Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11 Optocouplers
N
Optocouplers comply with Cl. 8
N
N
14.12
Surge suppression varistors
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus.
parts except for earthed parts of permanently
connected apparatus.
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
No mains socket outlets
N
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket outlets
N
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
No such connectors.
N
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
P
15.1.3
Output terminals of AC adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
No such output terminal
N
15.2
Provision for protective earthing
N
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
- Page 18 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
output voltage: output circuit not connected to
earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance (
Ω) test: ≤ 0,1 Ω at 25 A .............. : N
15.3
Terminals for external flexible cords and for permanent connection to the mains
supply
supply
N
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2
Reliable connection of non-detachable cords:
N
not soldered to conductors of a printed circuit
board
board
N
adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N
wire secured by additional means to the conductor
N
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
No such screws used.
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by
Table 16
Table 16
See 15.3.3.
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
No such construction.
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
- Page 19 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
No such terminal.
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N
Terminals located and shielded: test with 8 mm
strand
strand
N
15.4
Devices forming a part of the mains plug
N
15.4.1
No undue strain on mains socket-outlets
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
(The approved Class II switching power supply be used.)
N
16.1
Mains cords sheathed type, complying with
IEC 60 227 for PVC or IEC 60 245 for synthetic
rubber cords ............................................................ :
IEC 60 227 for PVC or IEC 60 245 for synthetic
rubber cords ............................................................ :
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
N
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
N
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60 227-2)
withstand bending and mechanical stress (3.2 of
IEC 60 227-2)
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
N
- Page 20 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60 320-1
fitted with detachable cord set with appliance inlet
to IEC 60 320-1
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N
17 ELECTRICAL
CONNECTIONS
AND MECHANICAL FIXINGS
P
17.1
Torque test to Table 20:
P
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N
17.3
Cover fixing screws: captive
See below.
N
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
N
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
No such means.
N
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure by
screws.
screws.
N
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
See 17.1
N
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable legs or stands.
N