Report No. SF201200115                                                                                                        Page 17 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
16.3 
a) Flexible cords not complying with 16.1, used 
for  interconnections  between  separate  units  of 
equipment  used  in  combination  and  carrying 
hazardous 
live 
voltages, 
have 
adequate 
dielectric strength 
 
 
 
b)  Flexible  cords  not  complying  with  16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
 
16.4 
Flexible  cords  used  for  connection  between 
equipment have adequate cross-sectional areas 
to avoid temperature rise under normal and fault 
conditions 
 
16.5 
Adequate strain relief on external flexible cords 
 
 
Not possible to push cord back into equipment 
 
 
Strain  relief  device  unlikely  to  damage  flexible 
cord 
 
 
For  mains  cords  of  Class I  equipment, 
hazardous  live  conductors  become  taut  before 
earth conductor 
 
16.6 
Apertures  for  external  flexible  cord:  no  risk  of 
damage  to  the  cord  during  assembly  or 
movement in use 
 
16.7 
Transportable 
musical 
instruments 
and 
amplifiers  fitted  with  detachable  cord  set  with 
appliance inlet to IEC 60320-1 
 
 
Transportable 
musical 
instruments 
and 
amplifiers fitted with detachable cord sets or with 
means of stowage to protect the cord 
 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
17.1 
Torque test to table 20: 
 
 
- screws into metal: 5 times 
 
 
- screws into non-metallic material: 10 times 
Screws of fixing enclosure. 
17.2 
Correct  introduction  into  female  threads  in 
non-metallic material 
 
17.3 
Cover fixing screws: captive 
No hazardous live parts. 
 
Non-captive  fixing  screws:  no  hazard  when 
replaced by a screw whose length is 10 times its 
diameter 
 
17.4 
No  loosening  of  conductive  parts  carrying  a 
current > 0,2 A 
 
Report No. SF201200115                                                                                                        Page 18 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
17.5 
Contact pressure not transmitted through plastic 
other  than  ceramic  for  connections  carrying  a 
current > 0,2 A 
Connector  with  resiliently 
metallic parts. 
17.6 
Stranded  conductors  of  flexible  supply  cords 
carrying  a  current  > 0,2 A  with  screw  terminals 
not consolidated by solder 
 
17.7 
Cover  fixing  devices  other  than  screws  have 
adequate  strength  and  their  positioning  is 
unambiguous 
 
17.8 
Fixing  devices  for  detachable  legs  or  stands 
provided 
 
17.9 
 
 
 
 
18 
MECHANICAL  STRENGTH  OF  PICTURE  TUBES  AND  PROTECTION 
AGAINST THE EFFECTS OF IMPLOSION 
 
Picture tube separately approved to IEC 61965:  Yes / No 
 
Picture tube separately approved to 18.1 ...........   Yes / No 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically  protected  tubes  > 16 cm  used 
with protective screen 
 
 
Protective  film  as  part  of  implosion  protection: 
edges covered by enclosure 
 
18.2 
Intrinsically protected tubes: tests on 12 samples   
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples  subject  to  mechanical  strength  test 
(steel ball): 6 
 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg ............. :  1.01 kg 
 
Apparatus  intended  to  be  fastened  in  place 
– 
suitable instructions 
No 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal   
19.2 
100 N force applied vertically downwards 
 
19.3 
100  N  force,  or  13%  of  weight,  applied 
horizontally to point of least stability. 
 
19.4 
Edges or corners not hazardous 
Smooth surface and corners 
Report No. SF201200115                                                                                                        Page 19 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
19.5 
Glass  surfaces  (exc.laminated)  with  an  area 
exceeding  0,1 m
²  or  maximum  dimension 
> 450 mm, pass the test of 19.5.1 
 
19.6 
Wall or ceiling mountings adequate 
 
 
 
 
20 
RESISTANCE TO FIRE 
20.1 
Electrical components and mechanical parts 
 
a)  Exemption  for  components  contained  in  an 
enclosure  of  material  V-0  to  IEC  60695-11-10 
with openings not exceeding 1 mm in width 
 
 
b) Exemption for small components as defined in 
20.1 
 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
 
20.1.2 
Insulation  of  internal  wiring  working  at  voltages 
> 4 Kv  or  leaving  an  internal  fire  enclosure,
  or 
located within the areas mentioned in Table 21,
 
not contributing to the spread of fire 
 
20.1.3 
Material  of  printed  circuit  boards  on  which  the 
available  power  exceeds  15 W  at  a  voltage 
between  50 V  and  400 V  (peak)  a.c.  or  d.c. 
meets V-1 or better to IEC60707, unless used in 
a fire enclosure 
Supply voltage: DC 12V 
No potential ignition source. 
 
Material  of  printed  circuit  boards  on  which  the 
available  power  exceeds  15 W  at  a  voltage 
>400 V  (peak)  a.c.  or  d.c.  meets  V-0  to 
IEC 60707 
 
20.1.4 
Components  and  parts  not  covered  by  20.1.1, 
20.1.2  and  20.1.3  (other  than  fire  enclosures) 
mounted  nearer  to  a  potential  ignition  source 
than  the  distances  in  Table 21  comply  with  the 
relevant flammability category in Table 21 
No  potential  ignition  source 
in the equipment. 
 
Components  and  parts  as  above  but  shielded 
from  a  potential  ignition  source,  with  the  barrier 
area in accordance with Table 21 and fig. 13 
 
 
Apparatus  with  voltages  >4kV  under  normal 
operating  conditions  and  distances  to  the 
enclosure  exceed  those  specified  Table  21, 
flammability  classification  HB40  or  better  is 
required for the enclosure. 
 
20.2 
Fire enclosure 
 
20.2.1 
Potential  ignition  sources  with  open  circuit 
voltage > 4 kV (peak) a.c. or d.c. contained in a 
fire enclosure to V-1 
 
Report No. SF201200115                                                                                                        Page 20 of 32 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
20.2.2 
 
20.2.3 
Requirements  of  20.2.1  and  20.2.2  met  by  an 
internal fire enclosure 
 
 
Page of 32
Display