JBL ON TIME MICRO (serv.man2) EMC - CB Certificate ▷ View online
- Page 21 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
17.9
N
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
N
Picture tube separately approved to IEC 61965..... :
N
Picture tube separately approved to 18.1
N
18.1
Picture tubes > 16 cm intrinsically protected
No picture tube.
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N
18.3 Non-intrinsically
protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ................. : < 7kg
N
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N
19.1
Test on a plane, inclined at 10
° to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
Apparatus mass > 25kg or height > 1M or supplied
with cart or stand
with cart or stand
N
19.4
Smooth edges and corners
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surfaces.
N
19.6
Wall or ceiling mountings adequate
N
- Page 22 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
20
RESISTANCE TO FIRE ( The approved Class II switching power supply
be used.)
be used.)
P
20.1
Electrical components and mechanical parts
No exception of condition a) or b), it shall comply with the requirements of 20.1.1,
20.1.2, 20.1.3 and 20.1.4.
20.1.2, 20.1.3 and 20.1.4.
N
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60 707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60 707 with
openings not exceeding 1 mm in width
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
b) Exemption for small components as defined in
20.1
20.1
PCB: V-0
N
20.1.1 Electrical
components
meet the requirements of
clause 14 or 20.1.4
N
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60 707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC 60 707, unless used in a fire
enclosure
N
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets F-0 to IEC 60 707
available power exceeds 15 W at a voltage >
400 V (peak) a.c. or d.c. meets F-0 to IEC 60 707
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No such high voltage.
N
20.2.2
No internal fire enclosure.
N
- Page 23 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
Ditto. N
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
The equipment is not intended for outdoor use.
N
A.5
Marking and instructions
IPX0
N
A.5.1
j) Marked with IPX4 (IEC 60 529), 5.4.1 a) does
not apply
not apply
N
A.10.2.1
Enclosure provides protection against splashing
water
water
N
A.10.2.2 Humidity
treatment
carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
No telecommunication connection.
N
Complies with IEC 62151 clause 1
No TNV.
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPIC PURPOSES
APPARATUS FOR PHOTOGRAPIC PURPOSES
N
L5
Marking and Instructions
N
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of
flash apparatus with which it is to be used
apparatus indicating type or model number of
flash apparatus with which it is to be used
N
- Page 24 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N
L. 7
Heating under normal operating conditions
N
L7.1.5 &
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of
IEC 60086-4
IEC 60086-4
N
L. 9
Electric shock hazard under normal operating
conditions
conditions
N
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N
L.10
Insulation requirements
N
L. 10.3.2
High frequency puls ignition
N
L. 12
Mechanical strength
N
L. 12.1.3
Windows for flash tubes are excluded from steel
ball impact test
ball impact test
N
L. 14
Components
N
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N
L. 20
Resistance to fire
N
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.