JBL DUET II (serv.man7) EMC - CB Certificate ▷ View online
- Page 29 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
S.2 Test
procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
(see 1.1.2)
P
Considered.
—
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
INSULATION (see 2.10.5.4)
N/A
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
—
V.1
Introduction
Class III equipment.
N/A
V.2
TN power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH
CURRENTS
CURRENTS
The equipment is not intended
connect to telecommunication
networks.
connect to telecommunication
networks.
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN
TRANSRORMER TESTS (see clause C.1)
TRANSRORMER TESTS (see clause C.1)
No transformer.
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT
CONDITIONING TEST (see 4.3.13.3)
CONDITIONING TEST (see 4.3.13.3)
No ultraviolet light.
N/A
- Page 30 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001, A11:2004)
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60950-1:2001, A11:2004)
P
General
C: Delete all the "country" notes in the reference
document according to the following list:
document according to the following list:
1.1.5
Note 2
1.5.8
Note 2
1.6.1 Note
1.7.2
Note 4
1.7.12
Note 2
2.1
Note
2.2.3
Note
2.2.4
Note
2.3.2 Note 2, 7, 8
2.3.3
Note 1, 2 2.3.4
Note 2,3 2.7.1 Note
2.10.3.1 Note 4
3.2.1.1 Note
3.2.3 Note 1, 2
3.2.5.1 Note 2
4.3.6
Note 1,2 4.7.2.2 Note
4.7.3.1 Note
2
6.1.2.1 Note
6.1.2.2 Note
6.2.2 Note
6.2.2.1 Note
2 6.2.2.2
Note
7 Note
4
7.1 Note
G2.1
Note 1, 2 Annex H Note 2
Considered.
—
1.2.4.1
S (DK): Certain types of Class I appliances (see
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
Class III equipment.
N/A
1.5.1
A (SE, Ordinance 1990:944) and
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
(CH, Ordinance on environmentally hazardous
substances SR 814.013, Annex 3.2, Mercury):
Add the following:
NOTE – Switches containing mercury such as thermostats,
relays and level controllers are not allowed.
relays and level controllers are not allowed.
There are no components
containing mercury in the
equipment.
containing mercury in the
equipment.
N/A
1.5.8
S (NO): Due to the IT power system used (see
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
annex V, Fig. V.7), capacitors are required to be
rated for the applicable line-to-line voltage
(230 V).
Class III equipment.
N/A
1.7.2
S (FI, NO, SE): C
LASS
I
PLUGGABLE EQUIPMENT
TYPE
A intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
connection to protective earth or if surge
suppressors are connected between the network
terminals and accessible parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
Class III equipment. The
adaptor is separately approved.
adaptor is separately approved.
N/A
FI: "Laite on liitettävä suojamaadoitus-
koskettimilla varustettuun pistorasiaan"
koskettimilla varustettuun pistorasiaan"
N/A
NO: "Apparatet må tilkoples jordet stikkontakt"
N/A
SE: "Apparaten skall anslutas till jordat uttag"
N/A
A (DK, Heavy Current Regulations): Supply cords
of
of
CLASS
I
EQUIPMENT
, which is delivered without
a plug, must be provided with a visible tag with
the following text:
Vigtigt!
the following text:
Vigtigt!
N/A
- Page 31 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
Lederen med grøn/gul isolation må kun tilsluttes
en klemme mærket
en klemme mærket
eller
If essential for the safety of the equipment, the
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
tag must in addition be provided with a diagram
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
1.7.5
S (DK): Socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY
EQUIPMENT
the socket-outlet shall be
in accordance with Standard Sheet DK 1-1b or
DK 1-5a.
DK 1-5a.
There are no socket outlets
providing power to other
appliances.
providing power to other
appliances.
N/A
1.7.5
A (DK, Heavy Current Regulations):
CLASS
II
EQUIPMENT
shall not be fitted with socket-
outlets for providing power to other equipment.
Class III equipment.
N/A
1.7.12
A (DE, Gesetz über technische Arbeitsmittel
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
rd
October 1992, Article 3, 3
rd
paragraph, 2
nd
sentence, together with the "Allgemeine
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on
the execution of the Second Section of the
Equipment safety law], of 10
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on
the execution of the Second Section of the
Equipment safety law], of 10
th
January 1996,
article 2, 4
th
paragraph item 2).
Directions for use with rules to prevent certain
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
NOTE: Of this requirement, rules for use even only by service
personnel are not exempted.
personnel are not exempted.
Must be considered before
marketed in Germany.
marketed in Germany.
N/A
1.7.15
A (CH, Ordinance on environmentally hazardous
substances SR 814.013):
Annex 4.10 of SR 814.013 applies for batteries.
substances SR 814.013):
Annex 4.10 of SR 814.013 applies for batteries.
There is no battery containing
Cd or Hg in the equipment.
Cd or Hg in the equipment.
N/A
A (DE, Regulation on protection against hazards
by X-ray, of 8
by X-ray, of 8
th
January 1987, Article 5
[Operation of X-ray emission source], clauses 1
to 4):
a) A licence is required by those who operate an
X-ray emission source.
b) A licence in accordance with clause 1 is not
to 4):
a) A licence is required by those who operate an
X-ray emission source.
b) A licence in accordance with clause 1 is not
The unit does not emit X-ray
radiation.
radiation.
N/A
- Page 32 of 51 -
www.nemko.com
Report No. 114383
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1, A11
Clause
Requirement – Test
Result – Remark
Verdict
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 μSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
c) A licence in accordance with clause 1 is also
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
d) Furthermore, a licence in accordance with
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe
CRT.
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 μSv/h and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
c) A licence in accordance with clause 1 is also
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
d) Furthermore, a licence in accordance with
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe
CRT.
2.2.4
S (NO): Requirements according to this annex,
1.7.2 and 6.1.2.1 apply.
1.7.2 and 6.1.2.1 apply.
No TNV circuits.
N/A
2.3.2
S (NO): Requirements according to this annex,
6.1.2.1 apply.
6.1.2.1 apply.
No TNV circuits.
N/A