- Page 9 of 19 - 
 
 
   
 
Order No.  23171 
 
 
GENERAL  
 
— 
1.1 
SCOPE  
 
— 
1.1.1 
Equipment covered by this 
standard 
The product is driven by a digital audio signal and is 
therefore considered within the scope of IEC 60950.  
— 
1.1.2 
Additional requirements:  
 
— 
 
Exposure to extreme temperatures, 
excessive dust, moisture or 
vibration; to flammable gases; to 
corrosive or explosive atmospheres  
This equipment is intended to operate in a "normal" 
environment (Offices and homes). Max recommended 
ambient temperature (T
MRA
) as stated by the 
manufacturer is 25
°
C. 
— 
 
Electromedical equipment 
connected to the patient  
This equipment is not an electromedical equipment 
intended to be physically connected to a patient. 
— 
 
Equipment used in vehicles, ships 
or aircrafts, in tropical countries, or 
at elevations > 2000m   
This equipment is intended to operate in a "normal" 
environment (Offices and homes). Max recommended 
ambient temperature (T
MRA
) as stated by the  
manufacturer is 25
°
C. 
— 
 
Equipment intended for use where 
ingress of water is possible   
This equipment is intended to be used in applications 
where ingress of water is not regarded possible. The 
equipment is non-protected according to IEC 60529. 
— 
 
IP-classification (IEC 60529) (IP)  
IP X0. 
— 
 
 
1.2.2 
OPERATING CONDITIONS 
 
— 
1.2.2.1 
Normal load as described in Annex 
L or as close as possible to the 
most severe normal use  
Max. undistorted with sign wave signal was 16.1 W, 
reduce d to 1/8
th
 Max. and switched to filtered pink noise 
per IEC/EN 60065 for maximum normal load. 
Refer to Summary of Testing. 
— 
1.2.2.2 
Rated operating time as assigned 
by the manufacturer  
The manufacturer has not declared a rated operating 
time. 
— 
1.2.2.3 
Continuous operation  
The equipment is regarded to be for continuous 
operation. 
— 
 
 
 
 
- Page 10 of 19  - 
 
 
   
 
Order No.  23171 
 
 
1.5  
COMPONENTS 
 
— 
1.5.1 
General 
Refer to List of Critical Components. 
1.5.2 
Evaluation and testing of 
components 
Certified components are used in accordance with their 
ratings, certifications and they comply with applicable 
parts of this standard. 
Components not certified are used in accordance with 
their ratings and they comply with applicable parts of 
IEC 60950 and the relevant component standard. 
Components, for which no relevant IEC-standard exists, 
have been tested under the conditions occurring in the 
equipment, using applicable parts of IEC 60950. 
 
Dimensions of mains plug for direct 
plug-in equipment  
Not intended to plug directly into a wall socket-outlet. 
1.5.3 
Thermal controls  
No adjustable thermal controls. 
1.5.4 
Transformers  
Class III equipment. 
1.5.5 
Interconnecting cables  
The interconnecting cables contain only SELV. 
1.5.6 
Capacitors in primary circuits 
Class III equipment. 
1.5.7.1 
- 1.5.7.3 Double or reinforced 
insulation bridged by components  
Class III equipment. 
1.5.8 
Components in equipment for IT 
power systems 
Class III equipment. 
 
 
 
 
- Page 11 of 19  - 
 
 
   
 
Order No.  23171 
 
 
1.5.01
 
LIST OF CRITICAL COMPONENTS
 
— 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted **) 
 
Enclosure 
DOW Emerge 
4330 -22 
Rated minimum 
flame class HB 
UL 94 
UL  
 
Alternative 
Various 
Various 
 
UL 94 
UL  
 
Jointronics 
PVC 
30 V, 80ºC 
Evaluated 
in unit 
UL 
 
Alternative 
Various 
Various 
30 V, 80ºC 
UL 94 
UL 
 
Various 
Various 
Rated minimum 
flame class V-2 
Evaluated 
in unit 
UL 
 
PCB material 
Various 
Various 
Rated minimum 
flame class V-1 or 
better 
Evaluated 
in unit 
UL  
 
Power 
amplifier IC  
ST Microelectronics 
TDA2007A 
6 W x 6 output 
Evaluated 
in unit 
None 
 
Speaker (4) 
Various 
1 inch, 
magnetically 
shielded 
6.8 
 
Evaluated 
in unit 
None 
 
Comments 
**) 
Marks listed under “Marks of conformity granted” indicates Nemko has verified the respective certifications. 
 
 
 
 
 
 
 
 
- Page 12 of 19  - 
 
 
   
 
Order No.  23171 
 
1.6 
POWER INTERFACE  
 
— 
1.6.1 
A.C. power distribution systems 
TN, and IT for Norway.  
— 
1.6.2 
Input current 
1 A  
— 
 
Test voltage (at each rated voltage 
or at each end of a rated voltage 
range)  
18 VDC  
 
 
Measured current   
Max current during normal operation 0.58 A @ 18 VDC 
 
Deviation 
Negative deviation is not limited. 
1.6.3 
Voltage limit of hand-held 
equipment (max. 250V)  
The equipment is not hand-held. 
1.6.4 
Neutral conductor  
Class III equipment. 
 
1.7 
MARKINGS AND INSTRUCTIONS  
 
— 
1.7.1 
Power rating  
The required marking is provided. 
 
Rated voltage 
18 V (dc symbol from IEC 60417, No. 5031) 
Refer to Copy of markings. 
 
Symbol for nature of supply for d.c. 
Provided. 
 
Rated frequency or frequency 
range 
DC. 
 
Rated current 
1 A 
 
Manufacturers name, trade mark or 
identification mark   
 
— 
 
Type / model   
on stage 
 
Symbol of Class II    
Class III equipment. 
 
Other symbols  
The additional marking does not give rise to 
misunderstandings. 
 
Certification marks   
Refer to label. 
— 
1.7.2 
Safety instructions 
Provided with marking regarding use of specified power 
supply, refer to marking label. 
 
Operating instructions  
 
Installation instructions are available to the user in 
User’s Manual. 
1.7.3 
Short duty cycles  
The equipment is intended for continuous operation.  
1.7.4 
Supply voltage adjustment  
No voltage selector. 
1.7.5 
Power outlets on the equipment 
No standard power outlet. 
1.7.6 
Fuse identification 
No fusing. 
1.7.7 
Wiring terminals 
Class III equipment. 
Page of 55