JBL ON STAGE (serv.man3) EMC - CB Certificate ▷ View online
- Page 17 of 19 -
Order No. 23171
4.5
THERMAL REQUIREMENTS
—
4.5.1
Temperature rises
No thermostats, temp. limiters or thermal cut-outs.
N
4.5.2
Resistance to abnormal heat
No such parts.
N
Table 4.5.1
TEMPERATURE RISES
P
Test voltage
18 VDC
Parts on the circuit board: Thermocouples were used to measure
temperatures.
temperatures.
∆
t measured K
U = 18.0 VDC
∆
t allowed
K
C10 (rated 105 ºC)
67
80
C8 (rated 105ºC)
70
80
C23 (rated 105 ºC)
42
80
C63 (rated 85ºC)
29
60
C27 (rated 85ºC)
36
60
U12
32
—
67
70
Ambient
25
—
Comments
Tmra = 25°C.
4.6
OPENINGS IN ENCLOSURES
Class III equipment.
N
4.7
RESISTANCE TO FIRE
Class III equipment, supplied by Limited Power Source
complying with Sub-clause 2.5.
complying with Sub-clause 2.5.
P
5.1
ELECTRICAL REQUIREMENTS
AND SIMULATED ABNORMAL
CONDITIONS
AND SIMULATED ABNORMAL
CONDITIONS
Class III equipment.
N
5.2
ELECTRIC STRENGTH
Class III equipment.
N
- Page 18 of 19 -
Order No. 23171
5.3
ABNORMAL OPERATING AND
FAULT CONDITIONS
FAULT CONDITIONS
—
5.3.1
Protection against overload and
abnormal operation
abnormal operation
See the enclosed fault condition test.
P
5.3.2
Motors
There are no motors in the equipment.
N
5.3.3
Transformers
There are no safety transformers in the equipment.
N
5.3.4
Functional Insulation
Complies with a) and c).
P
5.3.5
Electromechanical components
No electromechanical components.
N
5.3.6
Simulation of faults
See the enclosed fault condition test.
P
5.3.7
Unattended equipment
No thermostats, temperature limiters or thermal cut-outs.
N
5.3.8
Compliance criteria for abnormal
operating and fault conditions
operating and fault conditions
Refer below:
—
5.3.8.1
During the tests
No fire or molten metal occurred and no deformation of
enclosure during the tests.
enclosure during the tests.
P
5.3.8.2
After the tests
No apparent effect from fault test.
P
- Page 19 of 19 -
Order No. 23171
5.3.6
FAULT CONDITION TESTS
P
Ambient temperature
25°C
F No
Comp.
No
No
Fault
Test
voltage
(V)
voltage
(V)
Test
time
time
Fuse No
Current
(A)
(A)
Mains power/temperatures/results
1
Enclosure
Blocked
acoustic
port
acoustic
port
18 VDC
2.5 hours
—
0.395
No effect. No significant rise in
temperatures. No hazard.
temperatures. No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O/l = Overload.
ELECTRICAL DATA (in normal
conditions)
conditions)
P
I rated
(A)
(A)
U in
(V)
(V)
Frequency
(Hz)
(Hz)
P in
(W)
(W)
I in measured
(A)
(A)
Conditions/status
1A
18 V
DC
9.9
0.58
Refer to Sub clause 1.2.2.1
Comments
6
CONNECTION TO
TELECOMMUNICATION
NETWORKS
TELECOMMUNICATION
NETWORKS
No TNV circuits in the equipment.
N
ANNEX A
TESTS FOR RESISTANCE TO
HEAT AND FIRE
HEAT AND FIRE
No additional testing required.
Components adequately rated.
Components adequately rated.
N
ANNEX B
MOTOR TESTS UNDER
ABNORMAL CONDITIONS
ABNORMAL CONDITIONS
No motors provided.
N
ANNEX C
TRANSFORMERS
No isolating transformers in the equipment.
N
ANNEX H
IONIZING RADIATION
No ionizing radiation.
N
APPENDIX
BATTERIES (4.3.8)
Equipment not powered by batteries.
N
APPENDIX
EN 60950:2000
- Page 1 of 10 -
Order No. 23171
APPENDIX EN 60950:2000
(IEC Publication 60950, 3rd edition, 1999)
CENELEC Common Modifications, Special National Conditions, National Deviations and Other
Information
CENELEC Common Modifications, Special National Conditions, National Deviations and Other
Information
EXPLANATION FOR ABBREVIATIONS
C = CENELEC Common Modification, S = Special National Condition, A = National Deviation,
F = Other Information; AT = Austria, GB = Great Britain, CH = Switzerland, DE = Germany, DK = Denmark,
ES = Spain, FI = Finland , FR = France, IE = Ireland, N O = Norway, SE = Sweden, ALL = All CENELEC Countries
P = Pass, F = Fail, N = Not applicable; — = No verdict required; placed in the column to the right
C = CENELEC Common Modification, S = Special National Condition, A = National Deviation,
F = Other Information; AT = Austria, GB = Great Britain, CH = Switzerland, DE = Germany, DK = Denmark,
ES = Spain, FI = Finland , FR = France, IE = Ireland, N O = Norway, SE = Sweden, ALL = All CENELEC Countries
P = Pass, F = Fail, N = Not applicable; — = No verdict required; placed in the column to the right
1.2.4.1 S
(DK)
In Denmark, certain types of Class I
appliances (see Sub-clause 3.2.1) may be
provided with a plug not establishing earthing
continuity when inserted into Danish socket-
outlets.
provided with a plug not establishing earthing
continuity when inserted into Danish socket-
outlets.
Class III equipment.
N
1.5.1 A
(CH, SE)
Add the following:
NOTE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
There are no components containing
mercury in the equipment.
mercury in the equipment.
P
1.5.8 S
(NO)
In Norway, due to the IT power system used,
capacitors are required to be rated for the
applicable phase -to-phase voltage (230V)
applicable phase -to-phase voltage (230V)
Class III equipment.
N
1.7.2 S
(NO)
Class I Pluggable Equipment type A
intended for connection to other equipment or a
communication network shall, if safety relies on
connection to protective earth, require a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
communication network shall, if safety relies on
connection to protective earth, require a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet stikkontakt" or
"Jordet stikkontakt skal benyttes når apparatet
tilkoples datanett"
"Apparatet må kun tilkoples jordet stikkontakt" or
"Jordet stikkontakt skal benyttes når apparatet
tilkoples datanett"
Class III equipment with no protective
earth provided.
earth provided.
N
1.7.2 S
(SE)
If the separation between the mains and
SELV terminal relies upon connection to the
safety earth, the apparatus shall have a marking
stating that it must be connected to an earthed
mains socket-outlet.
The marking text shall be in Swedish and as
follows:
"Apparaten skall anslutas till jordat uttag när den
ansluts till ett nätverk" or "Apparaten skall
anslutas till jordat uttag".
safety earth, the apparatus shall have a marking
stating that it must be connected to an earthed
mains socket-outlet.
The marking text shall be in Swedish and as
follows:
"Apparaten skall anslutas till jordat uttag när den
ansluts till ett nätverk" or "Apparaten skall
anslutas till jordat uttag".
Class III equipment with no protective
earth provided.
earth provided.
N