Report No. SF201200115 Page 13 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5.2.2
Correct marking of fuse-links adjacent to holder :
N
14.5.2.3
Not possible to connect fuses in parallel ........... :
N
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ..... :
replacing fuse-links without the use of a tool ..... :
N
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such component.
N
PTC-S devices (15 W) category V-1 or better
N
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N
14.6
Switches
Functional switch used.
N
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
N
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1
61058-1
subclause
13.1
and
has
making/breaking action independent of speed
of actuation
of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not
attaining excessive temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate
dielectric strength
dielectric strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N
Socket outlet current marking correct
N
14.7
Safety interlocks
No safety interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
Report No. SF201200115 Page 14 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.8
Voltage setting devices and the like
No such component
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9
Motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors
with
phase-shifting
capacitors,
three-phase motors and series motors meet
clause. B.8, B.9 and B.10 of IEC 60950,
Annex B
clause. B.8, B.9 and B.10 of IEC 60950,
Annex B
Not such motors.
N
14.10
Batteries
Battery in remote control.
P
14.10.1
Batteries mounted with no risk of accumulation
of flammable gases
of flammable gases
P
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
P
14.10.3
Recharging
currents
and
times
within
manufacturers limits
Lithium battery.
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
P
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
P
14.11
Optocouplers
No optocouplers
N
Optocouplers comply with Cl. 8
N
N
14.12
Surge suppression varistors
No such component
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
Report No. SF201200115 Page 15 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
15
TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Not connect to mains.
N
Overloading of plugs or appliance inlets
prevented if the apparatus has mains socket
outlets
prevented if the apparatus has mains socket
outlets
N
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
N
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No such component.
N
15.1.3
Output terminals of a.c. adaptors or similar
devices not compatible with household mains
socket-outlets
devices not compatible with household mains
socket-outlets
N
15.2
Provision for protective earthing
N
Accessible
conductive
parts
of
Class I
equipment reliably connected to earth terminal,
within equipment
within equipment
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance test: < 0,1
Ω
at 25 A .............. :
N
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
No such component.
N
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2
Reliable connection of non-detachable cords:
N
Not soldered to conductors of a printed circuit
board
board
N
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N
Wire secured by additional means to the
conductor
conductor
N
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N
Report No. SF201200115 Page 16 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N
15.3.5
Terminals allow connection of appropriate
cross-sectional area of conductors, for the rated
current of the equipment
cross-sectional area of conductors, for the rated
current of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N
Terminals designed to avoid conductor slipping
out when tightened or loosened
out when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N
Terminals located and shielded: test with 8 mm
strand
strand
N
15.4
Devices forming a part of the mains plug
Not such device.
N
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
N
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ........................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ........................................................ :
Not connect to mains
N
Non-detachable
cords
for
Class I
have
green/yellow core for protective earth
N
16.2
Mains
cords
conductors
have
adequate
cross-sectional
area
for
rated
current
consumption of the equipment
N