JBL ON TIME MICRO (serv.man2) EMC - CB Certificate ▷ View online
- Page 9 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
N
8.11
Detaching of wires
N
No undue reduction of creepage or clearance
distances if wires become detached
distances if wires become detached
N
Vibration
test carried out ........................................ :
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (pull test 50 N, for
10 s)
10 s)
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
N
8.16
Only special supply equipment can be used
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
8.19.1 Disconnection
device
N
All-pole switch or circuit breaker with > 3mm
contact separation
contact separation
N
8.19.2
Mains switch ON indication
N
8.20
Switch not fitted in the mains cord
N
8.21
Bridging components comply with clause 14
N
- Page 10 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
(The approved Class II switching power supply be used)
P
9.1
Testing on the outside
N
9.1.1
For voltage > 1000 V ac or > 1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage.
N
9.1.1.1
Touch current measured from terminal devices
using the network in Annex D ................................ :
using the network in Annex D ................................ :
N
Discharge not exceeding 45
μC
N
Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
N
9.1.2
No hazardous live shafts of knobs, handlers or
levers
levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe 16 of IEC 61 032
pin (10 N); test probe 16 of IEC 61 032
N
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61 032
straight wire (1 N); test probe D of IEC 61 032
N
9.1.5
Pre-set controls tested with 2 mm x 100 mm test
pin (10 N); test probe C of IEC 61 032
pin (10 N); test probe C of IEC 61 032
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N
If C is not greater than 0,1
μF no test needed
N
9.1.7
Enclosure sufficiently resistant to external force
N
Test probe 11 of IEC 61 032 for 10 s (50 N)
N
Test hook of fig. 4 for 10 s (20 N)
N
30 mm diameter test tool for 5 s (100 or 250 N) .... :
N
9.2
No hazard after removing a cover by hand
N
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (M
Ω) at least 2 MΩ min. after
surge test for basic and 4 M
Ω min. for reinforced
insulation
:
The approved Class II
switching power supply be
used.
switching power supply be
used.
P
10.2
Humidity treatment 48 h or 120 h :
At 93% R.H., 48h, 30
°C.
P
- Page 11 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
10.3
Insulation resistance and dielectric strength
(see appended table).
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault conditions
No electric shock during fault
operation. For details refer to
appended table 11.2.
P
11.2
Heating under fault condition
See below.
P
Flames extinguish within 10 seconds
No such flames
P
No hazard from softening solder
No solder point became soft.
P
Soldered terminations not used as protective
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table).
P
11.2.2
Temperature rise of accessible parts
(see appended table).
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table).
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
No such parts. See 7.1.3.
P
11.2.5
Temperature rise of windings
(See appended table)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
P
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
N
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N
- Page 12 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
12
MECHANICAL STRENGTH ( The approved Class II switching power supply
be used.)
be used.)
P
12.1.1
Bump test where mass > 7kg
<7kg
N
12.1.2 Vibration
test
N
12.1.3
Impact hammer test
N
Steel ball test
N
12.1.4
Drop test for portable apparatus where mass < 7kg
N
12.1.5
Thermoplastic enclosure strain relief test
N
12.2
Fixing of knobs, push buttons, keys and levers
N
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
N
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
PARTS CONNECTED TO THE SUPPLY MAINS
(The approved Class II switching power supply be used.)
P
13.1
Clearances in accordance with 13.3
N
Creepage distances in accordance with 13.4
N
13.2
Determination of operating voltage
N
13.3 Clearance
N
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
N
13.3.3
Circuit not conductively connected to the mains
comply with table 10
comply with table 10
N
13.4 Creepage
distances
N
Creepage distances greater than table 11 minima
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.