Page 26 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
14 
TABLE: list of critical components and materials 
Object/Part No. 
Manufacturer 
/Trademark 
Type/Model 
Technical Data
2
Standard 
Mark(s) of 
Conformity
1
Mains 
transformer 
Zhong Shan Yi Qi 
electronic parts 
Co., Ltd 
150-R0905504-E
230V / 50Hz 
IEC 60065 
— 
Thermal link 
Aupo Electronics 
Co., Ltd 
A4 
5A 250V 130
°C 
IEC 60691 
 
Plastic cover 
(core insulation 
in transformer) 
Zhongshan Napu 
Engineering Plastic
PP-FR Thickness 
0.9mm
tested acc to 
Annex G.1.1 
Annex G.1.4 
IEC60065 
(HB75) 
Tested as part 
of the 
application 
Appliance inlet 
Pronic 
PST-101 
10A 250V 
IEC 60320 
 
Mains switch 
CHILY 
3024 
16(4)A, 8/128A 
250V Class II 
IEC 61058-1 
IEC60065:2001 Sub-
clause 14.6.1a)
 
 
Mains fuse F1 
Walter 
TSD 
T2.5AL 250V 
IEC 60127 
 
Mains fuse 
holder 
Shin Chin 
R3-45A 
94V-0 
IEC 60707 
HB75 
— 
Insulation plate 
in Line filter L01 
Lian Cheng 
PCB 1.0T 
94V-0 
IEC 60707 
HB75 
— 
Mains Cordset: 
Plug 
Cord 
Connector 
Well Shin 
 
 
WS-019 
H05VV-F 
WS-002E 
 
16A 250V 
2 x 0.75mm
2
 
10A 250V 
 
CEE7 
IEC 60227 
IEC 60320 
 
 
 
 
Mains Cordset 
for Korea 
Plug 
Cord 
Connector 
Well Shin 
 
 
 
WS-019-A 
VCTFK 
WS-002E 
 
 
3A   250V 
2 x 0.75mm
2
 
10A 250V 
 
 
KS C8305 
KS C3304 
IEC 60320 
 
 
 
 
 
Mains capacitor 
C01, C02           
(across the line) 
Europtronic MPX 0.33
μF 275V   
X2 
IEC 60384-14 
2
nd
 edition 
 
Mains capacitor 
C03, C04       
(single 
connected  to 
accessible 
parts) 
Welson Industrial 
WD 
1nF 250V   
Y1 
IEC 60384-14 
2
nd
 edition 
 
Amplifier 
Plastic Cover 
Shr Hua 
PA-765  
(ABS) 
94V-0 
Thickness used: 3.0mm
IEC 60707 
HB75 
— 
Pre  PCB 
Luen Tai 
A126 
Main PCB 
EMC PCB 
Cheng Ho Ind. 
(Jianhe) 
4B-1 
Class D PCB 
Hsiang Kuo 
76V0A 
94V-0 
 
IEC 60707 
V-1 
— 
 
Page 27 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
Heat 
shrinkable tube 
Dongguan Quantai 
Electronics 
T-2 VW-1 
IEC 
60707 
Complies with  
— 
Alt. heat 
shrinkable tube 
Shenzhen 
Changyuan 
Electronic Material
102  HB75 
 
1
) An asterisk indicates a mark which assures the agreed level of surveillance.  
2
) Description to include adjacent markings for critical fuse/s. 
 
 
 
 
 
 
 
Group differences  
IEC 60065:2001 + A1       
                                                                
CB Bulletin 112A / GRP 06  II
 
 
Contents 
Add the following annexes: 
Annex ZB (nominative) Special national conditions 
Annex ZC (informative) A-deviations  
3.1 
Add the following indent at the end of the list 
Exposure to excessive sound pressures 
from headphones or earphones 
NOTE  A new method of measurement is described in 
EN 50332-1, Sound system equipment: Headphones 
and earphones associated 
with portable audio equipment – Maximum sound 
pressure level measurement methodology and limit 
considerations – Part 1: General 
method for ”one package equipment”, and in EN 
50332-2, Sound system equipment: Headphones and 
earphones associated with 
portable audio equipment – Maximum sound pressure 
level measurement methodology and limit 
considerations – Part 2: Guidelines to 
associate sets with headphones coming from different 
manufacturers. 
 P 
4.1.1 
Replace 
the text of the note by: 
NOTE For ROUTINE TEST reference is made to EN 
50333
 P 
5.1.i) 
Add 
the following note: 
NOTE    For RATED POWER CONSUMPTION 
mesurements of TVs reference is made to EN 60107. 
 N/A 
 
Page 28 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
6.1 
Replace 
the entire subclause by: 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under fault 
conditions. 
Compliance is checked by measurement under 
the following conditions: 
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, 
by any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made. 
 N/A 
13.3.1 
Delete 
note 4. 
 P 
14  
Delete 
note 4 and note 5. 
 
15.1.1 
Delete
 notes 1 and 2. 
 P 
15.2 
Delete
 note 2. 
 P 
16.1 
Delete
 note 1. 
 P 
16.2 
Delete
 the note. 
 P 
20 
Delete
 note 2. 
 P 
 
Page 29 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
Annex B 
Replace 
note 1 by: 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
 N/A 
Annex G 
Delete
 the note. 
 P 
Annex J.2  Delete the notes of Table J.1. 
 N/A 
Annex N 
Add 
after the introduction: 
For ROUTINE TEST reference is made to EN 
50333. 
 P 
Bibliography 
 
Add 
the following standards: 
EN 60332-1: 2000, Sound system equipement: Headphones and earphones 
associated with portable audio equipment – 
Maximum sound pressure level measurement methodology and limit 
considerations – Part 1: General method for ”one package equipment”. 
PrEN 50332-2 (uder consideration), Sound system equipement: Headphones and 
earphones associated with portable 
audio equipment – Maximum sound pressure level measurement methodology 
and limit considerations – Part 2: 
Guidelines to associate sets with headphones coming from different 
manufacturers.
 
Add the following notes for the standards indicated: 
 
IEC 60130 
NOTE 
Parts 9 and 17: 1998 are harmonized as Ens (not modified). 
IEC 60169  
NOTE   Partly harmonized in the EN 60169/HD 134 series (not modified). 
IEC 60173  
NOTE   Harmonized as HD 27 S1: 1978 (not modified). 
IEC 60335-2-56   NOTE 
Harmonized as EN 60335-2-56: 1997 (not modified). 
IEC 60335-2-82   NOTE   Harmonized as EN 60335-2-82: 2000 (not modified). 
IEC 60695  
NOTE   Harmonized as EN 60695 series (not modified). 
IEC 61040  
NOTE   Harmonized as EN 61040: 1992 (not modified). 
IEC 61558-2-1  
NOTE 
Harmonized as EN 61558-2-1: 1997 (not modified). 
IEC 61558-2-4  
NOTE   Harmonized as EN 61558-2-4: 1997 (not modified). 
IEC 61558-2-6 
NOTE   Harmonized as EN 61558-2-6: 1997 (not modified). 