JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. SF201200115 Page 5 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Instructions
for
permanently
connected
equipment
N
6
HAZARDOUS RADIATION
N
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N
6.1
EN 60065
µSv/h (0,1mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825-1 :
N
Emission limits under fault conditions ................ :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified
values, no operation of fuse links
values, no operation of fuse links
see appended table 7.1
P
7.1.1
Temperature rise of accessible parts
see appended table 7.1
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
N
7.1.3
Temperature rise of parts acting as a support or
as a mechanical barrier
as a mechanical barrier
N
7.1.4
Temperature rise of windings
N
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
see appended table 7.1
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
N
8
CONSTRUCTIONAL
REQUIREMENTS
WITH
REGARD
TO
THE
PROTECTION AGAINST ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hazardous live parts.
N
8.4
No risk of electric shock following the removal of
a cover which can be removed by hand
a cover which can be removed by hand
No hazard after the removing
of battery cover.
of battery cover.
P
8.5
Class I equipment
Not class I equipment
N
Basic insulation between hazardous live parts
and earthed accessible parts
and earthed accessible parts
N
Report No. SF201200115 Page 6 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Resistors bridging basic insulation complying
with 14.1 a)
with 14.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Not class II equipment
N
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
N
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
N
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged
with 2 capacitors in series complying with
14.2.1 a)
with 2 capacitors in series complying with
14.2.1 a)
N
Reinforced or double insulation being bridged
with a single capacitor complying with 14.2.1 b)
with a single capacitor complying with 14.2.1 b)
N
Basic
insulation
bridged
by
components
complying with 14.3.4.3
N
8.7
This clause is void
---
8.8
Basic or supplementary insulation > 0,4 mm
(mm) .................................................................... :
(mm) .................................................................... :
N
Reinforced insulation > 0,4 mm (mm) ................ : No such insulation
N
Thin sheet insulation (excluding non-separable
thin sheet insulation. See 8.22)
thin sheet insulation. See 8.22)
No such insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
No
hazardous
live
conductors.
N
Adequate insulation between internal hazardous
live parts and conductors connected to
accessible parts
live parts and conductors connected to
accessible parts
N
8.10
Double
insulation
between
conductors
connected to the mains and accessible parts.
Double insulation between internal hazardous
live parts and conductors connected to
accessible parts
live parts and conductors connected to
accessible parts
.
Not class Ⅱ apparatus.
N
8.11
Detaching of wires
N
Report No. SF201200115 Page 7 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
N
Vibration test carried out ..................................... : No
N
8.12
This clause is void
---
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No hazardous live parts.
N
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
No hazardous live parts.
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No such component.
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
Not connect to the mains.
N
8.19.1
Disconnect device
N
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
N
8.19.2
Mains switch ON indication
N
8.20
Switch not fitted in the mains cord
No mains cord.
N
8.21
Bridging components comply with clause 14
No such component
N
8.22
Non-separable thin sheet material
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages >1000 V ac or
>1500 V dc .
>1500 V dc .
P
9.1.1.1
a) Open circuit voltages
Supplied by 12V DC, no
hazardous voltage generate
circuit.
hazardous voltage generate
circuit.
P
b) Touch current measured from terminal
devices using the network in annex D ............... :
devices using the network in annex D ............... :
U1
U2
U2
N
c) Discharge not exceeding 45
μC
N
d) Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
N
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
N
Report No. SF201200115 Page 8 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
9.1.3
Ventilation holes and other holes tested by
means of 4 mm x 100 mm test pin
means of 4 mm x 100 mm test pin
No hazardous live parts.
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
No hazardous live parts.
N
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
No hazardous live parts.
N
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm
test pin (10 N); test probe C of IEC 61032
test pin (10 N); test probe C of IEC 61032
No such component
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s ........................................................................ :
withdrawal of the mains plug; voltage (V) after
2 s ........................................................................ :
Not connect to mains.
N
If C is not greater than 0,1
μF no test needed
N
9.1.7
a) Enclosure sufficiently resistant to external
force
force
No hazardous live parts.
N
Test probe 11 of IEC 61032 for 10 s (50 N)
N
b) Test hook of fig. 4 for 10 s (20 N)
N
c) 30 mm diameter test tool for 5 s (100 or
250 N) .................................................................. :
250 N) .................................................................. :
N
9.2
No hazard after removing a cover by hand
Removing of battery cover.
P
10
INSULATION REQUIREMENTS
N
10.1
Insulation resistance (M
Ω) at least 2 MΩ min.
after surge test for basic and 4 M
Ω min. for
reinforced insulation ........................................... :
Not connect to mains.
N
10.2
Humidity treatment 48 h or 120 h ....................... : 48 h
120 h
N
10.3
Insulation resistance and dielectric strength
between mains teminals
between mains teminals
N
Insulation Resistance and dielectric strength
across BASIC or SUPPLEMENTARY insulation
(Class 1)
across BASIC or SUPPLEMENTARY insulation
(Class 1)
N
Insulation resistance and dielectric strength
across REINFORCED insulation (Class II)
across REINFORCED insulation (Class II)
N
11
FAULT CONDITIONS
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
No softening solder
P
Click on the first or last page to see other JEMBE WIRELESS (serv.man2) service manuals if exist.