DOWNLOAD JBL ES 150P Service Manual ↓ Size: 4.46 MB | Pages: 57 in PDF or view online for FREE

Model
ES 150P
Pages
57
Size
4.46 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
es-150p.pdf
Date

JBL ES 150P EMC - CB Certificate ▷ View online

 
Page 34 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
National differences  Germany 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CENELEC / DE  06  II
 
 
6.1
 
The following requirement applies: 
For the operation of any cathode ray tube 
intended for the display of visual images 
operating at an acceleration voltage exceeding 40 
kV, authorization is required, or application of 
type approval (Bauartzulassung) and marking. 
Justification
 N/A 
 
 
Page 35 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
National differences  Denmark 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CB Bulletin 112A / DK  06 II
 
 
2.6.1 
The following is added: 
Certain types of CLASS I apparatus, see 15.1.1, may 
be provided with a plug not establishing earthing 
continuity when inserted in Danish socket-outlets 
Justification: 
Heavy Current Regulations, Section 107 
 N/A 
15.1.1 
To the first paragraph the following is added: 
In Denmark, supply cords of single phase appliances 
having a rated current not exceeding 13 A shall be 
provided with a plug according to the Heavy Current 
Regulations Section 107-2-D1. 
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used in 
locations where protection against indirect contact is 
required according to the wiring rules shall be provided 
with a plug in accordance with the Heavy Current 
Regulations Section 107-2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added: 
Socket outlets intended for provided power to CLASS II 
apparatus with a rated current of 2.5 A shall have the 
following dimensions: 
 
 
Dimensions in mm 
 
Other dimensions shall be in compliance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DKA 1-3 for portable socket-outlets. 
Shutters are not required. 
To the third paragraph the following is added: 
Mains socket-outlets with earthing contact shall be in 
compliance with the Heavy Current Regulations, 
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a 
or DK 1-7a. 
Justification
Heavy Current Regulations, Section 107 
Only 1
st
 paragraph 
(Class II appliances and no 
socket-outlets) 
 
 
 
Page 36 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
National differences  Ireland 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CENELEC / IE  06 II
 
 
 
Apparatus which is fitted with a flexible cable or 
cord shall be provided with a 13 A plug in 
accordance with Statutory Instrument 525:97, “13 
A  Plugs and Conversion Adapters for Domestic 
Use Regulations:1997. 
Justification: 
SI 525: 1997 
See Remark 1 under Summary 
of testing
 on page 3. 
 
 
 
National differences  United Kingdom 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CB Bulletin 112A / GB  06 II
 
 
15.1.1 
Apparatus which is fitted with a flexible cable or 
cord and is designed to be connected to a mains 
socket conforming to BS 1363 by means of that 
flexible cable or cord and plug shall be fitted with 
a ”standard plug” in accordance with Statutory 
Instrument 1768: 1994: The Plugs and Sockets 
etc. (Safety) Regulations 1994, unless exempted 
by those Regulations. 
NOTE ”Standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved 
conversion plug. 
Justification
: SI 1768: 1994 
See Remark 1 under Summary 
of testing
 on page 3. 
 
 
 
National differences  Italy 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CENELEC / IT  06  II
 
 
5.1 
Additional markings on the outside of the TV 
receiver in Italian language 
 
N/A 
 
User instructions in Italian language including a 
conformity declaration 
 N/A 
 
Certification number on the back cover 
 
N/A 
 
Page 37 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
National differences  Norway 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CB Bulletin 112A/ NO  06 II
 
 
13.3.1 
To the second paragraph the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification: 
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 P 
15.1.1 Mains 
socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as fas as a Applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2.5 A 250 V two-pole socket-outlets for 
electronic apparatus shall comply with the 
enclosed Standard Sheet I. 
 
Justification: 
Act of 24 May 1929 relating to supervision of 
electrical installation (TEA 1929/FEL 1998). 
 N/A 
Page of 57
Display