JBL ES 150P EMC - CB Certificate ▷ View online

 
Page 14 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 P 
14.6 
Switches 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
V-0 compliance with annex G, G.1.1 
and 
Peak inrush rating of switch 
Measured/calculated inrush…………………………: 
Mains switch 
 
 
 
 
 
128A 
39A (Calculated) 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 N/A 
 
Switch controlling = 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
action independent of speed of actuation 
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d), l) and m) not attaining 
excessive temperatures in use 
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
 N/A 
 
Socket outlet current marking correct 
 
N/A 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
 
Page 15 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
14.9 
Motors 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 Dielectric 
strength 
test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
 N/A 
14.10 
Batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits 
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 Battery 
drop 
test 
 
N/A 
14.11 
Optocouplers 
 
Optocouplers comply with Cl. 8 
 
N/A 
 
 N/A 
14.12 
Surge suppression varistors 
 
Comply with IEC 61051-2 
 
N/A 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus 
 N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 N/A 
 
 
Page 16 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
15 TERMINALS 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the  cross-
sectional area specified in 16.2 for external cords 
Mains plug, appliance inlet 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
 
 
No risk of insertion into audio or video-outlets 
marked with the symbol of 5.2 
 N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
 N/A 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
 N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N/A 
 
Earthing connection of parts removable by hand. 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0.1 
Ω at 25 A ...................:   N/A 
15.3 
Terminals for external flexible cords and for permanent connection to the mains supply 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
Not soldered to conductors of a printed circuit board Appliance inlet 
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 N/A 
 
Wire secured by additional means to the conductor   
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
 N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means 
 N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws 
 N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment 
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16   
N/A 
 
Page 17 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided 
 N/A 
15.3.8 
Terminals carrying a current more than 0.2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 N/A 
15.3.9 
Termination of non-detachable cords/wires 
terminated near to each other 
 N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
 N/A 
15.4 
Devices forming a part of the mains plug 
15.4.1 
No undue strain on mains socket-outlets 
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N/A 
15.4.3 
Device has adequate mechanical strength  
(tests a, b, c) 
 N/A 
 
 
16 EXTERNAL 
FLEXIBLE 
CORDS 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ...........................................................: 
See Remark 1 under Summary 
of testing
 on page 3. 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth 
 N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
See Remark 1 and Remark 2 
under Summary of testing on 
page 3. 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)
 N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 N/A 
Page of 57