JBL ES 150P EMC - CB Certificate ▷ View online
Page 26 of 44
Report No. 707082
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14
TABLE: list of critical components and materials
P
Object/Part No.
Manufacturer
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
1
)
Mains
transformer
transformer
Zhong Shan Yi Qi
electronic parts
Co., Ltd
150-R0905504-E
230V / 50Hz
IEC 60065
—
Thermal link
Aupo Electronics
Co., Ltd
A4
5A 250V 130
°C
IEC 60691
Plastic cover
(core insulation
in transformer)
(core insulation
in transformer)
Zhongshan Napu
Engineering Plastic
PP-FR Thickness
0.9mm
tested acc to
Annex G.1.1
Annex G.1.4
IEC60065
(HB75)
Tested as part
of the
application
Appliance inlet
Pronic
PST-101
10A 250V
IEC 60320
Mains switch
CHILY
3024
16(4)A, 8/128A
250V Class II
IEC 61058-1
IEC60065:2001 Sub-
clause 14.6.1a)
Mains fuse F1
Walter
TSD
T2.5AL 250V
IEC 60127
Mains fuse
holder
holder
Shin Chin
R3-45A
94V-0
IEC 60707
HB75
—
Insulation plate
in Line filter L01
in Line filter L01
Lian Cheng
PCB 1.0T
94V-0
IEC 60707
HB75
—
Mains Cordset:
Plug
Cord
Connector
Cord
Connector
Well Shin
WS-019
H05VV-F
WS-002E
16A 250V
2 x 0.75mm
2
10A 250V
CEE7
IEC 60227
IEC 60320
IEC 60320
Mains Cordset
for Korea
Plug
Cord
Connector
for Korea
Plug
Cord
Connector
Well Shin
WS-019-A
VCTFK
WS-002E
3A 250V
2 x 0.75mm
2
10A 250V
KS C8305
KS C3304
KS C3304
IEC 60320
Mains capacitor
C01, C02
(across the line)
C01, C02
(across the line)
Europtronic MPX 0.33
μF 275V
X2
IEC 60384-14
2
nd
edition
Mains capacitor
C03, C04
(single
connected to
accessible
parts)
C03, C04
(single
connected to
accessible
parts)
Welson Industrial
WD
1nF 250V
Y1
IEC 60384-14
2
nd
edition
Amplifier
Plastic Cover
Plastic Cover
Shr Hua
PA-765
(ABS)
94V-0
Thickness used: 3.0mm
IEC 60707
HB75
—
Pre PCB
Luen Tai
A126
Main PCB
EMC PCB
EMC PCB
Cheng Ho Ind.
(Jianhe)
4B-1
Class D PCB
Hsiang Kuo
76V0A
94V-0
IEC 60707
V-1
—
Page 27 of 44
Report No. 707082
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Heat
shrinkable tube
shrinkable tube
Dongguan Quantai
Electronics
T-2 VW-1
IEC
60707
Complies with
—
Alt. heat
shrinkable tube
shrinkable tube
Shenzhen
Changyuan
Electronic Material
102 HB75
1
) An asterisk indicates a mark which assures the agreed level of surveillance.
2
) Description to include adjacent markings for critical fuse/s.
Group differences
IEC 60065:2001 + A1
CB Bulletin 112A / GRP 06 II
Contents
Add the following annexes:
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures
from headphones or earphones
from headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
P
4.1.1
Replace
the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
50333
.
P
5.1.i)
Add
the following note:
NOTE For RATED POWER CONSUMPTION
mesurements of TVs reference is made to EN 60107.
mesurements of TVs reference is made to EN 60107.
N/A
Page 28 of 44
Report No. 707082
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6.1
Replace
the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
N/A
13.3.1
Delete
note 4.
P
14
Delete
note 4 and note 5.
P
15.1.1
Delete
notes 1 and 2.
P
15.2
Delete
note 2.
P
16.1
Delete
note 1.
P
16.2
Delete
the note.
P
20
Delete
note 2.
P
Page 29 of 44
Report No. 707082
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Annex B
Replace
note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
N/A
Annex G
Delete
the note.
P
Annex J.2 Delete the notes of Table J.1.
N/A
Annex N
Add
after the introduction:
For ROUTINE TEST reference is made to EN
50333.
50333.
P
Bibliography
Add
the following standards:
EN 60332-1: 2000, Sound system equipement: Headphones and earphones
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for ”one package equipment”.
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for ”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipement: Headphones and
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology
and limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology
and limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
Add the following notes for the standards indicated:
IEC 60130
NOTE
Parts 9 and 17: 1998 are harmonized as Ens (not modified).
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56 NOTE
Harmonized as EN 60335-2-56: 1997 (not modified).
IEC 60335-2-82 NOTE Harmonized as EN 60335-2-82: 2000 (not modified).
IEC 60695
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1
NOTE
Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4
NOTE Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6
NOTE Harmonized as EN 61558-2-6: 1997 (not modified).
P