Report No. SF201200115                                                                                                        Page 9 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
 
Flames extinguish within 10 seconds 
No flames. 
 
Soldered  terminations  not  used    as  protective 
mechanism 
 
11.2.1 
Measurement of temperature rises 
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts 
(see appended table 11.2) 
11.2.3 
Temperature  rise  of  parts,  other  than  windings, 
providing electrical insulation 
 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 
 
a)  Temperature  rise  of  printed  circuit  boards 
(PCB)  to  20.1.3,  exceeding  the  limits  of  table 3 
by not more than 100 K for an area not greater 
than 2 cm
² 
 
 
b)  Temperature  rise  of  printed  circuit  boards 
(PCB)  to  20.1.3  up  to  300 K  for  an  area  not 
greater than 2 cm
² for a maximum of 5 min 
 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
 
Class I protective earthing maintained 
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table 11.2) 
 
 
 
12 
MECHANICAL STRENGTH 
12.1.1 
Bump test where mass >7 kg 
 
12.1.2 
Vibration test 
No hazardous live parts. 
12.1.3 
Impact hammer test 
 
 
Steel ball test 
 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Not such apparatus. 
12.1.5 
Thermoplastic enclosures strain relief test 
No hazardous live parts. 
12.2 
Fixing of knobs, push buttons, keys and levers 
No hazardous live parts. 
12.3 
Remote controls with hazardous live parts 
No such component 
12.4 
Drawers (pull test 50 N, 10 s) 
No such component 
12.5 
Antenna coaxial sockets providing isolation 
 
12.6 
Telescoping or rod antennas construction 
No such component 
Report No. SF201200115                                                                                                        Page 10 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
12.6.1 
Telescoping or rod antennas securement 
 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
13.1 
Clearances in accordance with 13.3 
No insulation requirement. 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
Supplied  by  12V  DC,  no 
hazardous  voltage  generate 
circuit in the apparatus. 
13.3 
Clearances 
 
13.3.1 
General 
 
13.3.2 
Circuits  conductively  connected  to  the  mains 
comply with table 8 and, where applicable, table 
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 
13.3.4 
Measurement of transient voltages 
 
13.4 
Creepage distances 
 
 
Creepage  distances  greater  than  table  11 
minima 
 
13.5 
Printed boards 
 
13.5.1 
Clearances  and  creepage  distances  between 
conductors  on  printed  circuit  boards,  one  of 
which  may  be  conductively  connected  to  the 
mains, as in fig. 10 
 
13.5.2 
Type B  coated  printed  circuit  boards  complying 
with IEC 60664-3 (basic insulation only) 
 
13.6 
Conductive  parts  along  uncemented  joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
 
Conductive  parts  along  reliably  cemented  joints 
comply with 8.8 
 
 
Temperature  cycle  test  and  dielectric  strength 
test 
 
13.7 
Enclosed,  enveloped  or  hermetically  sealed 
parts:  not  conductively  connected  to  the  mains: 
clearances  and  creepage  distances  as  in 
table 12 
 
13.8 
Parts  filled  with  insulating  compound,  meeting 
the requirements of 8.8 
 
Report No. SF201200115                                                                                                        Page 11 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
 
 
 
14 
COMPONENTS 
14.1 
Resistors 
 
a)  Resistors  between  hazardous  live  parts  and 
accessible metal parts 
(see appended table) 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 
 
Resistors separately approved  .......................... :  Yes / No 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes / No 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition 
.............................................................................. : 
Y1 
Y2 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition 
.............................................................................. : 
X1 
X2 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ................. : 
 
14.2.5 
Capacitors  with  volume  exceeding  1750 mm
³, 
where  short-circuit  current  exceeds  0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ................................................................... : 
Metal-cased capacitors 
 
Capacitors  with  volume  exceeding  1750 mm
³, 
mounted  closer  to  a  potential  ignition  source 
than 
table 5 
permits: 
compliance 
with 
IEC 60 384-1, 4.38 category B or better ............ : 
 
 
Shielded by a barrier 
acc. to 20.1.4/ table 21
 or 
metal .................................................................... : 
Yes / No 
14.3 
Inductors and windings 
No such component 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 
14.3.1 
Transformers  and  inductors  marked  with 
manufacturer's name and type ........................... : 
 
 
Transformers 
and 
inductors 
separately 
approved  ............................................................. : 
Yes / No 
14.3.2 
General 
 
 
Insulation material complies    with clause 20.1.4   
14.3.3 
Constructional requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 
14.3.3.2 
Transformers 
meet 
the 
constructional 
requirements 
 
Report No. SF201200115                                                                                                        Page 12 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
14.3.4.1 
Class II  transformers  have  adequate  separation 
between  hazardous  live  parts  and  accessible 
parts (double or reinforced insulation) 
 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.4.2 
Class I  transformers,  with  basic  insulation  and 
protective  screening  only  if  all  7  conditions  of 
14.3.4.2 are met 
 
14.3.4.3 
Separating  transformers  with  at  least  basic 
insulation 
 
14.3.5.1 
Class II  transformers  have  adequate  insulation 
between  hazardous  live  parts  and  accessible 
parts (double or reinforced insulation) 
 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.5.2 
Class I  transformers  have  adequate  insulation 
between  hazardous  live  parts  and  accessible 
conductive  parts  or  those  conductive  parts  or 
protective  screens  connected  to  a  protective 
earth terminal 
 
 
Winding  wires  connected  to  protective  earth 
have adequate current-carrying capacity 
 
14.4 
High voltage components 
No high voltage components 
 
High-voltage  components  and  assemblies: 
U > 4 kV (peak) separately approved 
(see appended table) 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested 
as part of the submission 
 
14.4.2 
High  voltage  assemblies  and  other  parts  tested 
as part of the submission 
 
14.5 
Protective devices 
 
 
Protective devices used within their ratings 
 
 
External  clearances  and  creepage  distances 
meet  requirement  of  clause  13  for  the  voltage 
across the device when opened 
No insulation requirement. 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such component 
 
b)  Thermal  cut-outs  tested  as  part  of  the 
submission 
 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission   
14.5.1.3 
Thermal devices re-settable by soldering 
 
14.5.2.1 
Fuse-links  in  the mains  circuit  according  to  IEC 
60127 
Not connect to the mains. 
see appended table 14 
Page of 32