DOWNLOAD JBL ON BEAT AIR (serv.man3) Service Manual ↓ Size: 2.02 MB | Pages: 123 in PDF or view online for FREE

Model
ON BEAT AIR (serv.man3)
Pages
123
Size
2.02 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-beat-air-sm3.pdf
Date

JBL ON BEAT AIR (serv.man3) EMC - CB Certificate ▷ View online

ATTACHMENT
 
 
National Differences 
 
 
Page 112 of 116 
 
Report No.:  11023927 001 
National Differences 
Clause 
Requirement + Test 
Result – Remark 
Verdict 
 
 
 
JA.2 
INADVERTENT REACTIVATION 
 
Any safety interlock which can be operated by 
means of the test finger, Figure JA.1, is 
considered to cause reactivation of the hazard. 
 
Compliance is checked by inspection and, where 
necessary, by a test with the test finger, Figure 
JA.1.  
Added. 
Product is DC Power Supply 
Unit, not Paper Shredder. 
N/A 
 
                                Figure JA.1 Test finger 
ATTACHMENT
 
 
National Differences 
 
 
Page 113 of 116 
 
Report No.:  11023927 001 
National Differences 
Clause 
Requirement + Test 
Result – Remark 
Verdict 
 
 
JA.3 
ISOLATING SWITCH 
 
Document shredding machines shall incorporate 
an isolating switch complying with sub-clause 
3.4.2 as the device disconnecting the power of 
hazardous moving parts. For this switch, two-
position (single-use) switch or multi-position 
(multifunction) switch (e.g., slide switch) may be 
used.  
 
If two-position switch, the positions for  “ON” and 
“OFF” shall be indicated in accordance with sub-
clause 1.7.8. If multi-position switch, the position 
for “OFF” shall be indicated in accordance with 
sub-clause 1.7.8 and other positions shall be 
indicated with proper terms or symbols. 
 
Compliance is checked by inspection. 
Added. 
Product is DC Power Supply 
Unit, not Paper Shredder. 
N/A 
JA.4 
PROTECTION IN OPERATOR ACCESS AREAS 
 
Any warning shall not be used instead of the 
structure for preventing access to hazardous 
moving parts. 
Document shredding machines shall comply with 
the following requirements. 
 
Push the test finger, Figure JA.1, into all 
openings in MECHANICAL ENCLOSURES 
without applying additional force. It shall not be 
possible to touch hazardous moving parts with 
the test finger. The document shredding machine 
is installed as intended, and all face of 
MECHANICAL ENCLOSURES are subjected to 
this test. Before testing with the test finger, 
remove the parts detachable without a tool. 
 
Push the wedge-probe, Figure JA.2, into the 
document-slot. And, against all directions of 
openings, if straight-cutting type, a force of 45 N 
shall apply to the probe, and 90 N if cross-cutting 
type. In this case, the weight of the probe shall 
not influence the test. Before testing withy the 
test finger, remove the parts detachable without 
a tool. It shall not be possible to touch any 
hazardous moving parts, including the shredding 
roller or the mechanical section for shedding, 
with the probe. 
Added. 
Product is DC Power Supply 
Unit, not Paper Shredder. 
N/A 
ATTACHMENT
 
 
NATIONAL DIFFERENCES 
 
 
Page 114 of 116 
 
Report No.: 11022328 001 
 
 
 
 
 
 
(Details of the top of wedge) 
 
 
 
 
 
 
Note 2 –The allowable dimensional tolerance of the probe is +/- 0.127 mm. 
 
Figure JA.2 Wedge-probe 
 
 
 
 
Distance from the top 
Thickness of probe 
12 
180 
24 
Note 1 -  The probe shall be of changing the thickness linearly. However, the slope shall be changed at the 
respective points shown in the table. 
ATTACHMENT
 
 
National Differences 
 
 
Page 115 of 116 
 
Report No.: 11023927 001 
National Differences 
Clause 
Requirement + Test 
Result – Remark 
Verdict 
 
 
Appendix 
J3000 (H21)  
Special National conditions, National deviation and other information according to 
MITI Ordinance No. 85. 
 
General requirement 
When equipment provides with appliance inlet 
complying with JIS-C 8283-1(2008), soldered 
parts of appliance inlet is not applied by force 
during insert or removal of connector. 
This is not applied when inlet body is fixed itself 
and not fixed by solder.  
 
Inlet is fixed by adequate 
mechanical enclosure 
construction, not rely on 
soldering. The inlet L/N pins are  
connected to PCB via wires 
Requirement for equipment 
 
2.1 
Electric heater 
When diode is used in parallel for adjustment of 
power, the equipment shall remain safe for 
operation under open condition of one diode. 
Not electric stove. 
N/A 
 
The current rating of one diode shall be more 
than main current.  The diodes connected in 
parallel are same type. 
 
N/A 
 
The heating test specified by clause 11 of JIS C 
9335-2-30(2006) under open condition of one 
diode shall comply with the requirements. 
 
N/A 
2.2 
Electric heater with glowing heating elements 
Not electric stove. 
N/A 
 
Surface treatment by paint or adhesive on 
protective frame or protective mesh shall not be 
used. 
 
N/A 
 
Caution marking like below shall be on  
-  easily visible place of the equipment or 
-  Instruction manual 
「注意  当該機器から、使用初期段階で揮発性有
機化合物およびカルボニル化合物が最も放散する
おそれがあるため、その際には十分換気を行うこ
と。」
 
 
N/A 
 
Page of 123
Display

Click on the first or last page to see other ON BEAT AIR (serv.man3) service manuals if exist.