JBL ON TIME MICRO (serv.man2) EMC - CB Certificate ▷ View online
- Page 5 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
3 GENERAL
REQUIREMENTS
P
Safety class of the apparatus ................................. : The approved Class II
switching power supply be
used.
used.
P
4
GENERAL CONDITIONS OF TESTS
P
4.1.4 Ventilation
instructions
require the use of the test
box
Yes
P
5 MARKING
P
Comprehensible and easily discernible
All markings are printed on
label pasted on outer
enclosures of the appliance.
label pasted on outer
enclosures of the appliance.
P
Permanent durability against water and petroleum
spirit
spirit
After rubbing test by water and
petroleum spirit, the label still
easily discernible, indelible and
legible.
petroleum spirit, the label still
easily discernible, indelible and
legible.
P
5.1
a) Identification, maker, model ............................... : See the label
P
b) Model number or type reference
jbl on time™ micro
P
c) Class II symbol
...........................................:
Marking on the switching
power supply.
power supply.
P
d) Nature of supply
...........
...........................
:
IEC 60417-5032 symbol used
P
e) Rated supply voltage .......................................... : AM/FM Radio & Speaker Dock
For Ipod/Iphone: DC12V
Switching power supply: 100-
240Vac
240Vac
P
f) Mains frequency if safety dependant ...................:
Switching power supply:
50/60Hz
50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ...........................................................................:
P
Measured current or power consumption ...............:
(See appended table 7.1)
P
Deviation % (max 10%) ...........................................:
(See appended table 7.1)
P
h) Rated current or power consumption for
apparatus intended for connection to an a.c. mains
supply.:
apparatus intended for connection to an a.c. mains
supply.:
N
Measured current or power consumption ...............:
Not Television set.
N
- Page 6 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Measured current or power consumption for
Television set ...........................................................:
Television set ...........................................................:
N
Deviation % (max 10%) ...........................................: N
5.2 Earth
terminal
N
Hazardous live terminals
No terminal devices which are
live under normal operating
conditions.
live under normal operating
conditions.
N
Supply output terminals (other than mains)
No output terminals for supply
purpose.
purpose.
N
5.3
Use of triangle with exclamation mark
The mark is shown on the
electrical diagram above every
safety critical component.
electrical diagram above every
safety critical component.
N
b) marking on loudspeaker grille, IEC 60417-5036
N
5.4
Instructions for use
Instruction and marking in
English.
English.
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
N
Hazardous live terminals, instructions for wiring
No terminals are hazardous
live.
live.
N
Instructions for replacing lithium battery
No batteries used.
N
Instructions for modem if fitted.
N
Class I earth connection warning
N
Instructions for multimedia system connection
In user’s manual.
P
Special stability warning for fixed installation
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and marking
switch location, accessibility and marking
Not directly connected to
mains
N
Instructions for permanently connected equipment The apparatus is not a
permanently connected
apparatus.
apparatus.
N
6 HAZARDOUS
RADIATION
No ionization radiation or laser inside the equipment.
N
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation inside the
EUT.
EUT.
N
- Page 7 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Ionizing radiation under fault condition
N
6.2
Laser radiation, emission limits to IEC 60 825-1 ... :
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table).
P
7.1.1
Temperature rise of accessible parts
(see appended table).
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table).
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table).
P
7.1.4
Temperature rise of windings
(see appended table).
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table).
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
°C
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK (The approved Class II switching power
supply be used)
AGAINST ELECTRIC SHOCK (The approved Class II switching power
supply be used)
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such part.
N
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Approved switching power
supply be used.
supply be used.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used.
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No hand removable cover.
N
8.5
Class I equipment
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N
- Page 8 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
The approved Class II
switching power supply be
used.
switching power supply be
used.
N
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
N
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
N
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N
Separation by Class II isolating transformer
N
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation
≥ 0,4 mm (mm) :
N
Reinforced insulation
≥ 0,4 mm (mm) .................... :
N
Thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.