DOWNLOAD JBL ON TIME MICRO (serv.man2) Service Manual ↓ Size: 1.97 MB | Pages: 39 in PDF or view online for FREE

Model
ON TIME MICRO (serv.man2)
Pages
39
Size
1.97 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-time-micro-sm2.pdf
Date

JBL ON TIME MICRO (serv.man2) EMC - CB Certificate ▷ View online

 
- Page 21 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
17.9 
 N 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION  
 
Picture tube separately approved to IEC 61965..... :  
 
Picture tube separately approved to 18.1 
 
18.1 
Picture tubes > 16 cm intrinsically protected 
No picture tube.
 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 N 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N 
18.3 Non-intrinsically 
protected tubes tested to 18.3 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg  ................. : < 7kg 
 
Apparatus intended to be fastened in place – 
suitable instructions  
 N 
19.1 
Test on a plane, inclined at 10
° to the horizontal 
 N 
19.2 
100 N force applied vertically downwards 
 
19.3 
Apparatus mass > 25kg or height > 1M or supplied 
with cart or stand 
 N 
19.4 
Smooth edges and corners 
 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surfaces. 
19.6 
Wall or ceiling mountings adequate 
 
 
- Page 22 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
 
20 
RESISTANCE TO FIRE                   ( The approved Class II switching power supply 
be used.) 
20.1 
Electrical components and mechanical parts 
No exception of condition a) or b), it shall comply with the requirements of 20.1.1, 
20.1.2, 20.1.3 and 20.1.4.
 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60 707 with 
openings not exceeding 1 mm in width 
The approved Class II 
switching power supply be 
used. 
 
b) Exemption for small components as defined in 
20.1 
 PCB: V-0 
20.1.1 Electrical 
components 
meet the requirements of 
clause 14 or 20.1.4  
 N 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC 60 707, unless used in a fire 
enclosure 
 N 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage > 
400 V (peak) a.c. or d.c. meets F-0 to IEC 60 707 
 N 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
 N 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 N 
20.2 Fire 
enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
No such high voltage.
 
20.2.2 
No internal fire enclosure. 
 
- Page 23 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
Ditto. N 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
The equipment is not intended for outdoor use.
 
A.5 
Marking and instructions
 
IPX0
 
A.5.1 
j) Marked with IPX4 (IEC 60 529), 5.4.1 a) does 
not apply 
 N 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N 
A.10.2.2 Humidity 
treatment 
carried out for 7 days 
 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
No telecommunication connection.
 
 
Complies with IEC 62151 clause 1 
No TNV.
 
 
Complies with IEC 62151 clause 2 
 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 N 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 N 
 
Complies with IEC 62151 clause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 N 
 
Complies with IEC 62151 clause 6 
 
 
Complies with IEC 62151 clause 7 
 
 
Complies with IEC 62151 annex A, B and C 
 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPIC PURPOSES 
L5 
Marking and Instructions 
 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of 
flash apparatus with which it is to be used 
  
 
- Page 24 of 39 - 
 
 
 
Report No. NTEK-2011NT1009318S 
 EN 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NTEK Testing Technology Co., Ltd. 
 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used 
 
L. 7 
Heating under normal operating conditions 
 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of 
IEC 60086-4 
 
L. 9 
Electric shock hazard under normal operating 
conditions 
 
L9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE 
 
L.10
 
Insulation requirements
 
 
L. 10.3.2 
High frequency puls ignition 
 
L. 12 
Mechanical strength 
 
L. 12.1.3 
Windows for flash tubes are excluded from steel 
ball impact test 
 
L. 14 
Components 
 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions 
 
L. 20 
Resistance to fire
 
 
L. 20.1 c)
 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE 
 
 
Page of 39
Display

Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.