JBL JEMBE WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. SF201200115 Page 17 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
16.3
a) Flexible cords not complying with 16.1, used
for interconnections between separate units of
equipment used in combination and carrying
hazardous
for interconnections between separate units of
equipment used in combination and carrying
hazardous
live
voltages,
have
adequate
dielectric strength
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas
to avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas
to avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible
cord
cord
N
For mains cords of Class I equipment,
hazardous live conductors become taut before
earth conductor
hazardous live conductors become taut before
earth conductor
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or
movement in use
damage to the cord during assembly or
movement in use
N
16.7
Transportable
musical
instruments
and
amplifiers fitted with detachable cord set with
appliance inlet to IEC 60320-1
appliance inlet to IEC 60320-1
N
Transportable
musical
instruments
and
amplifiers fitted with detachable cord sets or with
means of stowage to protect the cord
means of stowage to protect the cord
N
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
P
17.1
Torque test to table 20:
P
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
Screws of fixing enclosure.
P
17.2
Correct introduction into female threads in
non-metallic material
non-metallic material
P
17.3
Cover fixing screws: captive
No hazardous live parts.
N
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
N
17.4
No loosening of conductive parts carrying a
current > 0,2 A
current > 0,2 A
N
Report No. SF201200115 Page 18 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
Connector with resiliently
metallic parts.
metallic parts.
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals
not consolidated by solder
carrying a current > 0,2 A with screw terminals
not consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N
17.8
Fixing devices for detachable legs or stands
provided
provided
N
17.9
N
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION
AGAINST THE EFFECTS OF IMPLOSION
AGAINST THE EFFECTS OF IMPLOSION
N
Picture tube separately approved to IEC 61965: Yes / No
N
Picture tube separately approved to 18.1 ........... Yes / No
N
18.1
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used
with protective screen
with protective screen
N
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test
(steel ball): 6
(steel ball): 6
N
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ............. : 1.01 kg
N
Apparatus intended to be fastened in place
–
suitable instructions
No
N
19.1
Test on a plane, inclined at 10
o
to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
100 N force, or 13% of weight, applied
horizontally to point of least stability.
horizontally to point of least stability.
N
19.4
Edges or corners not hazardous
Smooth surface and corners
P
Report No. SF201200115 Page 19 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m
exceeding 0,1 m
² or maximum dimension
> 450 mm, pass the test of 19.5.1
N
19.6
Wall or ceiling mountings adequate
N
20
RESISTANCE TO FIRE
P
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10
with openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10
with openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
20.1
N
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
N
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure,
> 4 Kv or leaving an internal fire enclosure,
or
located within the areas mentioned in Table 21,
not contributing to the spread of fire
P
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c.
meets V-1 or better to IEC60707, unless used in
a fire enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c.
meets V-1 or better to IEC60707, unless used in
a fire enclosure
Supply voltage: DC 12V
No potential ignition source.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
>400 V (peak) a.c. or d.c. meets V-0 to
IEC 60707
available power exceeds 15 W at a voltage
>400 V (peak) a.c. or d.c. meets V-0 to
IEC 60707
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source
than the distances in Table 21 comply with the
relevant flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source
than the distances in Table 21 comply with the
relevant flammability category in Table 21
No potential ignition source
in the equipment.
in the equipment.
N
Components and parts as above but shielded
from a potential ignition source, with the barrier
area in accordance with Table 21 and fig. 13
from a potential ignition source, with the barrier
area in accordance with Table 21 and fig. 13
N
Apparatus with voltages >4kV under normal
operating conditions and distances to the
enclosure exceed those specified Table 21,
flammability classification HB40 or better is
required for the enclosure.
operating conditions and distances to the
enclosure exceed those specified Table 21,
flammability classification HB40 or better is
required for the enclosure.
N
20.2
Fire enclosure
N
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a
fire enclosure to V-1
voltage > 4 kV (peak) a.c. or d.c. contained in a
fire enclosure to V-1
N
Report No. SF201200115 Page 20 of 32
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20.2.2
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N
Click on the first or last page to see other JEMBE WIRELESS (serv.man2) service manuals if exist.