JBL ON BEAT AIR (serv.man3) EMC - CB Certificate ▷ View online
ATTACHMENT
National Differences
Page 112 of 116
Report No.: 11023927 001
National Differences
Clause
Requirement + Test
Result – Remark
Verdict
JA.2
INADVERTENT REACTIVATION
Any safety interlock which can be operated by
means of the test finger, Figure JA.1, is
considered to cause reactivation of the hazard.
Compliance is checked by inspection and, where
necessary, by a test with the test finger, Figure
JA.1.
necessary, by a test with the test finger, Figure
JA.1.
Added.
Product is DC Power Supply
Unit, not Paper Shredder.
Unit, not Paper Shredder.
N/A
Figure JA.1 Test finger
ATTACHMENT
National Differences
Page 113 of 116
Report No.: 11023927 001
National Differences
Clause
Requirement + Test
Result – Remark
Verdict
JA.3
ISOLATING SWITCH
Document shredding machines shall incorporate
an isolating switch complying with sub-clause
3.4.2 as the device disconnecting the power of
hazardous moving parts. For this switch, two-
position (single-use) switch or multi-position
(multifunction) switch (e.g., slide switch) may be
used.
If two-position switch, the positions for “ON” and
“OFF” shall be indicated in accordance with sub-
clause 1.7.8. If multi-position switch, the position
for “OFF” shall be indicated in accordance with
sub-clause 1.7.8 and other positions shall be
indicated with proper terms or symbols.
Compliance is checked by inspection.
Added.
Product is DC Power Supply
Unit, not Paper Shredder.
Unit, not Paper Shredder.
N/A
JA.4
PROTECTION IN OPERATOR ACCESS AREAS
Any warning shall not be used instead of the
structure for preventing access to hazardous
moving parts.
Document shredding machines shall comply with
the following requirements.
Push the test finger, Figure JA.1, into all
openings in MECHANICAL ENCLOSURES
without applying additional force. It shall not be
possible to touch hazardous moving parts with
the test finger. The document shredding machine
is installed as intended, and all face of
MECHANICAL ENCLOSURES are subjected to
this test. Before testing with the test finger,
remove the parts detachable without a tool.
Push the wedge-probe, Figure JA.2, into the
document-slot. And, against all directions of
openings, if straight-cutting type, a force of 45 N
shall apply to the probe, and 90 N if cross-cutting
type. In this case, the weight of the probe shall
not influence the test. Before testing withy the
test finger, remove the parts detachable without
a tool. It shall not be possible to touch any
hazardous moving parts, including the shredding
roller or the mechanical section for shedding,
with the probe.
Added.
Product is DC Power Supply
Unit, not Paper Shredder.
Unit, not Paper Shredder.
N/A
ATTACHMENT
NATIONAL DIFFERENCES
Page 114 of 116
Report No.: 11022328 001
(Details of the top of wedge)
Note 2 –The allowable dimensional tolerance of the probe is +/- 0.127 mm.
Figure JA.2 Wedge-probe
Distance from the top
Thickness of probe
0
2
12
4
180
24
Note 1 - The probe shall be of changing the thickness linearly. However, the slope shall be changed at the
respective points shown in the table.
respective points shown in the table.
ATTACHMENT
National Differences
Page 115 of 116
Report No.: 11023927 001
National Differences
Clause
Requirement + Test
Result – Remark
Verdict
Appendix
J3000 (H21)
Special National conditions, National deviation and other information according to
MITI Ordinance No. 85.
MITI Ordinance No. 85.
1
General requirement
When equipment provides with appliance inlet
complying with JIS-C 8283-1(2008), soldered
parts of appliance inlet is not applied by force
during insert or removal of connector.
complying with JIS-C 8283-1(2008), soldered
parts of appliance inlet is not applied by force
during insert or removal of connector.
This is not applied when inlet body is fixed itself
and not fixed by solder.
and not fixed by solder.
Inlet is fixed by adequate
mechanical enclosure
construction, not rely on
soldering. The inlet L/N pins are
connected to PCB via wires
mechanical enclosure
construction, not rely on
soldering. The inlet L/N pins are
connected to PCB via wires
P
2
Requirement for equipment
2.1
Electric heater
When diode is used in parallel for adjustment of
power, the equipment shall remain safe for
operation under open condition of one diode.
power, the equipment shall remain safe for
operation under open condition of one diode.
Not electric stove.
N/A
The current rating of one diode shall be more
than main current. The diodes connected in
parallel are same type.
than main current. The diodes connected in
parallel are same type.
N/A
The heating test specified by clause 11 of JIS C
9335-2-30(2006) under open condition of one
diode shall comply with the requirements.
9335-2-30(2006) under open condition of one
diode shall comply with the requirements.
N/A
2.2
Electric heater with glowing heating elements
Not electric stove.
N/A
Surface treatment by paint or adhesive on
protective frame or protective mesh shall not be
used.
protective frame or protective mesh shall not be
used.
N/A
Caution marking like below shall be on
- easily visible place of the equipment or
- Instruction manual
- easily visible place of the equipment or
- Instruction manual
「注意 当該機器から、使用初期段階で揮発性有
機化合物およびカルボニル化合物が最も放散する
おそれがあるため、その際には十分換気を行うこ
と。」
機化合物およびカルボニル化合物が最も放散する
おそれがあるため、その際には十分換気を行うこ
と。」
N/A
Click on the first or last page to see other ON BEAT AIR (serv.man3) service manuals if exist.