JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. SF201200115 Page 9 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Flames extinguish within 10 seconds
No flames.
P
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
N
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N
a) Temperature rise of printed circuit boards
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm
²
N
b) Temperature rise of printed circuit boards
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm
² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N
11.2.5
Temperature rise of windings
N
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table 11.2)
P
12
MECHANICAL STRENGTH
N
12.1.1
Bump test where mass >7 kg
N
12.1.2
Vibration test
No hazardous live parts.
N
12.1.3
Impact hammer test
N
Steel ball test
N
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Not such apparatus.
N
12.1.5
Thermoplastic enclosures strain relief test
No hazardous live parts.
N
12.2
Fixing of knobs, push buttons, keys and levers
No hazardous live parts.
N
12.3
Remote controls with hazardous live parts
No such component
N
12.4
Drawers (pull test 50 N, 10 s)
No such component
N
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
No such component
N
Report No. SF201200115 Page 10 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
N
13.1
Clearances in accordance with 13.3
No insulation requirement.
N
Creepage distances in accordance with 13.4
N
13.2
Determination of operating voltage
Supplied by 12V DC, no
hazardous voltage generate
circuit in the apparatus.
hazardous voltage generate
circuit in the apparatus.
N
13.3
Clearances
N
13.3.1
General
N
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table
9
comply with table 8 and, where applicable, table
9
N
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N
13.3.4
Measurement of transient voltages
N
13.4
Creepage distances
N
Creepage distances greater than table 11
minima
minima
N
13.5
Printed boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of
which may be conductively connected to the
mains, as in fig. 10
conductors on printed circuit boards, one of
which may be conductively connected to the
mains, as in fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
Temperature cycle test and dielectric strength
test
test
N
13.7
Enclosed, enveloped or hermetically sealed
parts: not conductively connected to the mains:
clearances and creepage distances as in
table 12
parts: not conductively connected to the mains:
clearances and creepage distances as in
table 12
N
13.8
Parts filled with insulating compound, meeting
the requirements of 8.8
the requirements of 8.8
N
Report No. SF201200115 Page 11 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14
COMPONENTS
P
14.1
Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
(see appended table)
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
Resistors separately approved .......................... : Yes / No
N
14.2
Capacitors and RC units
N
Capacitors separately approved
Yes / No
N
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition
.............................................................................. :
Y1
Y2
Y2
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition
.............................................................................. :
X1
X2
X2
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ................. :
connected to the mains: tests for X2 ................. :
N
14.2.5
Capacitors with volume exceeding 1750 mm
³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ................................................................... :
compliance with IEC60384-1, 4.38 category B or
better ................................................................... :
Metal-cased capacitors
N
Capacitors with volume exceeding 1750 mm
³,
mounted closer to a potential ignition source
than
than
table 5
permits:
compliance
with
IEC 60 384-1, 4.38 category B or better ............ :
N
Shielded by a barrier
acc. to 20.1.4/ table 21
or
metal .................................................................... :
Yes / No
N
14.3
Inductors and windings
No such component
N
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N
14.3.1
Transformers and inductors marked with
manufacturer's name and type ........................... :
manufacturer's name and type ........................... :
N
Transformers
and
inductors
separately
approved ............................................................. :
Yes / No
N
14.3.2
General
N
Insulation material complies with clause 20.1.4
N
14.3.3
Constructional requirements
N
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
N
14.3.3.2
Transformers
meet
the
constructional
requirements
N
Report No. SF201200115 Page 12 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
N
Coil formers and partition walls > 0,4 mm
N
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
N
Winding wires connected to protective earth
have adequate current-carrying capacity
have adequate current-carrying capacity
N
14.4
High voltage components
No high voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
(see appended table)
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N
14.4.2
High voltage assemblies and other parts tested
as part of the submission
as part of the submission
N
14.5
Protective devices
N
Protective devices used within their ratings
N
External clearances and creepage distances
meet requirement of clause 13 for the voltage
across the device when opened
meet requirement of clause 13 for the voltage
across the device when opened
No insulation requirement.
N
14.5.1.1
a) Thermal cut-outs separately approved
No such component
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Not connect to the mains.
see appended table 14
N
Click on the first or last page to see other JEMBE WIRELESS (serv.man2) service manuals if exist.