JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate ▷ View online

Report No. SF201200115                                                                                                        Page 5 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
 
Instructions 
for 
permanently 
connected 
equipment 
 
 
 
 
 
HAZARDOUS RADIATION 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
 
6.1 
EN 60065 
µSv/h (0,1mR/h) 
 
6.2 
Laser radiation, emission limits to IEC 60825-1  :   
 
Emission limits under fault conditions ................ :   
 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
7.1 
Temperature  rises  not  exceeding  specified 
values, no operation of fuse links 
see appended table 7.1 
7.1.1 
Temperature rise of accessible parts 
see appended table 7.1 
7.1.2 
Temperature  rise  of  parts  providing  electrical 
insulation 
 
7.1.3 
Temperature rise of parts acting as a support or 
as a mechanical barrier 
 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
see appended table 7.1 
7.2 
Softening  temperature  of  insulating  material 
supporting  parts  conductively  connected  to  the 
mains carrying a current > 0,2 A at least 150
 o
 
 
 
 
CONSTRUCTIONAL 
REQUIREMENTS 
WITH 
REGARD 
TO 
THE 
PROTECTION AGAINST ELECTRIC SHOCK 
8.1 
Conductive  parts  covered  by  lacquer,  paper, 
untreated  textile  oxide  films  and  beads  etc. 
considered to be bare 
 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hazardous live parts. 
8.4 
No risk of electric shock following the removal of 
a cover which can be removed by hand 
No hazard after the removing 
of battery cover. 
8.5 
Class I equipment 
Not class I equipment 
 
Basic  insulation  between  hazardous  live  parts 
and earthed accessible parts 
 
Report No. SF201200115                                                                                                        Page 6 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
 
Resistors  bridging  basic  insulation  complying 
with 14.1 a) 
 
8.6 
Class II  equipment  and  Class II  constructions 
within Class I equipment 
Not class II equipment 
 
Reinforced  or  double  insulation  between 
hazardous live parts and accessible parts 
 
 
Components  bridging  reinforced  or  double 
insulation complying with 14.1 a) or 14.3 
 
 
Basic  and  supplementary  insulation  each  being 
bridged by a capacitor complying with 14.2.1 a) 
 
 
Reinforced  or  double  insulation  being  bridged 
with  2  capacitors  in  series  complying  with 
14.2.1 a) 
 
 
Reinforced  or  double  insulation  being  bridged 
with a single capacitor complying with 14.2.1 b) 
 
 
Basic 
insulation 
bridged 
by 
components 
complying with 14.3.4.3 
 
8.7 
This clause is void 
 
--- 
8.8 
Basic  or  supplementary  insulation  > 0,4 mm 
(mm)  .................................................................... : 
 
 
Reinforced insulation > 0,4 mm (mm) ................ :  No such insulation 
 
Thin  sheet  insulation  (excluding  non-separable 
thin sheet insulation. See 8.22) 
No such insulation 
 
Basic  or  supplementary  insulation,  at  least  two 
layers, each meeting 10.3 
 
 
Basic  or  supplementary  insulation,  three  layers 
any two of which meet 10.3 
 
 
Reinforced  insulation,  two  layers  each  of  which 
meet 10.3 
 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
No 
hazardous 
live 
conductors. 
 
Adequate insulation between internal hazardous 
live  parts  and  conductors  connected  to 
accessible parts 
 
8.10 
Double 
insulation 
between 
conductors 
connected to the mains and accessible parts. 
Double  insulation  between  internal    hazardous 
live  parts  and  conductors  connected  to 
accessible parts
Not class  Ⅱ  apparatus. 
8.11 
Detaching of wires 
 
Report No. SF201200115                                                                                                        Page 7 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
 
No  undue  reduction  of  creepages  or  clearance 
distances if wires become detached 
 
 
Vibration test carried out ..................................... :  No 
8.12 
This clause is void 
 
--- 
8.13 
Adequate  fastening  of  windows,  lenses,  lamp 
covers etc. (pull test 20 N for 10 s) 
No hazardous live parts. 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
No hazardous live parts. 
8.15 
No  risk  of  damage  to  the  insulation  of  internal 
wiring due to hot parts or sharp edges 
 
8.16 
Only special supply equipment can be used 
 
8.17 
Insulated  winding  wire  without  additional 
interleaved insulation 
No such component. 
8.18 
Endurance test as required by 8.17 
 
8.19 
Disconnection from the mains 
Not connect to the mains. 
8.19.1 
Disconnect device 
 
 
All-pole  switch  or  circuit  breaker  with  >3mm 
contact separation 
 
8.19.2 
Mains switch ON indication 
 
8.20 
Switch not fitted in the mains cord 
No mains cord. 
8.21 
Bridging components comply with clause 14 
No such component 
8.22 
Non-separable thin sheet material 
 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation   
No  voltages  >1000  V  ac  or 
>1500 V dc . 
9.1.1.1 
a) Open circuit voltages 
Supplied  by  12V  DC,  no 
hazardous  voltage  generate 
circuit. 
 
b)  Touch  current  measured  from  terminal 
devices using the network in annex D  ............... : 
U1 
U2 
 
c) Discharge not exceeding 45 
μC 
 
 
d) Energy of discharge not exceeding 350 mJ 
 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No  hazardous  live  shafts  of  knobs,  handles  or 
levers 
 
Report No. SF201200115                                                                                                        Page 8 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
9.1.3 
Ventilation  holes  and  other  holes  tested  by 
means of 4 mm x 100 mm test pin 
No hazardous live parts. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
No hazardous live parts. 
 
Terminal  devices  tested  with  1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
No hazardous live parts. 
9.1.5 
Pre-set  controls  tested  with  2.5 mm x 100 mm 
test pin (10 N); test probe C of IEC 61032 
No such component 
9.1.6 
No  shock  hazard  due  to  stored  charge  on 
withdrawal  of  the  mains  plug;  voltage  (V)  after 
2 s ........................................................................ : 
Not connect to mains. 
 
If C is not greater than 0,1 
μF no test needed 
 
9.1.7 
a)  Enclosure  sufficiently  resistant  to  external 
force 
No hazardous live parts. 
 
  Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
 
 
c)  30 mm  diameter  test  tool  for  5 s  (100  or 
250 N) .................................................................. : 
 
9.2 
No hazard after removing a cover by hand 
Removing of battery cover. 
 
 
 
10 
INSULATION REQUIREMENTS 
10.1 
Insulation  resistance  (M
Ω)  at  least  2 MΩ  min. 
after  surge  test  for  basic  and  4 M
Ω  min.  for 
reinforced insulation  ........................................... : 
Not connect to mains. 
10.2 
Humidity treatment 48 h or 120 h ....................... :  48 h 
120 h 
10.3 
Insulation  resistance  and  dielectric  strength 
between mains teminals 
 
 
Insulation  Resistance  and  dielectric  strength 
across  BASIC  or  SUPPLEMENTARY  insulation 
(Class 1) 
 
 
Insulation  resistance  and  dielectric  strength 
across REINFORCED insulation (Class II) 
 
 
 
 
11 
FAULT CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
No softening solder 