JBL DUET II (serv.man7) EMC - CB Certificate ▷ View online
- Page 9 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.6 Power
interface
—
1.6.1
AC power distribution systems
DC supplied.
N/A
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7
Markings and instructions
—
1.7.1
Power rating
The required marking is located
on the outside surface of the
equipment.
on the outside surface of the
equipment.
P
Rated voltage(s) or voltage range(s) (V) ............:
18Vdc
—
Symbol for nature of supply, for d.c. only ............:
IEC 60417, symbol No. 5031, is
used.
used.
P
Rated frequency or rated frequency range (Hz) .:
DC supplied.
—
Rated current (mA or A) .....................................:
1200mA
—
Manufacturer’s name or trademark or
identification mark ...............................................:
identification mark ...............................................:
JBL
—
Type/model or type reference .............................:
Duet II
—
Symbol
of for Class II equipment only ................:
The equipment is Class III.
N/A
Other
symbols ....................................................:
The additional marking does
not give rise to
misunderstandings.
not give rise to
misunderstandings.
N/A
Certification
marks ..............................................:
Refer to copy of markings.
—
1.7.2 Safety
instructions
Class III equipment, the unit
can only be connected
to adapters list in the marking
label, refer to label.
can only be connected
to adapters list in the marking
label, refer to label.
P
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment .................................:
No voltage selector.
N/A
1.7.5
Power outlets on the equipment .........................:
No standard power outlet.
N/A
1.7.6 Fuse
identification ...............................................:
No fuse. N/A
1.7.7
Wiring terminals
Refer below:
—
1.7.7.1
Protective earthing and bonding terminals .........:
Class III equipment.
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
Class III equipment.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
Class III equipment.
N/A
1.7.8
Controls and indicators
Refer below:
—
- Page 10 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.8.1 Identification,
location
and marking ....................:
No control.
N/A
1.7.8.2 Colours
...............................................................:
No indicators with colours
where safety is involved.
where safety is involved.
N/A
1.7.8.3 Symbols
.............................................................:
There is no switch in the
equipment, function control is
marked with “+” and “-” for
volume control.
marked with “+” and “-” for
volume control.
N/A
1.7.8.4 Markings
using figures ......................................:
N/A
1.7.9
Isolation of multiple power sources ....................:
Class III equipment.
N/A
1.7.10
IT power distribution systems
Class III equipment.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12 Language
............................................................:
Instructions and markings shall
be in a language acceptable for
the country where the
equipment is to be used.
the country where the
equipment is to be used.
—
1.7.13
Durability
The marking withstands
required tests.
required tests.
P
1.7.14
Removable parts
No removable parts.
N/A
1.7.15
Replaceable batteries
No battery in the equipment.
N/A
Language.............................................................:
—
1.7.16
Operator access with a tool.................................:
All areas containing hazard(s)
are inaccessible to the
operator.
are inaccessible to the
operator.
N/A
1.7.17
Equipment for restricted access locations...........:
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2
PROTECTION FROM HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1
Access to energized parts
Class III equipment.
N/A
Test
by
inspection ...............................................:
N/A
Test
with
test finger ............................................:
N/A
Test
with
test pin .................................................:
N/A
Test
with
test probe ............................................:
N/A
2.1.1.2 Battery
compartments
........................................:
No TNV circuits in the
equipment.
equipment.
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N/A
- Page 11 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Working voltage (V); minimum distance (mm)
through insulation
through insulation
—
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N/A
2.1.1.5 Energy
hazards ..................................................:
Class III equipment, supplies
from a LPS, adaptor evaluated
in this test report (refer to
summary of testing)
from a LPS, adaptor evaluated
in this test report (refer to
summary of testing)
P
2.1.1.6
Manual controls
Class III equipment
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment
N/A
Time-constant
(s);
measured voltage (V)............:
—
2.1.2
Protection in service access areas
Class III equipment.
N/A
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2.2 SELV
circuits
—
2.2.1
General requirements
SELV limits are not exceeded
under normal condition and
after a single fault. Equipment
is powered by a SELV source.
under normal condition and
after a single fault. Equipment
is powered by a SELV source.
P
2.2.2
Voltages under normal conditions (V) .................:
Equipment is powered by a
SELV source.
SELV source.
P
2.2.3
Voltages under fault conditions (V) .....................:
Equipment is powered by a
SELV source.
SELV source.
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
Class III equipment.
N/A
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits .......: SELV circuits are not
connected to other circuits than
protective earth.
protective earth.
P
2.3 TNV
circuits
—
2.3.1 Limits
Refer
below:
—
Type of TNV circuits ............................................:
No TNV circuits in the
equipment.
equipment.
—
2.3.2
Separation from other circuits and from
accessible parts
accessible parts
No TNV circuits in the
equipment.
equipment.
N/A
Insulation
employed.............................................:
—
- Page 12 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.3.3
Separation from hazardous voltages
No TNV circuits in the
equipment.
equipment.
N/A
Insulation
employed.............................................:
—
2.3.4
Connection of TNV circuits to other circuits
No TNV circuits in the
equipment.
equipment.
N/A
Insulation
employed.............................................:
—
2.3.5
Test for operating voltages generated externally
No TNV circuits in the
equipment.
equipment.
N/A
2.4
Limited current circuits
—
2.4.1
General requirements
No limited current circuits.
N/A
2.4.2 Limit
values
—
Frequency
(Hz)....................................................:
—
Measured
current (mA) .......................................:
—
Measured
voltage (V) ..........................................:
—
Measured capacitance (
μF).................................:
—
2.4.3
Connection of limited current circuits to other
circuits
circuits
—
2.5
Limited power sources
—
Inherently limited output
Class III equipment powered by
Limited Power Source adaptor
certified by IEC 60950-1.
Therefore all outputs are
considered to be limited power.
(refer to summary of testing)
Limited Power Source adaptor
certified by IEC 60950-1.
Therefore all outputs are
considered to be limited power.
(refer to summary of testing)
N/A
Impedance limited output
N/A
Overcurrent protective device limited output
N/A
Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
N/A
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
power (VA)......................................................... :
power (VA)......................................................... :
—
Current rating of overcurrent protective device (A)
—
2.6
Provisions for earthing and bonding
—
Click on the first or last page to see other DUET II (serv.man7) service manuals if exist.