JBL ON STAGE (serv.man3) EMC - CB Certificate ▷ View online

IEC 60950 3rd. Ed, 1999 
- Page 3 of 5 - 
 
 
 
 
Order No.  23171 
 
4.3.12 
The maximum quantity of flammable liquid 
stored in equipment is required to comply  with 
NFPA 30. 
No flammable liquids within the 
equipment. 
4.3.13 
Equipment with lasers is required to meet 
Code of Federal Regulations 21CFR 1040 and 
Canadian Radiation Emitting Devices Act, 
REDR C1370.  
LEDs are defused type. 
4.7.1  
For computer room applications, automated 
information storage systems with combustible 
media greater than 27 cubic feet are required 
to have a provision for connection of either 
automatic sprinklers or a gaseous agent 
extinguishing system with an extended 
discharge. 
The equipment has no combustible 
area greater than 27 cubic feet. 
4.7.3.1 
For computer room applications, enclosures 
with combustible material measuring greater 
than 0.9 m
2
 or a single dimension greater than 
1.8 m, are required to have a flame spread 
rating of 50 or less. For other applications, 
enclosures with the same dimensions require a 
flame spread rating of 200 or less. 
The equipment has no combustible 
material greater than 0.93m2 or 
single dimension greater than 1.8m. 
Annex H 
Equipment that produces ionizing radiation is 
required to comply with Code of Federal 
Regulations, 21 CFR 1020 and Canadian 
Radiation Emitting Devices Act, REDR C1370. 
The equipment does not produce 
ionizing radiation. 
IEC 60950 3rd. Ed, 1999 
- Page 4 of 5 - 
 
 
 
 
Order No.  23171 
 
 
 
The following key national differences are based on re quirements other than 
national regulatory requirements. The bi-national standard referenced above 
should be consulted for further details on the national differences summarized 
below. 
— 
1.5.1  
Some components and materials associated 
with the risk of fire, electric shock, or personal 
injury are required to have component or 
material ratings in accordance with the 
applicable national (U.S. and Canadian) 
component or material requirements.  
These components include:  
attachment plugs, cathode ray tubes, circuit 
breakers, communication circuit accessories, 
cord sets and power supply cords, direct plug-
in equipment, enclosures (outdoor), flexible 
cords and cables, fuses (branch circuit), 
fuseholders, ground-fault current interrupters, 
industrial control equipment, insulating tape, 
interconnecting cables, lampholders, limit 
controls, printed wiring, protectors for 
communications circuits, receptacles, solid 
state controls, supplementary protectors, surge 
suppressors, switches (including interlock 
switches), thermal cutoffs, thermostats, 
transformer winding wire, tubing, wire 
connectors and wire and cables    
All critical components are IEC, UL 
or CSA certified. See list of critical 
components in main CB report 
(§1.5.01).  
2.3.1  
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 
42.4 Vp or 60 Vdc, the maximum acceptable 
current through a 2000 ohm resistor (or 
greater) connected across the voltage source 
with other loads disconnected is 7.1 mA peak 
or 30 mA dc under normal operating 
conditions. 
No TNV circuitry. 
2.6.3.3 
When subject to impedance testing, protective 
earthing and bonding is required to be tested 
subject per the specified test conditions that 
originate in CSA C22.2 No. 0.4. 
Class III equipment. 
4.2.8.1 
Enclosures around CRT’s with a face area of 
160 mm or more are required to reduce the 
risk of injury due to the implosion of the CRT. 
No CRTs in the equipment. 
IEC 60950 3rd. Ed, 1999 
- Page 5 of 5 - 
 
 
 
 
Order No.  23171 
 
 
4.3.2  
Equipment with handles is required to comply 
with special loading tests. 
The equipment is  not provided with 
handles. 
5.1.8.1.1 
Equipment intended to receive 
telecommunication ringing signals is required 
to comply with a special touch current 
measurement tests. 
No TNV circuitry. 
6.2.1  
Enamel coating on winding wire not 
considered electrical separation unless 
subjected to special investigation. 
No TNV circuitry. 
6.4  
Equipment intended for connection to 
telecommunication network outside plant cable 
is required to be protected against overvoltage 
from power line crosses in accordance with 6 .4 
and Annex NAC. 
No TNV circuitry. 
6.5  
Equipment connected to a telecommunications 
network and supplied with an earphone 
intended to be held against, or in the ear is 
required to comply with special acoustic 
pressure tests. 
No TNV circuitry. 
M.2 
Continuous ringing signals up to 16mA only 
are permitted if the equipment is subject to 
special installation and performance 
restrictions. 
No TNV circuitry. 
Annex NAB  Equipment connected to centralized d.c. power 
systems is required to comply with special 
earthing, wiring, marking and insulation 
requirements in accordance with Annex NAB 
and 3.6.1. 
The equipment is not connected to 
a centralized d.c. power system. 
IEC 60950 3rd. Ed, 1999 
- Page 5 of 5 - 
 
 
 
 
Order No.  23171 
 
 
4.3.2  
Equipment with handles is required to comply 
with special loading tests. 
The equipment is  not provided with 
handles. 
5.1.8.1.1 
Equipment intended to receive 
telecommunication ringing signals is required 
to comply with a special touch current 
measurement tests. 
No TNV circuitry. 
6.2.1  
Enamel coating on winding wire not 
considered electrical separation unless 
subjected to special investigation. 
No TNV circuitry. 
6.4  
Equipment intended for connection to 
telecommunication network outside plant cable 
is required to be protected against overvoltage 
from power line crosses in accordance with 6 .4 
and Annex NAC. 
No TNV circuitry. 
6.5  
Equipment connected to a telecommunications 
network and supplied with an earphone 
intended to be held against, or in the ear is 
required to comply with special acoustic 
pressure tests. 
No TNV circuitry. 
M.2 
Continuous ringing signals up to 16mA only 
are permitted if the equipment is subject to 
special installation and performance 
restrictions. 
No TNV circuitry. 
Annex NAB  Equipment connected to centralized d.c. power 
systems is required to comply with special 
earthing, wiring, marking and insulation 
requirements in accordance with Annex NAB 
and 3.6.1. 
The equipment is not connected to 
a centralized d.c. power system. 