JBL ON STAGE (serv.man3) EMC - CB Certificate ▷ View online
- Page 13 of 19 -
Order No. 23171
1.7.8
Controls and indicators
No controls or figures provided.
N
1.7.9
Isolation of multiple power sources
Class III equipment.
N
1.7.10
IT power system
Class III equipment.
N
1.7.11
Thermostats and other regulating
devices
devices
No adjustable thermostats or other regulating devices.
N
1.7.12
Language
Instructions and equipment marking related to safety
shall be applied in a language, which is acceptable in
the country in which the equipment is to be sold.
shall be applied in a language, which is acceptable in
the country in which the equipment is to be sold.
—
1.7.13
Durability
The marking withstands required tests.
P
1.7.14
Removable parts
No safety or warning markings adhered to removable
parts.
parts.
P
1.7.15
Replaceable batteries
No lithium battery in the equipment.
N
1.7.16
Operator access with a tool
Class III equipment.
N
1.7.17
Equipment for restricted access
locations
locations
Equipment not intended for installation in RAL.
N
Copy of the markings:
- Page 14 of 19 -
Order No. 23171
2
PROTECTION FROM HAZARDS
Class III equipment.
N
2.1
PROTECTION FROM ELECTRIC
SHOCK AND ENERGY HAZARDS
SHOCK AND ENERGY HAZARDS
Class III equipment powered by Limited Power Source.
P
2.2
SELV CIRCUITS
Class III equipment powered by Limited Power Source.
P
2.3
TNV CIRCUITS
No TNV circuits in the equipment.
N
2.4
LIMITED CURRENT CIRCUITS
No limited current circuits.
N
2.5
LIMITED POWER SOURCES
Class III equipment powered by Limited Power Source.
P
2.6
PROVISIONS FOR EARTHING
AND BONDING
AND BONDING
Class III equipment.
N
2.7
OVERCURRENT AND EARTH
FAULT PROTECTION IN
PRIMARY CIRCUITS
FAULT PROTECTION IN
PRIMARY CIRCUITS
Class III equipment.
N
2.8
SAFETY INTERLOCKS
No safety interlocks.
N
2.9
ELECTRICAL INSULATION
Class III equipment, only Functional insulation used.
N
2.10
CLEARANCES, CREEPAGE
DISTANCES AND DISTANCES
THROUGH INSULATION
DISTANCES AND DISTANCES
THROUGH INSULATION
Class III equipment, only Functional insulation used.
N
- Page 15 of 19 -
Order No. 23171
3
WIRING, CONNECTIONS AND
SUPPLY
SUPPLY
—
3.1
GENERAL
—
3.1.1
Current rating and overcurrent
protection
protection
Class III equipment powered by an external Limited
Power Source.
Power Source.
N
3.1.2
Protection against mechanical
damage
damage
Wires are adequately fixed to prevent excessive strain
on wire and terminals and avoiding damage to the
insulation of the conductors.
on wire and terminals and avoiding damage to the
insulation of the conductors.
P
3.1.3
Securing of internal wiring
Refer to Sub-clause 3.1.2.
P
3.1.4
Insulation of conductors
Only internal wiring at SELV levels.
N
3.1.5
Beads and ceramic insulators
No beads or similar ceramic insulators on conductors.
N
3.1.6
Screws for electrical contact
pressure
pressure
No screws used for electrical contact.
N
3.1.7
Non-metallic materials in electrical
connections
connections
No contact pressure through insulating material.
P
3.1.8
Self-tapping and spaced thread
screws
screws
Thread-cutting or space thread screws are not used for
electrical connections.
electrical connections.
P
3.1.9
Termination of conductors
Class III equipment powered by an external Limited
Power Source.
Power Source.
N
3.1.10
Sleeving on wiring
No such sleeving used.
N
3.2
CONNECTION TO A.C. MAINS
SUPPLIES
SUPPLIES
Class III equipment, see Summary of Testing.
N
3.3
WIRING TERMINALS FOR
CONNECTION OF EXTERNAL
CONDUCTORS
CONNECTION OF EXTERNAL
CONDUCTORS
Class III equipment.
N
3.4
DISCONNECTION FROM THE
A.C. MAINS SUPPLY
A.C. MAINS SUPPLY
Class III equipment.
N
3.5
INTERCONNECTION OF
EQUIPMENT
EQUIPMENT
Class III equipment.
P
- Page 16 of 19 -
Order No. 23171
4
PHYSICAL REQUIREMENTS
—
4.1
Stability
Refer below:
—
Angle of 10°
Unit does not overbalance at 10°.
P
Test: force (20% of the weight of
the unit, max. 250N)
the unit, max. 250N)
The unit is not floor-standing.
N
Test: force (800N)
The unit is not floor-standing.
P
4.2
MECHANICAL STRENGTH
Class III equipment
N
4.3
DESIGN AND CONSTRUCTION
—
4.3.1
Edges and corners
No edges or corners.
N
4.3.2
Handles and manual controls
Class III equipment, no hazardous voltages.
N
4.3.3
Adjustable controls
No hazardous adjustable controls.
N
4.3.4
Securing of parts
Class III equipment, no hazardous voltages.
N
4.3.5
Connection of plugs and sockets
SELV and TNV connectors do not comply with IEC
60320 or IEC 60083.
60320 or IEC 60083.
P
4.3.6
Direct plug -in equipment
Not intended to plug directly into a wall socket-outlet.
N
4.3.7
Heating elements in earthed
equipment
equipment
No heating elements provided.
N
4.3.8
Batteries
No batteries in equipment.
N
4.3.9
Oil and grease
Insulation is not exposed to oil, grease etc.
N
4.3.10
Dust, powders, liquids and gases
The equipment does not generate ionizing radiation or
use a laser, and does not contain flammable liquids or
gases.
use a laser, and does not contain flammable liquids or
gases.
N
4.3.11
Containers for liquids or gases
No containers for liquids or gases in the equipment.
N
4.3.12
Flammable liquids
The equipment does not contain flammable liquid.
N
4.3.13
Radiation
The equipment does not generate ionizing radiation or
use a laser, and does not contain flammable liquids or
gases. LEDs are diffused type.
use a laser, and does not contain flammable liquids or
gases. LEDs are diffused type.
N
4.4
PROTECTION AGAINST
HAZARDOUS MOVING PARTS
HAZARDOUS MOVING PARTS
No moving parts.
N
Click on the first or last page to see other ON STAGE (serv.man3) service manuals if exist.