................................: 
2012-09-04 
Total number of pages...................: 
70 pages 
 
Applicant’s name............................:  
Harman International Industries, Inc. 
Address ...........................................:  8500 Balboa Blvd, Northridge, CA 91329, United States of America
Test specification: 
 
Standard ..........................................:  IEC 60065: 2001 (Seventh Edition) + A1: 2005 + A2: 2010  
(including tropical condition: clause 7.1, 10.2, 10.3, 11) 
EN 60065: 2002 (Seventh Edition) + A1: 2006  + A11: 2008 + A2: 
2010 + A12: 2011 
Test procedure................................:  CB Scheme 
Non-standard test method.............:  N/A 
Test Report Form No......................:  IEC60065K 
Test Report Form(s) Originator.....:  Intertek Semko AB 
Master TRF ......................................:  Dated 2010-10 
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as 
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from 
the reader's interpretation of the reproduced material due to its placement and context
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB 
Scheme procedure shall be removed. 
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and 
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
 
Test item description .....................: Soundbar 
Trade Mark ......................................:
 
Manufacturer...................................: Harman International Industries, Inc. 
Model/Type reference ....................: CINEMA SB200, CINEMA STV200 
Ratings ............................................: 100-240V~, 50/60Hz. 60W, Class II 
 
 
Page 2 of 70 
Report No.: 350-120155AX
 
 
TRF No. IEC60065K 
Testing procedure and testing location: 
 CB 
Testing 
Laboratory: 
Audix Technology (Shanghai) Co., Ltd. 
Testing location/ address ........................:
3-4F 34 Bldg. 680 Guiping Rd., Caohejing Hi-Tech Park 
Shanghai CHINA 
 
Tested by (name + signature) ....... :  Mark Han 
 
 
Approved by (name + signature).. :  Kuma Kao 
 
  Associated CB Laboratory: 
 
Testing location/ address ........................:
 
 
 
Tested by (name + signature) ....... : 
 
 
 
Approved by (name + signature).. : 
 
 
  Testing procedure: TMP 
 
Testing location/ address ........................:
 
 
 
Tested by (name + signature) ....... : 
 
 
 
Approved by (name + signature).. : 
 
 
  Testing procedure: WMT 
 
Testing location/ address ........................:
 
 
 
Tested by (name + signature) ....... : 
 
 
 
Witnessed by (name + signature). : 
 
 
 
Approved by (name + signature).. : 
 
 
  Testing procedure: SMT 
 
Testing location/ address ........................:
 
 
 
Tested by (name + signature) ....... : 
 
 
 
Approved by (name + signature).. : 
 
 
 
Supervised by (name + signature) : 
 
 
  Testing procedure: RMT 
 
Testing location/ address ........................:
 
 
 
Tested by (name + signature) ....... : 
 
 
 
Approved by (name + signature).. : 
 
 
 
Supervised by (name + signature) : 
 
 
 
Page 3 of 70 
Report No.: 350-120155AX
 
 
TRF No. IEC60065K 
 
List of Attachments (including a total number of pages in each attachment):  
 
Manufacturer’s Declaration: 1 sheet 
 
Photograph: 7 sheet(s) / 14 Fig(s). 
Summary of testing:  
1.  The sample tested complies with the requirements of the test specification. 
 
2.  Model CINEMA STV200 is identical to model CINEMA SB200 except for model designation and market. 
Unless otherwise specified, all tests were performed on model CINEMA SB200. 
 
3.  The subject model as above is a Cinema Powered Soundbar Speaker Based on applicant’s testing 
instruction and all requirements were tested on an open bench. 
 
4.  Power Transformers (T5311-1) were made by these factories, Jingquanli / Sunshine / Haixinxing, there 
are the same winding specifications and electrical characteristics. Accordingly all tests were conducted 
on as follows. 
 
Haixinxing / BCK-03EC28. 
 
5.  Following symbols and abbreviations are used in this test report. 
S/C= Short-Circuit 
O/C= Open-Circuit 
O/L= Overload 
MT= Mains Transformer  TW= Transformer Winding (measured by resistance method) 
TC= Transformer Core 
TP= Thermal Protector 
NH= No Hazard Occurred  NFR= No Further Results existed 
TRSR = Test Repeated Similar Results as just before the test 
NCH= No component Heated higher than Heating under normal operating condition, CL. 7. 
NCD= No component Damaged.  
CD (X)= Component Damaged. (X: damage component ID indicated)  
CH (X)= Component Heated (X: heated component ID indicated) and thermally stabilized. 
+ = total overheated areas of the printed board(s) are not larger than 2 cm². 
LC= Lead Connection on the printed board 
PCB= Printed Circuit Board 
IE= Inside of Enclosure 
OE= Outside of Enclosure 
KH= Knob, Handle 
PW= Primary Wire 
IB=Insulating Barrier 
E = Emitter 
C = Collector 
B = Base 
* = Determined by the method specified in Note f to Table 3. 
 
Tests performed (name of test and test clause): 
 
Full tests. 
Testing location: 
See CB Testing Laboratory information.  
Summary of compliance with National Differences 
List of countries addressed: 
EN, AU, NZ, KR, MY, UA, JP 
 
SG, KE, BR, RU (no national differences in CB-Bulletin) 
Page 4 of 70 
Report No.: 350-120155AX
 
 
TRF No. IEC60065K 
Copy of marking plate:  
The artwork below may be only a draft. The use of certification marks on a product must be 
authorized by the respective NCBs that own these marks. 
 
Test item particulars .................................................. : 
See general product information for the details. 
Classification of installation and use ...................... : 
Table-Top or Wall-Mounting, Not portable, Not 
intend to use for floor standing. 
Supply Connection .................................................... : 
Detachable Power Supply Cord 
Possible test case verdicts: 
 
- test case does not apply to the test object .......... : 
N/A (Not Applicable) 
- test object does meet the requirement ................. : 
Pass 
- test object does not meet the requirement .......... : 
Fail 
Testing: 
 
Date of receipt of test item........................................ : 
2012-07-09 
Date (s) of performance of tests .............................. : 
2012-07-09 to 2012-07-25 
Page of 78
Display

JBL SB 200 (serv.man3) EMC - CB Certificate ▷ Download

  • DOWNLOAD JBL SB 200 (serv.man3) Service Manual ↓ Size: 1.85 MB | Pages: 78 in PDF or view online for FREE
  • Here you can View online or download the EMC - CB Certificate for the JBL SB 200 (serv.man3) in PDF for free, which will help you to disassemble, recover, fix and repair JBL SB 200 (serv.man3) Audio. Information contained in JBL SB 200 (serv.man3) EMC - CB Certificate (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.