JBL ON TIME MICRO (serv.man2) EMC - CB Certificate ▷ View online
- Page 13 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
13.5 Printed
boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60 664-3 (basic insulation only)
with IEC 60 664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermitically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in Table 12
not conductively connected to the mains:
clearances and creepage distances as in Table 12
Not such a construction.
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N
14
COMPONENTS (The approved Class II switching power supply
be used.)
be used.)
P
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
N
Capacitors separately approved
N
14.2.1
Y capacitors tested to IEC 384-14, 2nd edition ..... :
N
14.2.2
X capacitors tested to IEC 384-14, 2nd edition ..... :
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC 60 384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC 60 384-1, 4.38 category B or
better ....................................................................... :
N
- Page 14 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
Table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
Table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
N
Shielded by a barrier to FV 0 or metal ................... :
N
14.3
Inductors and windings
N
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
N
Transformers and inductors separately approved . :
N
14.3.2 General
N
14.3.3 Constructional
requirements
N
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
N
14.3.3.2
Transformers meet the constructional
requirements
requirements
N
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls
≥ 0,4 mm
N
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
N
Coil formers and partition walls
≥ 0,4 mm
N
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
- Page 15 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Component meets category FV 1 of IEC 60 707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
N
Protective devices used within their ratings
N
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
N
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60 127
IEC 60 127
N
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
N
14.5.2.3
Not possible to connect fuses in parallel ............... :
N
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
N
14.5.3
PTC-S thermistors comply with IEC 60 730-1
N
PTC-S devices (15 W) category FV 1 or better
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N
14.6 Switches
N
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operation, Nirmal pollution suitability,
Resistance to heat and fire level 3 and V-0
compliance with annex G, G.1.1
Resistance to heat and fire level 3 and V-0
compliance with annex G, G.1.1
N
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact voltage
> 35 V (peak) / 24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak) / 24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N
- Page 16 of 39 -
Report No. NTEK-2011NT1009318S
EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
NTEK Testing Technology Co., Ltd.
Switch controlling > 0.2A with open contact voltage
> 35 V (peak) / 24 V dc complying with 14.6.3 and
V-0 in annex G, G.1.1
> 35 V (peak) / 24 V dc complying with 14.6.3 and
V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact voltage
> 35 V (peak) / 24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak) / 24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in used
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in used
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N
14.6.5
Mains switch controlling mains socket-outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N
Socket-outlet current marking correct
N
14.7
Safety interlocks
N
Safety interlocks to 2.8 of IEC 60 950
N
14.8
Voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9
Motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
Click on the first or last page to see other ON TIME MICRO (serv.man2) service manuals if exist.