APPENDIX 
EN 60950:2000  
- Page 2 of 10 - 
 
 
   
 
Order No.  23171 
 
1.7.2 A 
(DK)
 Supply cords of Class I equipment, which is 
delivered witho ut a plug, must be provided with a 
visible tag with the following text:  
“Vigtigt! Lederen med grøn/gul isolation må kun 
tilsluttes en klemme mærket 
 eller 
 “ 
 
(IEC 60417, No 5019 eller IEC 60417, No. 5017) 
If essential for the safety of the equipment, the tag 
must in addition be provided with a diagram, 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende installationsvejledning" 
Class III equipment. 
1.7.5 S  
(DK) 
Socket-outlets for providing power to other 
equipment shall be in accordance with the Heavy 
Current Regulations, Section 107 -2-D1, Standard 
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used 
on Class I equipment  
There are no socket outlets providing 
mains power to other appliances. 
1.7.5 A  
(DK) 
Class II equipment shall not be fitted with 
socket-outlets for providing power to other 
equipment  
Class III equipment. 
1.7.12  A 
(DE) 
(Gesetz über techische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchfürung des 
Zweiten Abschnitts des 
Gerätesicherheitsgesetzes“ [General 
administrative regulation on the execution of the 
Second Section of the Equipment safety law], of 
10
th
 January 1996, article 2, 4
th
 paragraph item 2) 
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even 
only by service personnel are not exempted. 
Must be considered before marketed in 
Germany. 
— 
1.7.15 A 
(CH) 
(Ordinance on environmentally hazardous 
substances SR 814.013) Annex 4.10 of SR 
814.013 applies for batteries  
There is no battery containing Cd or Hg in 
the equipment. 
1.7.15 F 
(ALL) 
Warning texts for lithium batteries 
Languages:  
No batteries provided. 
2.2.4 S 
(NO) 
Requirements according to this Appendix, 
1.7.2 and 6.1.2.1 apply   
No TNV circuits. 
2.3.2 S  
(NO) 
Requirements according to this Appendix, 
6.1.2.1 apply  
No TNV circuits. 
2.3.3 S 
(NO) 
Requirements according to this Appendix, 
6.1.2.1 apply  
No TNV circuits. 
 
 
 
 
APPENDIX 
EN 60950:2000  
- Page 3 of 10 - 
 
 
   
 
Order No.  23171 
 
2.3.4 S  
(NO)
 Requirements according to this Appendix, 
1.7.2 and 6.1.2.1 apply   
No TNV circuits. 
2.7.1 C 
Replace the Sub-clause as follows: 
Basic requirements 
To protect against excessive current, short-circuits 
and earth faults in primary circuits, protective 
devices shall be included either as integral parts 
of the equipment or as parts of the building 
installation, subject to the following a), b) and c): 
 
a)  Except as detailed in b) and c), protective 
devices necessary to comply with the  
requirements of 5.3 shall be included as 
integral parts of the equipment. 
b)  For components in series with the mains input 
to the equipment such as the supply cord, 
appliance coupler,  r.f.i. filter and switch, short 
circuit and earth fault protection may be 
provided by protective devices in the building 
installation. 
c)  It is permitted for Pluggable Equipment type B 
or Permanently Connected Equipment, to rely 
on dedicated overcurrent and short circuit 
protection in the building installation, provided 
that the means of protection, e.g. fuses or 
circuit breakers, is fully specified in the 
installation instruction. 
 
If reliance is  placed on protection in the 
building installation, the installation instructions 
shall so state, except that for pluggable 
equipment type A the building installation shall 
be regarded as providing protection in 
accordance with the rating of the wall socket 
outlet.
 
 
Class III equipment. 
2.7.2 C  
This sub -clause has been declared: Void  
Considered. 
— 
2.10.3.1 S 
(NO)
 Due to the IT power distribution systems 
used, the a.c. mains supply voltage is considered 
to be equal to the line -to-line voltage, and will 
remain at 230V in case of a single earth fault 
Considered. 
 
 
 
 
APPENDIX 
EN 60950:2000  
- Page 4 of 10 - 
 
 
   
 
Order No.  23171 
 
3.2.1 S  
(CH) 
Supply cords of equipment having a rated 
current not exceeding 10A shall be provided with 
a plug complying with SEV 1011 or IEC 60884-1 
and one of the following dimension sheets: 
- SEV 6532-2.1991 Plug type 15, 3P+N+PE 
250/400V, 10A  
- SEV 6533-2.1991 Plug type 11,  L+N  
250V, 10A  
- SEV 6534-2.1991 Plug type 12,  L+N+PE  
250V, 10A  
In general, EN 60 309 applies for plugs for 
currents exceeding 10A. However, a 16A plug and 
socket-outlet system is being introduced in 
Switzerland, the plugs of which are according to 
the following dimension sheets, published in 
February 1998: 
- SEV 5932-2:1998 Plug type 25, 3L+N+PE 
230/400V, 16A  
- SEV 5933-2:1998 Plug type 21, L+N+PE 
250V, 16A  
- SEV 5934-2:1998 Plug type 23, L+N+PE 
250V, 16A  
Class III equipment. 
3.2.1 S  
(DK) 
Supply cords of single-phase equipment 
having a rated current not exceeding 10 A shall be 
provided with a plug according to the Heavy 
Current Regulations Section 107-2-D1 
Class I equipment provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection aga inst indirect 
contact is required according to the wiring rules, 
shall be provided with a plug in accordance with 
standard sheet DK 2-1a or DK 2-5a
 
If poly-phase equipment and single-phase 
equipment having a rated current exceeding 10A 
is provided with a supply cord with a plug, this 
plug shall be in accordance with the Heavy 
Current Regulations Section 107-1-D1 or 
EN 60 309-2 
Class III equipment. 
 
 
 
 
APPENDIX 
EN 60950:2000  
- Page 5 of 10 - 
 
 
   
 
Order No.  23171 
 
3.2.1 S  
(ES) 
Supply cords of single-phase equipment 
having a rated current not exceeding 10A shall be 
provided with a plug according to UNE 
20315:1994 
Supply cords of single -phase equipment having a 
rated current not exceeding 2.5A shall be 
provided with a plug according to UNE -EN 
50075:1993 
Class I equipment provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against indirect 
contact is required according to the wiring rules, 
shall be provided with a plug in accordance with 
standard UNE 20315:1994
 
If poly-phase equipment is provided with a supply 
cord with a plug, this plug shall be in accordance 
with UNE-EN 60309-2 
Class III equipment. 
3.2.1  
(GB) 
Apparatus which is fitted with a flexible cable 
or cord and is designed to be connected to a 
mains socket conforming to BS 1363 by means of 
that flexible cable or cord and plug, shall be fitted 
with a “standard plug” in accordance with 
Statutory Instrument 1768 :1994 - The Plugs and 
Sockets etc. (Safety) Regulations 1994, unless 
exempted by those regulations. 
NOTE: “standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved conversion 
plug.
  
Class III equipment. 
3.2.1  
(IE) 
Apparatus which is fitted with a flexible cable 
or cord and is designed to be connected to a 
mains socket conforming to I.S. 411 by means of 
that flexible cable or cord and plug shall be fitted 
with a 13A plug in accordance with Statutory 
Instrument 525 :1997 – National Standards 
Authority of Ireland (section 28) (13A Plugs and 
Conversions Adaptors for Domestic Use) 
Regulations 1997
  
Class III equipment. 
3.2.3 C  
Delete the NOTE 1 and in table 3A, delete the 
conduit sizes in parentheses  
Considered. 
3.2.5 C  
Replace  
"60245 IEC 53" by "H05 RR-F" 
"60227 IEC 52" by "H03 VV-F or H03 VVH2 -F" 
"60227 IEC 53" by "H05 VV-F or H05 VVH2 -F2"  
In table 3B, replace the first four lines by the 
following:  
Up to and including 6   0.75 
1)
 
Over 6 up to and including 10    (0.75) 
2)
   1.0  
Over 10 up to and including 16  (1.0) 
3)        
1.5  
In the Conditions applicable to table 3B, delete the 
words "in some countries" in condition 1). 
In NOTE 1, delete the second sentence.  
Considered. 
 
Page of 55