Order No.  23171 
 
4.5 
THERMAL REQUIREMENTS 
 
— 
4.5.1 
Temperature rises 
No thermostats, temp. limiters or thermal cut-outs. 
4.5.2 
Resistance to abnormal heat 
No such parts. 
 
Table 4.5.1 
TEMPERATURE RISES  
 
Test voltage  
18 VDC 
Parts on the circuit board:  Thermocouples were used to measure 
temperatures.  
 
t measured K 
U = 18.0 VDC  
t allowed 
C10 (rated 105 ºC) 
67 
80  
C8 (rated 105ºC) 
70 
80 
C23 (rated 105 ºC) 
42 
80 
C63 (rated 85ºC) 
29 
60 
C27 (rated 85ºC) 
36 
60 
U12 
32 
 
67 
70  
Ambient 
25 
— 
Comments 
Tmra = 25°C.  
 
4.6 
OPENINGS IN ENCLOSURES 
Class III equipment. 
 
4.7  
RESISTANCE TO FIRE  
Class III equipment, supplied by Limited Power Source 
complying with Sub-clause 2.5. 
 
5.1 
ELECTRICAL REQUIREMENTS 
AND SIMULATED ABNORMAL 
CONDITIONS
 
Class III equipment. 
 
5.2 
ELECTRIC STRENGTH  
Class III equipment. 
 
 
 
 
 
 
- Page 18 of 19  - 
 
 
   
 
Order No.  23171 
 
 
5.3 
ABNORMAL OPERATING AND 
FAULT CONDITIONS 
 
 
— 
5.3.1 
Protection against overload and 
abnormal operation 
See the enclosed fault condition test. 
5.3.2 
Motors 
There are no motors in the equipment. 
5.3.3 
Transformers 
There are no safety transformers in the equipment. 
5.3.4 
Functional Insulation 
Complies with a) and c). 
5.3.5 
Electromechanical components 
No electromechanical components. 
5.3.6 
Simulation of faults 
See the enclosed fault condition test. 
5.3.7 
Unattended equipment 
No thermostats, temperature limiters or thermal cut-outs. 
5.3.8 
Compliance criteria for abnormal 
operating and fault conditions 
Refer below: 
— 
5.3.8.1 
During the tests 
No fire or molten metal occurred and no deformation of 
enclosure during the tests. 
5.3.8.2 
After the tests 
No apparent effect from fault test. 
 
 
 
 
- Page 19 of 19  - 
 
 
   
 
Order No.  23171 
 
 
5.3.6 
FAULT CONDITION TESTS  
 
Ambient temperature  
   25°C 
F No 
Comp. 
No 
Fault  
Test 
voltage  
(V) 
Test 
time 
Fuse No 
Current  
(A) 
Mains power/temperatures/results 
Enclosure 
Blocked 
acoustic 
port 
18 VDC  
2.5 hours 
— 
0.395 
No effect.  No significant rise in 
temperatures.  No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O/l = Overload.
 
 
 
ELECTRICAL DATA (in normal 
conditions)
 
 
I rated 
(A) 
U in  
(V) 
Frequency 
(Hz) 
P in  
(W) 
I in measured 
(A) 
Conditions/status 
1A 
18 V  
DC 
9.9  
0.58 
Refer to Sub clause 1.2.2.1 
Comments 
 
 
 
 
CONNECTION TO 
TELECOMMUNICATION 
NETWORKS
  
No TNV circuits in the equipment. 
 
ANNEX A 
TESTS FOR RESISTANCE TO 
HEAT AND FIRE 
 
No additional testing required.   
Components adequately rated.  
 
ANNEX B 
MOTOR TESTS UNDER 
ABNORMAL CONDITIONS
 
No motors provided. 
 
ANNEX C 
TRANSFORMERS 
No isolating transformers in the equipment. 
 
ANNEX H 
IONIZING RADIATION 
No ionizing radiation. 
 
APPENDIX  
BATTERIES (4.3.8) 
Equipment not powered by batteries. 
 
 
 
 
APPENDIX 
EN 60950:2000  
- Page 1 of 10 - 
 
 
   
 
Order No.  23171 
 
APPENDIX    EN 60950:2000 
(IEC Publication 60950, 3rd edition, 1999) 
CENELEC Common Modifications, Special National Conditions, National Deviations and Other 
Information  
 
EXPLANATION FOR ABBREVIATIONS  
C = CENELEC Common Modification, S = Special National Condition,  A = National Deviation,  
F = Other Information;  AT = Austria, GB = Great Britain, CH = Switzerland, DE = Germany, DK = Denmark,  
ES = Spain, FI = Finland ,  FR = France, IE = Ireland, N O = Norway, SE = Sweden, ALL = All CENELEC Countries 
P = Pass, F = Fail, = Not applicable;  = No verdict required; placed in the column to the right 
1.2.4.1 S 
(DK) 
In Denmark, certain types of Class I 
appliances (see Sub-clause 3.2.1) may be 
provided with a plug not establishing earthing 
continuity when inserted into Danish socket-
outlets.  
Class III equipment. 
1.5.1 A 
(CH, SE) 
Add the following:  
NOTE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed.  
There are no components containing 
mercury in the equipment. 
1.5.8 S 
(NO) 
In Norway, due to the IT power system used, 
capacitors are required to be rated for the 
applicable phase -to-phase voltage (230V)
 
Class III equipment. 
1.7.2 S 
(NO) 
Class I Pluggable Equipment type A 
intended for connection to other equipment or a 
communication network shall, if safety relies on 
connection to protective earth, require a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet.  
Applicable text is: 
"Apparatet må kun tilkoples jordet stikkontakt" or  
"Jordet stikkontakt skal benyttes når apparatet 
tilkoples datanett"  
Class III equipment with no protective 
earth provided. 
1.7.2 S 
(SE) 
If the separation between the mains and 
SELV terminal relies upon connection to the 
safety earth, the apparatus shall have a marking 
stating that it must be connected to an earthed 
mains socket-outlet. 
The marking text shall be in Swedish and as 
follows: 
"Apparaten skall anslutas till jordat uttag när den 
ansluts till ett nätverk" or "Apparaten skall 
anslutas till jordat uttag". 
Class III equipment with no protective 
earth provided. 
 