- Page 9 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
 
8.11 
Detaching of wires 
 
 
No undue reduction of creepage or clearance 
distances if wires become detached 
 
 Vibration 
test carried out  ........................................ :  
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 
8.14 
Adequate fastening of covers (pull test 50 N, for 
10 s) 
 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 
8.16 
Only special supply equipment can be used 
 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 
8.18 
Endurance test as required by 8.17 
 
8.19 
Disconnection from the mains 
The approved Class II 
switching power supply be 
used. 
8.19.1 Disconnection 
device 
 
 
All-pole switch or circuit breaker with > 3mm 
contact separation  
 
8.19.2 
Mains switch ON indication 
 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
 
N
 
 
 
- Page 10 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
(The approved Class II switching power supply be used) 
9.1 
Testing on the outside 
9.1.1 
For voltage > 1000 V ac or > 1500 V dc complies 
with clause 13.3.1 for basic insulation 
No such high voltage. 
9.1.1.1 
Touch current measured from terminal devices 
using the network in Annex D  ................................ :
  
 
Discharge not exceeding 45 
μC 
 N 
 
Energy of discharge not exceeding 350 mJ 
 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handlers or 
levers 
 N 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe 16 of IEC 61 032 
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61 032 
 
9.1.5 
Pre-set controls tested with 2 mm x 100 mm test 
pin (10 N); test probe C of IEC 61 032 
 N 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
 N 
 
If C is not greater than 0,1 
μF no test needed 
 N 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61 032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... :  
9.2 
No hazard after removing a cover by hand 
 
 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (M
Ω) at least 2 MΩ min. after 
surge test for basic and 4 M
Ω min. for reinforced 
insulation  
The approved Class II 
switching power supply be 
used.
 
10.2 
Humidity treatment 48 h or 120 h  : 
At 93% R.H., 48h, 30
°C. 
 
- Page 11 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
10.3 
Insulation resistance and dielectric strength 
(see appended table). 
 
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I) 
The approved Class II 
switching power supply be 
used.
 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
The approved Class II 
switching power supply be 
used.
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault conditions 
No electric shock during fault 
operation. For details refer to 
appended table 11.2. 
11.2 
Heating under fault condition 
See below. 
 
Flames extinguish within 10 seconds
 
No such flames 
 
No hazard from softening solder 
No solder point became soft. 
 
Soldered terminations not used as protective 
mechanism 
 
11.2.1 
Measurement of temperature rises 
(see appended table). 
11.2.2 
Temperature rise of accessible parts 
(see appended table). 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table). 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
No such parts. See 7.1.3. 
11.2.5 
Temperature rise of windings 
(See appended table) 
P 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5 
 P 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 P 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm² ................ :
 N 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min
 N 
 
- Page 12 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted
 
 N 
 
Class I protective earthing maintained
 
The approved Class II 
switching power supply be 
used. 
 
 
12 
MECHANICAL STRENGTH           ( The approved Class II switching power supply 
be used.) 
12.1.1 
Bump test where mass > 7kg 
<7kg 
12.1.2 Vibration 
test 
 
12.1.3 
Impact hammer test 
 
 
Steel ball test 
 
12.1.4 
Drop test for portable apparatus where mass < 7kg   
12.1.5 
Thermoplastic enclosure strain relief test 
  
12.2 
Fixing of knobs, push buttons, keys and levers 
 
 N 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
12.5 
Antenna coaxial sockets providing isolation 
 
12.6 
Telescoping or rod antennas construction 
 
12.6.1 
Telescoping or rod antennas securement 
 
 
13 
PARTS CONNECTED TO THE SUPPLY MAINS  
(The approved Class II switching power supply be used.) 
13.1 
Clearances in accordance with 13.3 
 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
 
13.3 Clearance 
 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
 N 
13.3.3 
Circuit not conductively connected to the mains 
comply with table 10 
 N 
13.4 Creepage 
distances 
 
 
Creepage distances greater than table 11 minima   
Page of 39